Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Dynamics of kicked laser cooled rubidium atoms

Brian P. Timmons

Published Jan 1, 2006• 0 citations
OpenAlex

Abstract

Scope and Method of Study: The purpose of this research was to use laser cooling techniques to cool a sample of rubidium 87 atoms and pulse the cold atoms with an off-resonant standing wave of light. Among the objectives of the study was to understand the parameters needed to place the cold atoms in a quantum accelerator mode and to compare with experiments performed with cesium 133 atoms. A vacuum system and optical system were designed and built to produce a sample of laser cooled rubidium 87 atoms.

Related papers

Interaction of Intense laser Pulses with Ultra-cold Atoms

D. Ciampini, F. Fuso, Jörg Helge Müller +3 more

The recent development of laser cooling and trapping techniques has made possible the controlled realization of dense and cold atomic samples, thus opening the way for spectroscopic investigations in the low and ultra-low temperature regimes not accessible with conventional techniques. In our lab, an apparatus for laser cooling and Bose-Einstein condensation of rubidium atoms is in operation, producing a sample large enough to perform reliable investigations by absorption or emission techniques. Moving from previous photoionization experiments of laser-cooled atoms in a magneto-optical trap irradiated by cw-laser radiation [1] and stimulated by the interest grown recently on ultra-cold plasma [2], we have started a series of experiments aimed at investigating the interaction of intense laser pulses with the ultra-cold neutral sample, boty aboeand below the condensation temperature. Radiation from an excimer-pumped dye laser was used at a wavelength close to 594 nm, corresponding to the ionization threshold of rubidium for two photon non-resonant absorption from the ground state, with intensities in the tens of MW/cm^2 range and a pulse duration of 16 ns. Preliminary results, attained through the dynamical analysis (atom number, temperature) of the cold atom sample after the arrival of the laser pulse, suggest the occurrence of different processes, initiated by multi-photon ionization, involving collisions between cold electrons and ultra-cold neutrals, recombination at low temperatures and collective processes in the weak and cold plasma. Interpretation of those results demonstrates that this class of experiments, based on a variety of topics typical of atomic, plasma and statistical physics, can open the way for novel and intriguing investigations of laser-matter interaction. Further experimental developments will include duplication of the laser pulse frequency and one photon ionization of ground state rubidium laser-cooled atoms. [1] O. Maragò et al., Phys. Rev. A 57 R4110 (1998); E., Arimondo et al., Appl. Surf. Sci. 154-155 527 (2000); F. Fuso et al., Opt. Commun. 173 223 (2000). [2] T.C. Killian et al., Phys. Rev. Lett. 83 4776 (1999); S. Kulin et al., Phys. Rev. Lett. 85 318 (2000).

•May 1, 2001•0 citations

Precision control of magneto-optically cooled rubidium atoms (Invited Paper)

Síle Nic Chormaic, Alexander Yarovitski, Brian Shortt +2 more

Research interest in designing sources of cold atoms has significantly increased during the past ten years with the development of suitable laser sources for magneto-optical trapping and the further mastering of evaporative cooling in order to achieve Bose-Einstein condensation. The magneto-optical trap is now viewed as a standard research facility worldwide and has opened up many new exciting research directions in atomic physics. One area of interest is that of combining spherical microcavities with cold atomic sources in order to achieve efficient photon exchange between the cavity and atom for further understandings of cavity quantum electrodynamics. This could eventually lead to atom entanglement via photon exchange which would have implications for quantum logic design. However, initial attempts to achieve such interactions have been hindered by inadequate control and manipulation of the cold atom source. Here, we present work on designing and building an ultra-stable source of magneto-optically cooled rubidium atoms with a temperature in the tens of microKelvin range. We discuss the different cooling mechanisms involved in the process and present a suitable experimental arrangement including details on the ultra-high vacuum chamber, the laser systems being used and the source of rubidium vapour. Finally, we discuss some future direction for the research including the diffraction of atoms from gratings and micron-sized objects and the parameter control of the cloud of atoms.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jun 3, 2005•2 citations

Laser Cooling of Neutral Atoms

Strick, Jeffrey E

The theory of cooling neutral atoms to microkelvin temperatures using a magneto optical trap will be presented. The system that is discussed uses a stabilized grating tuned diode laser that is controlled using feedback from a saturation absorption spectrophotometer to produce narrow band continuously tunable IR light for trapping rubidium atoms. A description of the design and construction of each of the components used to create the magneto optical trap will also be discussed. In the final section a description of an exceptionally accurate atomic clock that is used to measure the natural resonance frequency of laser cooled cesium atoms is also presented.

