Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Softwaretechnik-Trends

Increased bandwidth of NbN phonon cooled hot electron bolometer mixers

Merlijn Hajenius, J. J. A. Baselmans, J. R. Gao, T. M. Klapwijk, Piet A. J. de Korte, B. Voronov, Gregory N Gol'tsman

Published Jan 1, 2004• 2 citations
OpenAlex

Related papers

Large Bandwidth Of Nbn Phonon-cooled Hot-electron Bolometer Mixers.

S. Cherednichenko, Pavel A. Yagoubov, K. ll'in +2 more

European Microwave Conference (EuMC)•Aug 24, 2005•2 citations

NbN Phonon-Cooled Hot-Electron Bolometer Mixer with Additional Diffusion Cooling

Рябчун Сергей Александрович, Ivan V. Tretyakov, Matvey I. Finkel +5 more

•Apr 1, 2009•3 citations

Mixer Performance Degradation Due to Contact Resistance in NbN Phonon-cooled Hot-electron Bolometers

H. Merke, P. Khosropanah, K. S. Yngvesson +4 more

•Dec 1, 2001•0 citations

Improvement of Phonon Diffusion Efficiency in Phonon-Cooled NbN Hot Electron Bolometer Mixers

Shigehito Miki, Akira Kawakami, Yoshinori Uzawa +1 more

We propose a superconducting hot electron bolometer (HEB) mixer with an upper heat sink to improve the phonon diffusion efficiency in phonon cooled HEB mixers. We designed and fabricated NbN HEB mixers, and investigated the cooling effect of the upper heat sink by measuring intermediate frequency (IF) bandwidths of the HEB mixers. The SiO films for the upper dielectric heat sink, ranging in thickness from 9 to 35 µm, were deposited on the top of the NbN strip by high vacuum evaporation. We measured the IF bandwidths of HEB mixers, with and without the SiO heat sink, and observed that the 3-dB IF roll-off frequency increased from 0.4 to 0.7 GHz by using a 35-µm-thick SiO heat sink.

Japanese Journal of Applied Physics•Jun 15, 2003•3 citations

Comparative Study of the Bandwidth of Phonon-Cooled NbN Hot-Electron Bolometers in Submillimeter and Optical Wavelength Ranges

K. Ilin, Serguei Cherednichenko, Gregory N Gol'tsman +2 more

We report the results of the bandwidth measurements of NbN hot-electron bolometers, perfomied in the terahertz frequency domain at 140 GHz and 660 GHz and in time domain in the optical range at the wavelength of 395 nm.. Our studies were done on 3.5-nm-thick NbN films evaporated on sapphire substrates and patterned into ilin-size microbridges. In order to measure the gain bandwidth, we used two identical BWOs (140 or 660 GHz), one functioning as a local oscillator and the other as a signal source. The bandwidth we achieved was 3.5-4 GHz at 4.2 K with the optimal LO and DC biases. Time-domain measurements with a resolution below 300 fs were performed using an electro-optic sampling system, in the temperature range between 4.2 K to 9 K at various values of the bias current and optical power. The obtained response time of the NbN hot-electron bolometer to —100fs-wide Ti:sapphire laser pulses was about 27 ps, what corresponds to the 5.9 GHz gain bandwidth. Introduction The bandwidth of hot-electron bolometer (HEB) mixers has reached values which are record for bolometers. The gain bandwidth for phonon-cooled NbN HEB mixers of 4 GHz for 140 GHz and 650 GHz frequencies [1, 2] and the noise bandwidth of 8 GHz for 650 GHz [2] have been demonstrated. For diffusion-cooled Nb HEB mixers, the bandwidth has reached 6 GHz, when measured at 20--40 GHz [3]. However, there is a definite practical interest to even further extend the bandwidth of these devices. The possibilities of the HEB mixer technology in this direction are far from being exhausted. For example, the future of the NbN HEB technology requires that critical temperature Tc > 10 K and critical current density j c > 10 6 Akm at 4.2 K are simultaneously obtained for d < 3 nm-thick films M. The reduction of the optimal power of the local oscillator PLID below 100 nW leads to the decrease of the device length down to L < 0.2 pm, which, in turn, should bring an additional cooling channel for hot electrons—diffusion into metal contacts and a further bandwidth extension.

