Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Yuhang jice jishu

Design of A Downsized Spectrum Lamp

Sheng Rong-wu

Published Jan 1, 2008• 1 citation
OpenAlex

Abstract

The downsized spectrum lamp is one of the key points of the miniature passive Rubidium Frequency Standards(RFS).As a complex compound,the lamp is divided into four aspects which include mechanical structure,thermal distribution,electromagnetic radiation and exciting circuit scheme.According to the result of compute simulation and parameters optimization a downsized lamp is designed and result in good performance as followed:volume14mL,lamp temperature115 ℃,exciting current80 mA,light drift1·10-4/day,light sensitivity1·10-3/℃.This downsized spectrum lamp have been used successfully in the miniature RFS.

Related papers

The effect of RF excitation frequency on the spectrum characteristics of rubidium electrodeless lamp

Weiwei Wang, Lijun Du, Rongyan Zhang +2 more

Rubidium electrodeless lamp is one of the core components of rubidium atomic frequency standard. It plays the role of optical pumping and quantum state preparation, and realizes the particle number inversion between two ground states of rubidium atoms. The RF excitation frequency affects the effective light spectral distribution of rubidium electrodeless lamp, and then determines the pumping efficiency and the limiting frequency stability of rubidium atomic frequency standard. In this paper, the influence of RF excitation frequency on the spectral characteristics of rubidium electrodeless lamp can be optimized based on power compensation. It is found that there is a sensitive dependence between the heating rate and the excitation frequency of the rubidium electrodeless lamp, and the excitation frequency range corresponding to the turning point of the maximum heating rate was given experimentally. When the input power and the bubble wall temperature remain unchanged and the rubidium electrodeless lamp is in the ring-mode state, the spectral characteristics have a depression at the optimum resonance frequency. Therefore, the excitation frequency of the rubidium electrodeless lamp should be properly pulled to 5~9 MHz from the optimum resonant point, which can optimize the spectral characteristics of the rubidium electrodeless lamp and can improve the frequency stability of the rubidium atomic clock.

Sixth Symposium on Novel Optoelectronic Detection Technology and Applications•Apr 17, 2020•0 citations

[Spectroscopy study of rubidium spectrum lamps].

Fang Wang, Feng Lin Zhao, Feng Qi +3 more

Rubidium spectral lamp is one of the critical parts in a rubidium atomic frequency standard (RAFS). The light emitted from the spectral lamp contains two components, one is the useful component, which contributes to the atomic transition signal, and the other is the useless component, which acts only as the light noise. In order to improve the signal-to-noise ratio of the frequency locking loop of a RAFS, and therefore to obtain a highly stable RAFS, it's very important to enhance the useful light component and suppress the useless component. In the present work the light spectra of the three commonly used rubidium spectrum lamps with bulbs separately filled with buffer gases argon, krypton and xenon were obtained by means of a monochromator. The spectra were analyzed and the methods to enhance useful light intensity and reduce useless light intensity were discussed. Results showed that the useful light intensity strongly depends on the types of buffer gases and the bulb temperature. In the whole range of bulb temperature, the Xe lamp had the highest useful light intensity among the three lamps. The Kr lamp showed a higher useful light intensity than the Ar lamp at low bulb temperature, while at high bulb temperature the Ar lamp showed a higher useful light intensity than the Kr lamp. Analysis also indicates that the light noise of a rubidium spectrum lamp can be effectively minimized by adopting suitable light filtering technique.

•May 1, 2009•0 citations

Characterisation of Rubidium Vapour Lamps for Atomic Clocks

Ulas Sabahattin Gokay, Nitika Gupta, Rabia Ince +3 more

Since the 1960s, alkali-based RF discharge lamps have been used as frequency-stable light sources due to their reliable performance [1]. However, it is often reported that rubidium (Rb) lamp-based standards suffer from lamp-related frequency ageing phenomena such as light-shift effects [2], [3]. To understand this behaviour, we are characterising a commercial Rb-based RF discharge lamp over extended periods and will present an analysis of data collected so far. Electrical and optical measurements on a Rb lamp are presented here after about 40 days of monitoring. The output of the lamp was coupled into an optical fibre to observe its emitted light characteristics with an optical spectrum analyser. Optical spectra results indicated that the lamp had substantial buffer gas content. The lamp spectra exhibited various buffer gas excitation lines as well as strong Rb excitation lines of 780.0 nm (D2 line) and 794.8 nm (D1 line). Subsequently, the lamp was monitored for output optical power, temperature, and electric current dynamics in a laboratory environment. During monitoring, sudden changes in light output were observed along with longer term trends. From previous studies, we can expect that temporal changes in the light intensity of the lamps may lead to observable frequency fluctuations in an atomic clock [4].