•Jan 1, 2002•0 citations

Cooling of rubidium atoms in pulsed diffuse laser light

Hua-Dong Cheng, Xucheng Wang, Ling Xiao +3 more

This paper reports an experiment on laser cooling of 87 Rb atoms in pulsed diffuse light, which is the key step towards a compact cold atom clock. It deduces an empirical formula to simulate the pulse cooling process based on the loading of cold atoms in cooling time and the loss in the dead time, which is in agreement with the experimental data. The formula gives a reference to select the parameters for the cold atom clock.

Chinese Physics B•Feb 1, 2011•8 citations

Quantum accelerator modes: A tool for atom optics

R. M. Godun, M. B. d’Arcy, Markus K Oberthaler +2 more

We describe an atom-optical technique for producing large changes in the momentum of cold atoms using a pulsed standing wave of off-resonant light. Experimental results are presented showing how the efficiency and the amount of momentum transfer depend on the parameters of the light field. We also present a theoretical analysis and derive a closed formula which is in excellent agreement with the experimental data.

Physical Review A•Jun 14, 2000•53 citations

Laboratory Apparatus Generates Dual-Species Cold Atomic Beam

Robert J. Thompson, William M. Klipstein, James M. Kohel +6 more

A laser cooling apparatus that generates a cold beam of rubidium and cesium atoms at low pressure has been constructed as one of several intermediate products of a continuing program of research on laser cooling and atomic physics. Laser-cooled atomic beams, which can have temperatures as low as a microkelvin, have been used in diverse applications that include measurements of fundamental constants, atomic clocks that realize the international standard unit of time, atom-wave interferometers, and experiments on Bose-Einstein condensation. The present apparatus is a prototype of one being evaluated for use in a proposed microgravitational experiment called the Quantum Interferometric Test of Equivalence (QuITE). In this experiment, interferometric measurements of cesium and rubidium atoms in free fall would be part of a test of Einstein s equivalence principle. The present apparatus and its anticipated successors may also be useful in other experiments, in both microgravity and normal Earth gravity, in which there are requirements for dual-species atomic beams, low temperatures, and low pressures. The apparatus includes a pyramidal magneto-optical trap in which the illumination is provided by multiple lasers tuned to frequencies characteristic of the two atomic species. The inlet to the apparatus is located in a vacuum chamber that contains rubidium and cesium atoms at a low pressure; the beam leaving through the outlet of the apparatus is used to transfer the atoms to a higher-vacuum (lower-pressure) chamber in which measurements are performed. The pyramidal magneto-optical trap is designed so that the laser cooling forces in one direction are unbalanced, resulting in a continuous cold beam of atoms that leak out of the trap (see figure). The radiant intensity (number of atoms per unit time per unit solid angle) of the apparatus is the greatest of any other source of the same type reported to date. In addition, this is the first such apparatus capable of producing a slow, collimated beam that contains two atomic species at the same time.

