Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1907.10537 · Classical and Quantum Gravity

Sr atom interferometry with the optical clock transition as a gravimeter and a gravity gradiometer

Liang Hu, Enlong Wang, Leonardo Salvi, Jonathan N. Tinsley, Guglielmo Maria Tino, N. Poli

Published Oct 11, 2019• 61 citations
arXivHTMLPDF

Abstract

Abstract We characterize the performance of a gravimeter and a gravity gradiometer based on the 1S0–3P0 clock transition of strontium atoms. We use this new quantum sensor to measure the gravitational acceleration with a relative sensitivity of after 150 s of integration time, representing the first realisation of an atomic interferometry gravimeter based on a single-photon transition. Various noise contributions to the gravimeter are measured and characterized, with the current primary limitation to sensitivity seen to be the intrinsic noise of the interferometry laser itself. In a gravity gradiometer configuration, a differential phase sensitivity of 1.53 rad was achieved at an artificially introduced differential phase of rad. We experimentally investigated the effects of the contrast and visibility based on various parameters and achieved a total interferometry time of 30 ms, which is longer than previously reported for such interferometers. The characterization and determined limitations of the present apparatus employing 88Sr atoms provides a guidance for the future development of large-scale clock-transition gravimeters and gravity gradiometers with alkali-earth and alkali-earth-like atoms (e.g. 87Sr, Ca, Yb, Cd).

DOI
10.1088/1361-6382/ab4d18

Related papers

Atom Interferometry with the Sr Optical Clock Transition

Liang Hu, N. Poli, Leonardo Salvi +1 more

We report on the realization of a matter-wave interferometer based on single-photon interaction on the ultranarrow optical clock transition of strontium atoms. We experimentally demonstrate its operation as a gravimeter and as a gravity gradiometer. No reduction of interferometric contrast was observed for a total interferometer time up to ∼10 ms, limited by geometric constraints of the apparatus. Single-photon interferometers represent a new class of high-precision sensors that could be used for the detection of gravitational waves in so far unexplored frequency ranges and to enlighten the boundary between quantum mechanics and general relativity.

arXiv:1708.05116•Physical Review Letters•Dec 27, 2017•149 citations

Characterization of the gravity gradiometer based on the Sr optical clock transition

Liang Hu, Leonardo Salvi, Enlong Wang +2 more

We present a gravity gradiometer with the strontium optical clock transition by integrating a double lattice launch technique to develop two atomic samples vertically and a new method to add an artificial phase shift between two samples. We experimentally characterize the launch performance and the robustness of adding the artificial phase shift. The tunable differential phase shift is particularly important for characterizing the performance of a gravity gradiometer when the separation of the two clouds is limited by the geometrical constraints. Moreover, numerical simulation results indicate that the systematic error of the differential phase measurement can be largely reduced when the ellipse phase approaches ±π/2 rad by simply tuning the relative phase between two RF signals.

European Frequency and Time Forum•Apr 1, 2018•0 citations

Bragg gravity-gradiometer using the1S0–3P1intercombination transition of88Sr

R P del Aguila, Tommaso Mazzoni, L Hu +3 more

We present a gradiometer based on matter-wave interference of alkaline-earth-metal atoms, namely 88 Sr. The coherent manipulation of the atomic external degrees of freedom is obtained by large-momentum-transfer Bragg diffraction, driven by laser fields detuned away from the narrow 1 S 0 – 3 P 1 intercombination transition. We use a well-controlled artificial gradient, realized by changing the relative frequencies of the Bragg pulses during the interferometer sequence, in order to characterize the sensitivity of the gradiometer. The sensitivity reaches 1.5 × 10 −5 s −2 for an interferometer time of 20 ms, limited only by geometrical constraints. We observed extremely low sensitivity of the gradiometric phase to magnetic field gradients, approaching a value 10 4 times lower than the sensitivity of alkali-atom based gradiometers, limited by the interferometer sensitivity. An efficient double-launch technique employing accelerated red vertical lattices from a single magneto-optical trap cloud is also demonstrated. These results highlight strontium as an ideal candidate for precision measurements of gravity gradients, with potential application in future precision tests of fundamental physics.

arXiv:1712.01388•New Journal of Physics•Feb 20, 2018•30 citations

A prototype differential atom interferometer for fundamental physics

Charles F. A. Baynham, Richard Hobson, O. L. Buchmueller +97 more

Abstract Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION 1 , MAGIS 2 , AICE 3 and AEDGE 4 that aim to detect at frequencies at which ground-based 5 and space-borne 6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87 Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit 7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter 8,9 .

arXiv:2504.09158•Nature•Jun 17, 2026•3 citations

Atom Interferometry with the Rb Blue Transitions

Leonardo Salvi, Guglielmo Maria Tino, L. Cacciapuoti +1 more

We demonstrate a novel scheme for Raman-pulse and Bragg-pulse atom interferometry based on the $5\mathrm{S} - 6\mathrm{P}$ blue transitions of $^{87}$Rb that provides an increase by a factor $\sim 2$ of the interferometer phase due to accelerations with respect to the commonly used infrared transition at 780 nm. A narrow-linewidth laser system generating more than 1 W of light in the 420-422 nm range was developed for this purpose. Used as a cold-atom gravity gradiometer, our Raman interferometer attains a stability to differential acceleration measurements of $1\times10^{-8}$ $g$ at 1 s and $2\times 10^{-10}$ $g$ after 2000 s of integration time. When operated on first-order Bragg transitions, the interferometer shows a stability of $6\times10^{-8}$ g at 1 s, averaging to $1\times10^{-9}$ g after 2000 s of integration time. The instrument sensitivity, currently limited by the noise due to spontaneous emission, can be further improved by increasing the laser power and the detuning from the atomic resonance. The present scheme is attractive for high-precision experiments as, in particular, for the determination of the Newtonian gravitational constant.

arXiv:2212.12248•Dec 23, 2022•0 citations

A prototype differential atom interferometer for fundamental physics.

