Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

High-Resolution Digital SQUID Magnetometer using Sub-Flux Quantum Feedback

Hiroaki Myoren, Kosuke Okabe, Ryo Matsunawa, Kohki Itagaki, Masato Naruse, Tohru Taino

Published Jun 1, 2020• 0 citations
Publisher

Abstract

Abstract Digital SQUIDs with the single flux quantum (SFQ) feedback have attracted much attention because of the feasibility of realizing a wide dynamic range and high slew rate for digital magnetometers. In order to realize higher resolution, we have studied a digital SQUID with sub-flux quantum feedback. Combining the sub-flux quantum feedback to a feedback loop and the direct SFQ feedback to a main loop triggered by carry SFQ pulses from an up/down counter. In this study, we discuss the method of multi-flux quantum generation and compact design of the SFQ up/down counter for high-speed operation of the digital SQUID magnetometer.

DOI
10.1088/1742-6596/1559/1/012013

Related papers

Design and Performance of Digital SQUID with Sub-Flux Quantum Resolution

Hiroaki Myoren, Kouhei Takatoku, Masato Naruse +1 more

Digital SQUIDs based on the single flux quantum (SFQ) logic have attractive characteristics, such as wide dynamic range and high slew rate. However, the resolution of digital SQUIDs is limited to SFQ. To realize sub-flux quantum resolution for these SQUIDs, we have adopted two types of feedback combinations: one with the SFQ input/output for a main loop and the other with a mutually coupled loop. The main loop receives direct Φ0feedback and sub-flux quantum feedback Φ0/n, where n is an integer, from the mutually coupled loop. We confirmed the correct operation of our device at a clock frequency of 1.25 GHz for a digital SQUID with a sub-Φ0flux feedback resolution of Φ0/8 from circuit simulation. The slew rate is found to be 1.56×108Φ0/s in this simulation (fc=1.25 GHz, n=8). The flux resolution for the digital SQUID shows improvement with increasing n and reached below 40 mΦ0with n=210; however the slew rate is decreased with increasing n and reached 1.22×106Φ0/swith fc=1.25 GHz and n=210.

IEEE International Superconductive Electronics Conference (ISEC)•Jul 1, 2015•2 citations

Performance of Digital SQUID with Sub-Flux Quantum Feedback Resolution Fabricated using 10 kA/cm2 Nb Process

Kohki Itagaki, Itta Oshima, Yuichi Hasegawa +4 more

Abstract Digital superconducting quantum interference device (SQUID with Single Flux Quantum (SFQ) feedback operates as a Δ-type oversampling A/D converter. Magnetic flux resolution at Nyquist frequency can be improved by taking sub SFQ feedback resolution and large oversampling ratio. Using high critical current density Nb process for fabricating SFQ circuits, we expected more higher operation speed for the digital SQUID and resulting to higher magnetic flux resolutions. We expected a performance of the digital SQUID magnetometer fabricated using 10 kA/cm2 Nb process based on CAD layout, with an up/down counter using T2FF cells and parallel SFQ feedback. For the clock frequency of 13 GHz and the Nyquist frequency of 1.587 MHz, the magnetic field noise was lower than 1.5 fT / Hz and the slew rate was exceeded 500 mT/s.

Journal of Physics Conference Series•Jul 1, 2020•0 citations

Design and Magnetic Field Noise of Magnetometer Using Digital SQUID With Subflux Quantum Feedback

Hiroaki Myoren, Kouhei Takatoku, Masato Naruse +1 more

Digital superconducting quantum interference devices (SQUIDs) based on single-flux quantum (SFQ) logic have attractive characteristics such as wide dynamic ranges and high slew rates. However, the resolution of a typical digital SQUID is limited by SFQ feedback. To realize lower magnetic field noise by magnetometers using digital SQUIDs, we have adopted two feedback combinations: one, utilizing the SFQ input/output for a main loop and the other, using a mutually coupled loop. The main loop receives direct Φ0feedback and subflux quantum feedback Φ0/n, where n is an integer from the mutually coupled loop. The flux resolution for the digital SQUID shows improvement with increasing n and reaches below 40 mΦ0at n = 210; however, the slew rate decreases with increasing n and reaches 1.22 × 106Φ0/s at fc= 1.25 GHz and n = 210. For a magnetometer using a digital SQUID with a pickup loop, we confirmed a magnetic field noise of less than 100 fT/√Hz with a signal bandwidth of 1 MHz for operation frequency fcof 20 GHz.

