Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

APS

Apparatus for fermion atomic clock, atom interferometry and quantum pumping experiments

Megan Ivory, Austin R. Ziltz, J. P. Field, S. Aubin

Published Mar 1, 2010• 0 citations
OpenAlex

Related papers

Atomic Clocks and Atom Interferometry

Christian Bordé

Springer eBooks•Jan 1, 2002•5 citations

Apparatus for Ultra-Cold Fermion Interferometry

S. Aubin, A. Teijeiro Garcia, B. J. DeSalvo

Bulletin of the American Physical Society•May 29, 2008•0 citations

Multiphoton clock atom interferometry

Jan Rudolph, Samuel P. Carman, Benjamin E. Garber +7 more

Optical and Quantum Sensing and Precision Metrology II•Mar 19, 2025•0 citations

Atom chip apparatus for experiments with ultracold rubidium and potassium gases

Megan Ivory, Austin R. Ziltz, Charles Fancher +7 more

We present a dual chamber atom chip apparatus for generating ultracold (87)Rb and (39)K atomic gases. The apparatus produces quasi-pure Bose-Einstein condensates of 10(4) (87)Rb atoms in an atom chip trap that features a dimple and good optical access. We have also demonstrated production of ultracold (39)K and subsequent loading into the chip trap. We describe the details of the dual chamber vacuum system, the cooling lasers, the magnetic trap, the multicoil magnetic transport system, the atom chip, and two optical dipole traps. Due in part to the use of light-induced atom desorption, the laser cooling chamber features a sufficiently good vacuum to also support optical dipole trap-based experiments. The apparatus is well suited for studies of atom-surface forces, quantum pumping and transport experiments, atom interferometry, novel chip-based traps, and studies of one-dimensional many-body systems.

Review of Scientific Instruments•Apr 1, 2014•12 citations

Precision time and frequency techniques for atomic clock and quantum networks

Tara M. Fortier

URSI Atlantic Radio Science Conference•Jan 1, 2024•0 citations

Sr atom interferometry with the optical clock transition as a gravimeter and a gravity gradiometer

Liang Hu, Enlong Wang, Leonardo Salvi +3 more

Abstract We characterize the performance of a gravimeter and a gravity gradiometer based on the 1S0–3P0 clock transition of strontium atoms. We use this new quantum sensor to measure the gravitational acceleration with a relative sensitivity of after 150 s of integration time, representing the first realisation of an atomic interferometry gravimeter based on a single-photon transition. Various noise contributions to the gravimeter are measured and characterized, with the current primary limitation to sensitivity seen to be the intrinsic noise of the interferometry laser itself. In a gravity gradiometer configuration, a differential phase sensitivity of 1.53 rad was achieved at an artificially introduced differential phase of rad. We experimentally investigated the effects of the contrast and visibility based on various parameters and achieved a total interferometry time of 30 ms, which is longer than previously reported for such interferometers. The characterization and determined limitations of the present apparatus employing 88Sr atoms provides a guidance for the future development of large-scale clock-transition gravimeters and gravity gradiometers with alkali-earth and alkali-earth-like atoms (e.g. 87Sr, Ca, Yb, Cd).

arXiv:1907.10537•Classical and Quantum Gravity•Oct 11, 2019•61 citations
We present a dual chamber atom chip apparatus for generating ultracold (87)Rb and (39)K atomic gases. The apparatus produces quasi-pure Bose-Einstein condensates of 10(4) (87)Rb atoms in an atom chip trap that features a dimple and good optical access. We have also demonstrated production of ultracold (39)K and subsequent loading into the chip trap. We describe the details of the dual chamber vacuum system, the cooling lasers, the magnetic trap, the multicoil magnetic transport system, the atom chip, and two optical dipole traps. Due in part to the use of light-induced atom desorption, the laser cooling chamber features a sufficiently good vacuum to also support optical dipole trap-based experiments. The apparatus is well suited for studies of atom-surface forces, quantum pumping and transport experiments, atom interferometry, novel chip-based traps, and studies of one-dimensional many-body systems.
Abstract We characterize the performance of a gravimeter and a gravity gradiometer based on the 1S0–3P0 clock transition of strontium atoms. We use this new quantum sensor to measure the gravitational acceleration with a relative sensitivity of after 150 s of integration time, representing the first realisation of an atomic interferometry gravimeter based on a single-photon transition. Various noise contributions to the gravimeter are measured and characterized, with the current primary limitation to sensitivity seen to be the intrinsic noise of the interferometry laser itself. In a gravity gradiometer configuration, a differential phase sensitivity of 1.53 rad was achieved at an artificially introduced differential phase of rad. We experimentally investigated the effects of the contrast and visibility based on various parameters and achieved a total interferometry time of 30 ms, which is longer than previously reported for such interferometers. The characterization and determined limitations of the present apparatus employing 88Sr atoms provides a guidance for the future development of large-scale clock-transition gravimeters and gravity gradiometers with alkali-earth and alkali-earth-like atoms (e.g. 87Sr, Ca, Yb, Cd).