•Jul 1, 2004•0 citations
Scope and Method of Study: The purpose of this research was to use laser cooling techniques to cool a sample of rubidium 87 atoms and pulse the cold atoms with an off-resonant standing wave of light. Among the objectives of the study was to understand the parameters needed to place the cold atoms in a quantum accelerator mode and to compare with experiments performed with cesium 133 atoms. A vacuum system and optical system were designed and built to produce a sample of laser cooled rubidium 87 atoms.
The recent development of laser cooling and trapping techniques has made possible the controlled realization of dense and cold atomic samples, thus opening the way for spectroscopic investigations in the low and ultra-low temperature regimes not accessible with conventional techniques. In our lab, an apparatus for laser cooling and Bose-Einstein condensation of rubidium atoms is in operation, producing a sample large enough to perform reliable investigations by absorption or emission techniques. Moving from previous photoionization experiments of laser-cooled atoms in a magneto-optical trap irradiated by cw-laser radiation [1] and stimulated by the interest grown recently on ultra-cold plasma [2], we have started a series of experiments aimed at investigating the interaction of intense laser pulses with the ultra-cold neutral sample, boty aboeand below the condensation temperature. Radiation from an excimer-pumped dye laser was used at a wavelength close to 594 nm, corresponding to the ionization threshold of rubidium for two photon non-resonant absorption from the ground state, with intensities in the tens of MW/cm^2 range and a pulse duration of 16 ns. Preliminary results, attained through the dynamical analysis (atom number, temperature) of the cold atom sample after the arrival of the laser pulse, suggest the occurrence of different processes, initiated by multi-photon ionization, involving collisions between cold electrons and ultra-cold neutrals, recombination at low temperatures and collective processes in the weak and cold plasma. Interpretation of those results demonstrates that this class of experiments, based on a variety of topics typical of atomic, plasma and statistical physics, can open the way for novel and intriguing investigations of laser-matter interaction. Further experimental developments will include duplication of the laser pulse frequency and one photon ionization of ground state rubidium laser-cooled atoms. [1] O. Maragò et al., Phys. Rev. A 57 R4110 (1998); E., Arimondo et al., Appl. Surf. Sci. 154-155 527 (2000); F. Fuso et al., Opt. Commun. 173 223 (2000). [2] T.C. Killian et al., Phys. Rev. Lett. 83 4776 (1999); S. Kulin et al., Phys. Rev. Lett. 85 318 (2000).
Research interest in designing sources of cold atoms has significantly increased during the past ten years with the development of suitable laser sources for magneto-optical trapping and the further mastering of evaporative cooling in order to achieve Bose-Einstein condensation. The magneto-optical trap is now viewed as a standard research facility worldwide and has opened up many new exciting research directions in atomic physics. One area of interest is that of combining spherical microcavities with cold atomic sources in order to achieve efficient photon exchange between the cavity and atom for further understandings of cavity quantum electrodynamics. This could eventually lead to atom entanglement via photon exchange which would have implications for quantum logic design. However, initial attempts to achieve such interactions have been hindered by inadequate control and manipulation of the cold atom source. Here, we present work on designing and building an ultra-stable source of magneto-optically cooled rubidium atoms with a temperature in the tens of microKelvin range. We discuss the different cooling mechanisms involved in the process and present a suitable experimental arrangement including details on the ultra-high vacuum chamber, the laser systems being used and the source of rubidium vapour. Finally, we discuss some future direction for the research including the diffraction of atoms from gratings and micron-sized objects and the parameter control of the cloud of atoms.
The theory of cooling neutral atoms to microkelvin temperatures using a magneto optical trap will be presented. The system that is discussed uses a stabilized grating tuned diode laser that is controlled using feedback from a saturation absorption spectrophotometer to produce narrow band continuously tunable IR light for trapping rubidium atoms. A description of the design and construction of each of the components used to create the magneto optical trap will also be discussed. In the final section a description of an exceptionally accurate atomic clock that is used to measure the natural resonance frequency of laser cooled cesium atoms is also presented.
A laser cooling apparatus that generates a cold beam of rubidium and cesium atoms at low pressure has been constructed as one of several intermediate products of a continuing program of research on laser cooling and atomic physics. Laser-cooled atomic beams, which can have temperatures as low as a microkelvin, have been used in diverse applications that include measurements of fundamental constants, atomic clocks that realize the international standard unit of time, atom-wave interferometers, and experiments on Bose-Einstein condensation. The present apparatus is a prototype of one being evaluated for use in a proposed microgravitational experiment called the Quantum Interferometric Test of Equivalence (QuITE). In this experiment, interferometric measurements of cesium and rubidium atoms in free fall would be part of a test of Einstein s equivalence principle. The present apparatus and its anticipated successors may also be useful in other experiments, in both microgravity and normal Earth gravity, in which there are requirements for dual-species atomic beams, low temperatures, and low pressures. The apparatus includes a pyramidal magneto-optical trap in which the illumination is provided by multiple lasers tuned to frequencies characteristic of the two atomic species. The inlet to the apparatus is located in a vacuum chamber that contains rubidium and cesium atoms at a low pressure; the beam leaving through the outlet of the apparatus is used to transfer the atoms to a higher-vacuum (lower-pressure) chamber in which measurements are performed. The pyramidal magneto-optical trap is designed so that the laser cooling forces in one direction are unbalanced, resulting in a continuous cold beam of atoms that leak out of the trap (see figure). The radiant intensity (number of atoms per unit time per unit solid angle) of the apparatus is the greatest of any other source of the same type reported to date. In addition, this is the first such apparatus capable of producing a slow, collimated beam that contains two atomic species at the same time.