IEEE Transactions on Applied Superconductivity•May 20, 2016•7 citations

Characterization of a digital squid for magnetic field measurements with high dynamic range

Imke Haverkamp, Olaf Wetzstein, J. Kunert +3 more

Measurements of extremely weak magnetic fields in unshielded environments require sensors providing a high dynamic range and slew rate while maintaining a high resolution. At present, analog Superconducting Quantum Interference Devices (SQUIDs) are the most sensitive sensors for magnetic flux. Due to their room-temperature feedback electronics necessary to maintain a stable point of operation, slew rates of those sensors are limited. The dynamic range is usually restricted by the resolution of classical analog to digital converters. The digital SQUID follows a different approach: a change of the magnetic field penetrating the pickup loop is translated by the sensor into a stream of voltage pulses. Each pulse represents the change of the magnetic flux inside the pickup loop by one flux quantum Φ0. By fast counting of these flux quanta, it is possible to outperform the analog SQUID in terms of dynamic range and maximum slew rate. We present our latest results with respect to the internal mechanisms of the digital SQUID and present a method to compensate the main source for nonlinear behavior of the sensor. The analyzed circuit was fabricated by FLUXONICS Foundry (1) in a 1 kA/cm² niobium fabrication process.

Elektronika : konstrukcje, technologie, zastosowania•Jan 1, 2011•1 citation

Design of Digital DROS With SFQ Up/Down Counter for Wide Dynamic Operation Range

Hiroaki Myoren, Kimimoto Yun, Kosuke Terui +1 more

We designed a digital double relaxation oscillation SQUID (DROS) with an SFQ up/down counter. The DROS is connected to a feedback SQUID loop and a signal magnetic flux is input to the feedback SQUID loop. The DROS generates two kinds of voltage pulses corresponding to the total magnetic flux in the feedback SQUID loop. Two kind of voltage pulses are converted to SFQ and anti-SFQ pulses and input to the feedback SQUID loop to keep the magnetic flux in the SQUID loop constant. The number of the generated SFQ pulses is counted using the SFQ up/down counter. Thus, the count corresponds to the input magnetic flux. Because the SFQ up/down counter is operated in the pulse driven mode, the digital DROS needs only dc bias current for operation. We designed and fabricated a digital DROS with a relaxation oscillation frequency of 3 GHz and an 8-bit SFQ up/down counter. Numerical simulation suggested the designed digital DROS has a dynamic range exceeding ±100 Φ0and magnetic flux slew rate of 3 × 109Φ0/s.

IEEE Transactions on Applied Superconductivity•Jan 28, 2011•15 citations

[INVITED] Digital magnetometers based on the Single-Flux-Quantum technique

Pascal Febvre, Stolz, Ronny, Meyer, Hans-Georg +5 more

Superconducting Quantum Interference Devices (SQUIDs) are known to be the most sensitive magnetometers. We present a new type of low-Tc digital SQUID that is based on Rapid-Single-Flux-Quantum (RSFQ) Logic. It allows the on-chip conversion of the detected magnetic field into a digital form, suitable for noiseless processing, very high dynamic range and high slew rate. The sensitivity, limited to one magnetic single flux quantum, and a dynamic range of 76 dB, that corresponds to an upper limit of the magnetic field amplitude higher than 5 μT, have been measured along with overnight stability. First signatures of magnetic fields have been observed simultaneously with the ones of analogue SQUIDs in the ultra low noise environment of the Laboratoire Souterrain à Bas Bruit (LSBB) located in Rustrel, Provence, France.