Softwaretechnik-Trends•Mar 1, 1998•0 citations

Low noise and wide bandwidth of NbN hot-electron bolometer mixers

Ivan V. Tretyakov, Рябчун Сергей Александрович, Matvey I. Finkel +5 more

We report a record double sideband noise temperature of 600 K (5hν/kB) offered by a NbN hot-electron bolometer receiver at 2.5 THz. Allowing for standing wave effects, this value was found to be constant in the intermediate frequency range 1–7 GHz, which indicates that the mixer has an unprecedentedly large noise bandwidth in excess of 7 GHz. The insight into this is provided by gain bandwidth measurements performed at the superconducting transition. They show that the dependence of the bandwidth on the mixer length follows the model for an HEB mixer with diffusion and phonon cooling of the hot electrons.

Applied Physics Letters•Jan 17, 2011•77 citations
We propose a superconducting hot electron bolometer (HEB) mixer with an upper heat sink to improve the phonon diffusion efficiency in phonon cooled HEB mixers. We designed and fabricated NbN HEB mixers, and investigated the cooling effect of the upper heat sink by measuring intermediate frequency (IF) bandwidths of the HEB mixers. The SiO films for the upper dielectric heat sink, ranging in thickness from 9 to 35 µm, were deposited on the top of the NbN strip by high vacuum evaporation. We measured the IF bandwidths of HEB mixers, with and without the SiO heat sink, and observed that the 3-dB IF roll-off frequency increased from 0.4 to 0.7 GHz by using a 35-µm-thick SiO heat sink.
We report the results of the bandwidth measurements of NbN hot-electron bolometers, perfomied in the terahertz frequency domain at 140 GHz and 660 GHz and in time domain in the optical range at the wavelength of 395 nm.. Our studies were done on 3.5-nm-thick NbN films evaporated on sapphire substrates and patterned into ilin-size microbridges. In order to measure the gain bandwidth, we used two identical BWOs (140 or 660 GHz), one functioning as a local oscillator and the other as a signal source. The bandwidth we achieved was 3.5-4 GHz at 4.2 K with the optimal LO and DC biases. Time-domain measurements with a resolution below 300 fs were performed using an electro-optic sampling system, in the temperature range between 4.2 K to 9 K at various values of the bias current and optical power. The obtained response time of the NbN hot-electron bolometer to —100fs-wide Ti:sapphire laser pulses was about 27 ps, what corresponds to the 5.9 GHz gain bandwidth. Introduction The bandwidth of hot-electron bolometer (HEB) mixers has reached values which are record for bolometers. The gain bandwidth for phonon-cooled NbN HEB mixers of 4 GHz for 140 GHz and 650 GHz frequencies [1, 2] and the noise bandwidth of 8 GHz for 650 GHz [2] have been demonstrated. For diffusion-cooled Nb HEB mixers, the bandwidth has reached 6 GHz, when measured at 20--40 GHz [3]. However, there is a definite practical interest to even further extend the bandwidth of these devices. The possibilities of the HEB mixer technology in this direction are far from being exhausted. For example, the future of the NbN HEB technology requires that critical temperature Tc > 10 K and critical current density j c > 10 6 Akm at 4.2 K are simultaneously obtained for d < 3 nm-thick films M. The reduction of the optimal power of the local oscillator PLID below 100 nW leads to the decrease of the device length down to L < 0.2 pm, which, in turn, should bring an additional cooling channel for hot electrons—diffusion into metal contacts and a further bandwidth extension.
We report a record double sideband noise temperature of 600 K (5hν/kB) offered by a NbN hot-electron bolometer receiver at 2.5 THz. Allowing for standing wave effects, this value was found to be constant in the intermediate frequency range 1–7 GHz, which indicates that the mixer has an unprecedentedly large noise bandwidth in excess of 7 GHz. The insight into this is provided by gain bandwidth measurements performed at the superconducting transition. They show that the dependence of the bandwidth on the mixer length follows the model for an HEB mixer with diffusion and phonon cooling of the hot electrons.