Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

APS

SQUID Multiplexing Circuit for Readout of Superconducting Bolometric Arrays

James A. Chervenak, Erich N. Grossman, K. D. Irwin, J. M. Nartinis, C. D. Reintsema, M. E. Huber, S. H. Moseley, Christine A. Allen

Published Mar 1, 1998• 0 citations
OpenAlex

Related papers

Superconducting NbSi Bolometric Array And SQUID with Cryogenic SiGe Integrated Circuit

D. Prêle, É. Bréelle, M. Piat +12 more

•Mar 30, 2008•0 citations

Very-low-noise multiplexing with SQUIDs and SiGe HBTs for readout of large superconducting bolometer arrays

D. Prêle, G. Klisnick, G. Sou +4 more

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Jun 5, 2007•5 citations

Integrated Circuit Operating at 4.2 K for Time Domain SQUID Multiplexing of Superconducting Bolometer Array

D. Prêle, Fabrice Voisin, G. Sou +4 more

•Jun 22, 2008•0 citations

Microwave SQUID multiplexer for readout of optical TES array

Naoki Nakada, Hattori Kaori, Yuki Nakashima +7 more

IEICE Technical Report; IEICE Tech. Rep.•Aug 2, 2019•0 citations

A Time-Domain SQUID multiplexer for readout of x-ray microcalorimeter arrays

William Bertrand Doriese, J. A. Beall, Joern Beyer +9 more

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Jan 1, 2004•3 citations

A microwave SQUID multiplexer optimized for bolometric applications

B. Dober, Zeeshan Ahmed, K. Arnold +27 more

A microwave superconducting quantum interference device multiplexer has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4–8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4–5 GHz. The median white-noise level is 45 pA/Hz, evaluated at 2 Hz, with a 1/f knee ≤ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is ≤ 0.3%.

arXiv:2010.07998•Applied Physics Letters•Feb 8, 2021•56 citations
A microwave superconducting quantum interference device multiplexer has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4–8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4–5 GHz. The median white-noise level is 45 pA/Hz, evaluated at 2 Hz, with a 1/f knee ≤ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is ≤ 0.3%.