European Frequency and Time Forum•Jun 25, 2024•0 citations

Composite-type Rb-87 optical-pumping light source for the rubidium frequency standard

N. Oura, Naimu Kuramochi, Shigeya Naritsuka +1 more

This paper describes the experimental results and theoretical analysis of a newly devised compact light source for the Rubidium Frequency Standard (RFS). The light source is composed of a cylindrical Rb-87 lamp 10 mm diameter and a Rb-85 filter cell 3-7 mm long attached to the front flat face of the lamp. This composite-type device is operated in an oven at about 100-deg C. Thus a light source for Rb-87 hyperfine optical pumping less than 4 cm long by 3 cm diameter has been constructed.

•Mar 1, 1982•2 citations

A Miniature Cavity-Cell Assembly for Rubidium Atomic Frequency Standards and Its Frequency Shift Characteristics

Baihua Xia, Da Zhong

The structure and frequency shift characteristics of a new kind of miniature cavity-cell assembly for rubidium atomic frequency standards (RAFS) are reported. The cavity pull effect, microwave power shift, light shift and temperature coefficient which mostly influence the performance of RAFS are studied. The results indicate that the influences are controlled in an acceptable range. The cavity-cell assembly is of small size and high signal to noise ratio. The parameters of the assembly could be conveniently optimized. This cavity-cell assembly can be used to make a miniaturized rubidium atomic frequency standard with high performance.

Jiliang xuebao•Jan 1, 2005•2 citations

Mercury spectrum lamp property analysis and parameter optimization

Huili Shao, Yonghui Xie, Yue Liang +2 more

Mercury spectrum lamp is an important part of Mercury Atomic Frequency Standard (MAFS), which is used for light pumping and state detection. It may limit the stability and the signal-to-noise ratio performance in MAFS. In this work, we experimentally demonstrate mercury spectrum lamp can work under an optimum mode by controlling the cold end temperature of the lamp. It is found the maximum radiation intensity at 194[Formula: see text]nm and the minimal 254[Formula: see text]nm/194[Formula: see text]nm ratio can be achieved simultaneously at about 55∘C. The minimal 254[Formula: see text]nm/194[Formula: see text]nm is about 24, which is an order of magnitude lower than the case in common. Meanwhile, the effect of RF excitation power on 254[Formula: see text]nm/194[Formula: see text]nm ratio and the self-absorption phenomenon of 254[Formula: see text]nm are also investigated. The result demonstrates RF excitation power has a stronger influence on the light intensity of 194[Formula: see text]nm than on that of 254[Formula: see text]nm. These experimental results could shed light on later fluorescence detection experiment in MAFS and other lamp-based applications.