C. Baynham, Richard Hobson, O. L. Buchmueller +90 more

Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION1, MAGIS2, AICE3 and AEDGE4 that aim to detect at frequencies at which ground-based5 and space-borne6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter8,9.

•Apr 10, 2025•0 citations
Abstract We characterize the performance of a gravimeter and a gravity gradiometer based on the 1S0–3P0 clock transition of strontium atoms. We use this new quantum sensor to measure the gravitational acceleration with a relative sensitivity of after 150 s of integration time, representing the first realisation of an atomic interferometry gravimeter based on a single-photon transition. Various noise contributions to the gravimeter are measured and characterized, with the current primary limitation to sensitivity seen to be the intrinsic noise of the interferometry laser itself. In a gravity gradiometer configuration, a differential phase sensitivity of 1.53 rad was achieved at an artificially introduced differential phase of rad. We experimentally investigated the effects of the contrast and visibility based on various parameters and achieved a total interferometry time of 30 ms, which is longer than previously reported for such interferometers. The characterization and determined limitations of the present apparatus employing 88Sr atoms provides a guidance for the future development of large-scale clock-transition gravimeters and gravity gradiometers with alkali-earth and alkali-earth-like atoms (e.g. 87Sr, Ca, Yb, Cd).
We report on the realization of a matter-wave interferometer based on single-photon interaction on the ultranarrow optical clock transition of strontium atoms. We experimentally demonstrate its operation as a gravimeter and as a gravity gradiometer. No reduction of interferometric contrast was observed for a total interferometer time up to ∼10 ms, limited by geometric constraints of the apparatus. Single-photon interferometers represent a new class of high-precision sensors that could be used for the detection of gravitational waves in so far unexplored frequency ranges and to enlighten the boundary between quantum mechanics and general relativity.
We present a gravity gradiometer with the strontium optical clock transition by integrating a double lattice launch technique to develop two atomic samples vertically and a new method to add an artificial phase shift between two samples. We experimentally characterize the launch performance and the robustness of adding the artificial phase shift. The tunable differential phase shift is particularly important for characterizing the performance of a gravity gradiometer when the separation of the two clouds is limited by the geometrical constraints. Moreover, numerical simulation results indicate that the systematic error of the differential phase measurement can be largely reduced when the ellipse phase approaches ±π/2 rad by simply tuning the relative phase between two RF signals.
We present a gradiometer based on matter-wave interference of alkaline-earth-metal atoms, namely 88 Sr. The coherent manipulation of the atomic external degrees of freedom is obtained by large-momentum-transfer Bragg diffraction, driven by laser fields detuned away from the narrow 1 S 0 – 3 P 1 intercombination transition. We use a well-controlled artificial gradient, realized by changing the relative frequencies of the Bragg pulses during the interferometer sequence, in order to characterize the sensitivity of the gradiometer. The sensitivity reaches 1.5 × 10 −5 s −2 for an interferometer time of 20 ms, limited only by geometrical constraints. We observed extremely low sensitivity of the gradiometric phase to magnetic field gradients, approaching a value 10 4 times lower than the sensitivity of alkali-atom based gradiometers, limited by the interferometer sensitivity. An efficient double-launch technique employing accelerated red vertical lattices from a single magneto-optical trap cloud is also demonstrated. These results highlight strontium as an ideal candidate for precision measurements of gravity gradients, with potential application in future precision tests of fundamental physics.
Abstract Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION 1 , MAGIS 2 , AICE 3 and AEDGE 4 that aim to detect at frequencies at which ground-based 5 and space-borne 6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87 Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit 7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter 8,9 .
We demonstrate a novel scheme for Raman-pulse and Bragg-pulse atom interferometry based on the 5S−6P5\mathrm{S} - 6\mathrm{P}5S−6P blue transitions of 87^{87}87Rb that provides an increase by a factor ∼2\sim 2∼2 of the interferometer phase due to accelerations with respect to the commonly used infrared transition at 780 nm. A narrow-linewidth laser system generating more than 1 W of light in the 420-422 nm range was developed for this purpose. Used as a cold-atom gravity gradiometer, our Raman interferometer attains a stability to differential acceleration measurements of 1×10−81\times10^{-8}1×10−8 ggg at 1 s and 2×10−102\times 10^{-10}2×10−10 ggg after 2000 s of integration time. When operated on first-order Bragg transitions, the interferometer shows a stability of 6×10−86\times10^{-8}6×10−8 g at 1 s, averaging to 1×10−91\times10^{-9}1×10−9 g after 2000 s of integration time. The instrument sensitivity, currently limited by the noise due to spontaneous emission, can be further improved by increasing the laser power and the detuning from the atomic resonance. The present scheme is attractive for high-precision experiments as, in particular, for the determination of the Newtonian gravitational constant.
Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION1, MAGIS2, AICE3 and AEDGE4 that aim to detect at frequencies at which ground-based5 and space-borne6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter8,9.