•Jun 15, 2009•0 citations
Abstract Digital SQUIDs with the single flux quantum (SFQ) feedback have attracted much attention because of the feasibility of realizing a wide dynamic range and high slew rate for digital magnetometers. In order to realize higher resolution, we have studied a digital SQUID with sub-flux quantum feedback. Combining the sub-flux quantum feedback to a feedback loop and the direct SFQ feedback to a main loop triggered by carry SFQ pulses from an up/down counter. In this study, we discuss the method of multi-flux quantum generation and compact design of the SFQ up/down counter for high-speed operation of the digital SQUID magnetometer.
Digital SQUIDs based on the single flux quantum (SFQ) logic have attractive characteristics, such as wide dynamic range and high slew rate. However, the resolution of digital SQUIDs is limited to SFQ. To realize sub-flux quantum resolution for these SQUIDs, we have adopted two types of feedback combinations: one with the SFQ input/output for a main loop and the other with a mutually coupled loop. The main loop receives direct Φ0feedback and sub-flux quantum feedback Φ0/n, where n is an integer, from the mutually coupled loop. We confirmed the correct operation of our device at a clock frequency of 1.25 GHz for a digital SQUID with a sub-Φ0flux feedback resolution of Φ0/8 from circuit simulation. The slew rate is found to be 1.56×108Φ0/s in this simulation (fc=1.25 GHz, n=8). The flux resolution for the digital SQUID shows improvement with increasing n and reached below 40 mΦ0with n=210; however the slew rate is decreased with increasing n and reached 1.22×106Φ0/swith fc=1.25 GHz and n=210.
Abstract Digital superconducting quantum interference device (SQUID with Single Flux Quantum (SFQ) feedback operates as a Δ-type oversampling A/D converter. Magnetic flux resolution at Nyquist frequency can be improved by taking sub SFQ feedback resolution and large oversampling ratio. Using high critical current density Nb process for fabricating SFQ circuits, we expected more higher operation speed for the digital SQUID and resulting to higher magnetic flux resolutions. We expected a performance of the digital SQUID magnetometer fabricated using 10 kA/cm2 Nb process based on CAD layout, with an up/down counter using T2FF cells and parallel SFQ feedback. For the clock frequency of 13 GHz and the Nyquist frequency of 1.587 MHz, the magnetic field noise was lower than 1.5 fT / Hz and the slew rate was exceeded 500 mT/s.
Digital superconducting quantum interference devices (SQUIDs) based on single-flux quantum (SFQ) logic have attractive characteristics such as wide dynamic ranges and high slew rates. However, the resolution of a typical digital SQUID is limited by SFQ feedback. To realize lower magnetic field noise by magnetometers using digital SQUIDs, we have adopted two feedback combinations: one, utilizing the SFQ input/output for a main loop and the other, using a mutually coupled loop. The main loop receives direct Φ0feedback and subflux quantum feedback Φ0/n, where n is an integer from the mutually coupled loop. The flux resolution for the digital SQUID shows improvement with increasing n and reaches below 40 mΦ0at n = 210; however, the slew rate decreases with increasing n and reaches 1.22 × 106Φ0/s at fc= 1.25 GHz and n = 210. For a magnetometer using a digital SQUID with a pickup loop, we confirmed a magnetic field noise of less than 100 fT/√Hz with a signal bandwidth of 1 MHz for operation frequency fcof 20 GHz.
Measurements of extremely weak magnetic fields in unshielded environments require sensors providing a high dynamic range and slew rate while maintaining a high resolution. At present, analog Superconducting Quantum Interference Devices (SQUIDs) are the most sensitive sensors for magnetic flux. Due to their room-temperature feedback electronics necessary to maintain a stable point of operation, slew rates of those sensors are limited. The dynamic range is usually restricted by the resolution of classical analog to digital converters. The digital SQUID follows a different approach: a change of the magnetic field penetrating the pickup loop is translated by the sensor into a stream of voltage pulses. Each pulse represents the change of the magnetic flux inside the pickup loop by one flux quantum Φ0. By fast counting of these flux quanta, it is possible to outperform the analog SQUID in terms of dynamic range and maximum slew rate. We present our latest results with respect to the internal mechanisms of the digital SQUID and present a method to compensate the main source for nonlinear behavior of the sensor. The analyzed circuit was fabricated by FLUXONICS Foundry (1) in a 1 kA/cm² niobium fabrication process.
We designed a digital double relaxation oscillation SQUID (DROS) with an SFQ up/down counter. The DROS is connected to a feedback SQUID loop and a signal magnetic flux is input to the feedback SQUID loop. The DROS generates two kinds of voltage pulses corresponding to the total magnetic flux in the feedback SQUID loop. Two kind of voltage pulses are converted to SFQ and anti-SFQ pulses and input to the feedback SQUID loop to keep the magnetic flux in the SQUID loop constant. The number of the generated SFQ pulses is counted using the SFQ up/down counter. Thus, the count corresponds to the input magnetic flux. Because the SFQ up/down counter is operated in the pulse driven mode, the digital DROS needs only dc bias current for operation. We designed and fabricated a digital DROS with a relaxation oscillation frequency of 3 GHz and an 8-bit SFQ up/down counter. Numerical simulation suggested the designed digital DROS has a dynamic range exceeding ±100 Φ0and magnetic flux slew rate of 3 × 109Φ0/s.
Superconducting Quantum Interference Devices (SQUIDs) are known to be the most sensitive magnetometers. We present a new type of low-Tc digital SQUID that is based on Rapid-Single-Flux-Quantum (RSFQ) Logic. It allows the on-chip conversion of the detected magnetic field into a digital form, suitable for noiseless processing, very high dynamic range and high slew rate. The sensitivity, limited to one magnetic single flux quantum, and a dynamic range of 76 dB, that corresponds to an upper limit of the magnetic field amplitude higher than 5 μT, have been measured along with overnight stability. First signatures of magnetic fields have been observed simultaneously with the ones of analogue SQUIDs in the ultra low noise environment of the Laboratoire Souterrain à Bas Bruit (LSBB) located in Rustrel, Provence, France.