International Journal of Modern Physics B•Jul 17, 2023•0 citations
The downsized spectrum lamp is one of the key points of the miniature passive Rubidium Frequency Standards(RFS).As a complex compound,the lamp is divided into four aspects which include mechanical structure,thermal distribution,electromagnetic radiation and exciting circuit scheme.According to the result of compute simulation and parameters optimization a downsized lamp is designed and result in good performance as followed:volume14mL,lamp temperature115 ℃,exciting current80 mA,light drift1·10-4/day,light sensitivity1·10-3/℃.This downsized spectrum lamp have been used successfully in the miniature RFS.
Rubidium electrodeless lamp is one of the core components of rubidium atomic frequency standard. It plays the role of optical pumping and quantum state preparation, and realizes the particle number inversion between two ground states of rubidium atoms. The RF excitation frequency affects the effective light spectral distribution of rubidium electrodeless lamp, and then determines the pumping efficiency and the limiting frequency stability of rubidium atomic frequency standard. In this paper, the influence of RF excitation frequency on the spectral characteristics of rubidium electrodeless lamp can be optimized based on power compensation. It is found that there is a sensitive dependence between the heating rate and the excitation frequency of the rubidium electrodeless lamp, and the excitation frequency range corresponding to the turning point of the maximum heating rate was given experimentally. When the input power and the bubble wall temperature remain unchanged and the rubidium electrodeless lamp is in the ring-mode state, the spectral characteristics have a depression at the optimum resonance frequency. Therefore, the excitation frequency of the rubidium electrodeless lamp should be properly pulled to 5~9 MHz from the optimum resonant point, which can optimize the spectral characteristics of the rubidium electrodeless lamp and can improve the frequency stability of the rubidium atomic clock.
Rubidium spectral lamp is one of the critical parts in a rubidium atomic frequency standard (RAFS). The light emitted from the spectral lamp contains two components, one is the useful component, which contributes to the atomic transition signal, and the other is the useless component, which acts only as the light noise. In order to improve the signal-to-noise ratio of the frequency locking loop of a RAFS, and therefore to obtain a highly stable RAFS, it's very important to enhance the useful light component and suppress the useless component. In the present work the light spectra of the three commonly used rubidium spectrum lamps with bulbs separately filled with buffer gases argon, krypton and xenon were obtained by means of a monochromator. The spectra were analyzed and the methods to enhance useful light intensity and reduce useless light intensity were discussed. Results showed that the useful light intensity strongly depends on the types of buffer gases and the bulb temperature. In the whole range of bulb temperature, the Xe lamp had the highest useful light intensity among the three lamps. The Kr lamp showed a higher useful light intensity than the Ar lamp at low bulb temperature, while at high bulb temperature the Ar lamp showed a higher useful light intensity than the Kr lamp. Analysis also indicates that the light noise of a rubidium spectrum lamp can be effectively minimized by adopting suitable light filtering technique.
Since the 1960s, alkali-based RF discharge lamps have been used as frequency-stable light sources due to their reliable performance [1]. However, it is often reported that rubidium (Rb) lamp-based standards suffer from lamp-related frequency ageing phenomena such as light-shift effects [2], [3]. To understand this behaviour, we are characterising a commercial Rb-based RF discharge lamp over extended periods and will present an analysis of data collected so far. Electrical and optical measurements on a Rb lamp are presented here after about 40 days of monitoring. The output of the lamp was coupled into an optical fibre to observe its emitted light characteristics with an optical spectrum analyser. Optical spectra results indicated that the lamp had substantial buffer gas content. The lamp spectra exhibited various buffer gas excitation lines as well as strong Rb excitation lines of 780.0 nm (D2 line) and 794.8 nm (D1 line). Subsequently, the lamp was monitored for output optical power, temperature, and electric current dynamics in a laboratory environment. During monitoring, sudden changes in light output were observed along with longer term trends. From previous studies, we can expect that temporal changes in the light intensity of the lamps may lead to observable frequency fluctuations in an atomic clock [4].
The structure and frequency shift characteristics of a new kind of miniature cavity-cell assembly for rubidium atomic frequency standards (RAFS) are reported. The cavity pull effect, microwave power shift, light shift and temperature coefficient which mostly influence the performance of RAFS are studied. The results indicate that the influences are controlled in an acceptable range. The cavity-cell assembly is of small size and high signal to noise ratio. The parameters of the assembly could be conveniently optimized. This cavity-cell assembly can be used to make a miniaturized rubidium atomic frequency standard with high performance.
Mercury spectrum lamp is an important part of Mercury Atomic Frequency Standard (MAFS), which is used for light pumping and state detection. It may limit the stability and the signal-to-noise ratio performance in MAFS. In this work, we experimentally demonstrate mercury spectrum lamp can work under an optimum mode by controlling the cold end temperature of the lamp. It is found the maximum radiation intensity at 194[Formula: see text]nm and the minimal 254[Formula: see text]nm/194[Formula: see text]nm ratio can be achieved simultaneously at about 55∘C. The minimal 254[Formula: see text]nm/194[Formula: see text]nm is about 24, which is an order of magnitude lower than the case in common. Meanwhile, the effect of RF excitation power on 254[Formula: see text]nm/194[Formula: see text]nm ratio and the self-absorption phenomenon of 254[Formula: see text]nm are also investigated. The result demonstrates RF excitation power has a stronger influence on the light intensity of 194[Formula: see text]nm than on that of 254[Formula: see text]nm. These experimental results could shed light on later fluorescence detection experiment in MAFS and other lamp-based applications.