Inertial sensors based on matter-wave interferometry are currently approaching the precision and accuracy of state-of-the-art classical sensors. While these devices are often realised with ultracold but not Bose-condensed atoms as matter waves, employing Bose-Einstein Condensates (BEC) promises to overcome certain limitations, especially those related to the ensemble's expansion. The point-source like character of BECs also enables utilising spatial interference patterns to measure e.g. rotation rates in single-shot experiments. Matter wave-based inertial sensors are considered for experiments ranging from Gravitational Wave detection to tests of the Universality of Free Fall (UFF) to gain insight into the joint between Quantum Mechanics and General Relativity. In the scope of this thesis, matter-wave interferometry with BECs was demonstrated for the first time in a microgravity environment with the QUANTUS-1 apparatus. The same instrument was then employed as a quantum tiltmeter utilising a novel beam-splitting mechanism known as Bragg Double Diffraction. To this end, the QUANTUS-1 apparatus designed as a BEC instrument to be operated in the drop tower at ZARM at University of Bremen was equipped with optics and laser systems required for performing matter-wave interferometry based on Bragg Diffraction. The apparatus employs an atom chip to create BECs of around 10000 Rubidium 87 atoms within 15 s. With a Mach-Zehnder like interferometer scheme, spatial interference fringes were observed after a free evolution time in the interferometer of up to 677 ms. To achieve these long time scales, a method known as Delta-Kick Collimation (DKC) was adapted to slow the expansion of the BEC to a kinetic energy equivalent below 1 nK, and the atoms were transferred to a non-magnetic Zeeman state via an adiabatic rapid passage (ARP). A similar interferometer scheme with a newly developed beam-splitter mechanism known as Bragg Double Diffraction was used to measure the tilt of the instrument on ground with a precision of up to 4.4 AA rad. This thesis presents an overview of the apparatus including ground-based characterisations of all required experimental steps. Results from over 400 free fall experiments are evaluated for expansion studies of the BEC and matter-wave interferometry in microgravity. The time-evolution of first and second order Bragg Double Diffraction beam splitters is studied, and an interferometer sensitive to the tilt of the instrument is implemented. Based on this work, a gravimeter with a new launch mechanism comprising Bragg beam splitters and Bloch oscillations to enable atomic fountains in atom-chip based devices was developed. The microgravity experiments were adapted for the MAIUS-1 sounding-rocket instrument to create the first man-made BEC in outer space and study the feasibility of operating matter-wave interferometers on space-borne platforms. The results of this thesis lay the groundwork for future space-borne missions using matter-wave interferometry for precision measurements of inertial forces.
Ultracold atomic gases hold unique promise for space science by capitalizing on quantum advantages and extended freefall, afforded in a microgravity environment, to enable next-generation precision sensors. Atom interferometers are a class of quantum sensors which can use freely falling gases of atoms cooled to sub-photon-recoil temperatures to provide unprecedented sensitivities to accelerations, rotations, and gravitational forces, and are currently being developed for space-based applications in gravitational, earth, and planetary sciences, as well as to search for subtle forces that could signify physics beyond General Relativity and the Standard Model. NASA's Cold Atom Lab (CAL) operates onboard the International Space Station as a multi-user facility for studies of ultracold atoms and to mature quantum technologies, including atom interferometry, in persistent microgravity. In this paper, we report on path-finding experiments utilizing ultracold
87Rb atoms in the CAL atom interferometer, which was enabled by an on-orbit upgrade of the CAL science module: A three-pulse Mach-Zehnder interferometer was studied to understand limitations from the influence of ISS vibrations. Additionally, Ramsey shear-wave interferometry was used to manifest interference patterns in a single run that were observable for over 150 ms free-expansion time. Finally, the CAL atom interferometer was used to remotely measure the photon recoil from the atom interferometer laser as a demonstration of the first quantum sensor using matter-wave interferometry in space.
Matter-wave interferometry with cold atoms offers a competitive tool for absolute measurements of acceleration and rotation. The sensitivity of atom-interferometric gyroscopes depends on the area enclosed by the interferometer. In this contribution, we present a concept for a rotation sensor, utilizing a multi-loop interferometer geometry to achieve a scalable area while maintaining a compact setup. It enables rotation measurements of a single axis on ground and can be extended to measure rotations along all three spatial axes in microgravity, for potential applications in space missions, Earth observation, and navigation systems.