Coherent Oscillations on a Single Cooper Pair Box with RF-SET Readout

Justin F. Schneiderman, Alexandre Guillaume, Per Delsing, Hans M. Bozler, P. M. Echternach

Published Mar 1, 2004• 0 citations
OpenAlex

Related papers

Harmonic oscillator driven interference in the single Cooper pair box

David Gunnarsson, Antti Paila, Teijo Lehtinen +1 more

•Jan 1, 2007•0 citations

Quantum coherence in a single-Cooper-pair box: experiments in the frequency and time domains

Yasunobu Nakamura, Yu. A. Pashkin, Jaw-Shen Tsai

Physica B Condensed Matter•May 1, 2000•19 citations

Coherent control of macroscopic quantum states in a single-Cooper-pair box

Y. Nakamura, Yu. A. Pashkin, J. S. Tsai

arXiv:cond-mat/9904003•Nature•Apr 1, 1999•2,385 citations

The Single Cooper Pair Box - a Quantum-Mechanical Electronic Circuit

David Gunnarsson

In this thesis the single Cooper pair box (SCB) is investigated with a radio frequency single electron transistor (RF-SET). The RF-SET is used as an electrometer to detect the charge of the SCB. The SCB can be regarded as a quantum two-level system and could therefore be a possible qubit. Both the SCB and the RF-SET have been fabricated with e-beam lithography followed by two-angle shadow evaporation of aluminium. The system has been measured in a dilution refrigerator at temperatures of ~30 mK. A charge sensitivity of 2.3 μe/square root of Hz was measured for an optimized RF-SET with a bandwidth of 7 MHz, operated in the superconducting state. In a phase sensitive measurement of the RF-SET reflected signal, the gate dependence of the quantum capacitance, due to avoided level crossing, was detected in a superconducting SET. Coulomb staircases for the SCB were obtained by changing the charge of the SCB by ramping a gate voltage and continuously measuring the charge with the RF-SET. To prevent quasiparticle poisoning of the SCB island, we have used a method of graded gaps. Here we exploit the greater reduction of the superconducting gap for the connecting leads with an external magnetic field applied, resulting in a higher gap for the island. This creates an effective barrier against quasiparticle tunnelling. The charging energy and the Josephson coupling energy of the SCB were measured with microwave spectroscopy. The SCBs were fabricated in a SQUID geometry, which made it possible to tune the Josephson coupling energy of the box. This tuning was verified through microwave spectroscopy. The effect of tuning could also be seen in the pure 2e Coulomb staircase, as a predicted smearing of the staircase, which was in excellent agreement with the independent spectroscopy data. Coherent quantum oscillation of the SCB charge state was measured by applying nonadiabatic DC-pulses to the SCB gate. The measured amplitude of the charge oscillations was higher than 70%. The deviation from 100% can be explained by the initial charge state purity and the finite rise time of the pulses. The longest decoherence time of the charge oscillations was T2 = 9 ns at the charge degeneracy point. It was found to be limited by relaxation. Away from the degeneracy point the decoherence time was limited by pure dephasing, due to low frequency charge fluctuators.

•Jan 1, 2005•0 citations

Characterization of a single Cooper pair box

David Gunnarsson, T. Duty, Kevin Bladh +2 more

Physica E Low-dimensional Systems and Nanostructures•Feb 28, 2003•1 citation

Towards Single Shot Measurements of a Cooper Pair Box Qubit Using an RF Single Electron Transistor

Carlos Alberto Sánchez

I report an investigation into using an rf Single Electron Transistor (rf-SET) to implement single shot readout of the quantum state of a Cooper pair box. I fabricated Al/AlOx/Al SETs and Cooper pair boxes using e-beam lithography and double-angle evaporation. The devices had typical charging energies of about 1 K and were measured at 30 mK in a dilution refrigerator. I built rf-SETs with an LC resonant circuit integrated on the chip and operating frequencies of 650 MHz and 1.5 GHz. The rf-SETs had a typical bandwidth of 30 MHz and the best achieved charge sensitivity was 8X10-6 erms/(Hz)1/2 at 1.5 GHz. The rf-SETs were used to measure the Coulomb staircase on the Cooper pair box. Measurements of the staircase show features due to quasiparticle poisoning that are dependent on temperature and SET bias. The data was compared to a theory I developed to extend existing theories of quasiparticle poisoning. My model is based on the calculation of tunneling rates to explain observations of parity effects in the Cooper pair box over a wide temperature range. Quantum state control of the Cooper pair box was demonstrated by using fast voltage pulses applied to the gate. Temporal oscillations of charge states and spectroscopy measurements reveal a dephasing time T2=200 ps at 30 mK, for a drive frequency of 30 GHz. The energy relaxation time T1=140 ns was determined from time domain measurements of the decay of the Cooper pair box charge. The fidelity of single shot measurements and the feasibility of this quantum readout scheme based on the results are discussed.

•Dec 5, 2005•0 citations
In this thesis the single Cooper pair box (SCB) is investigated with a radio frequency single electron transistor (RF-SET). The RF-SET is used as an electrometer to detect the charge of the SCB. The SCB can be regarded as a quantum two-level system and could therefore be a possible qubit. Both the SCB and the RF-SET have been fabricated with e-beam lithography followed by two-angle shadow evaporation of aluminium. The system has been measured in a dilution refrigerator at temperatures of ~30 mK. A charge sensitivity of 2.3 μe/square root of Hz was measured for an optimized RF-SET with a bandwidth of 7 MHz, operated in the superconducting state. In a phase sensitive measurement of the RF-SET reflected signal, the gate dependence of the quantum capacitance, due to avoided level crossing, was detected in a superconducting SET. Coulomb staircases for the SCB were obtained by changing the charge of the SCB by ramping a gate voltage and continuously measuring the charge with the RF-SET. To prevent quasiparticle poisoning of the SCB island, we have used a method of graded gaps. Here we exploit the greater reduction of the superconducting gap for the connecting leads with an external magnetic field applied, resulting in a higher gap for the island. This creates an effective barrier against quasiparticle tunnelling. The charging energy and the Josephson coupling energy of the SCB were measured with microwave spectroscopy. The SCBs were fabricated in a SQUID geometry, which made it possible to tune the Josephson coupling energy of the box. This tuning was verified through microwave spectroscopy. The effect of tuning could also be seen in the pure 2e Coulomb staircase, as a predicted smearing of the staircase, which was in excellent agreement with the independent spectroscopy data. Coherent quantum oscillation of the SCB charge state was measured by applying nonadiabatic DC-pulses to the SCB gate. The measured amplitude of the charge oscillations was higher than 70%. The deviation from 100% can be explained by the initial charge state purity and the finite rise time of the pulses. The longest decoherence time of the charge oscillations was T2 = 9 ns at the charge degeneracy point. It was found to be limited by relaxation. Away from the degeneracy point the decoherence time was limited by pure dephasing, due to low frequency charge fluctuators.
I report an investigation into using an rf Single Electron Transistor (rf-SET) to implement single shot readout of the quantum state of a Cooper pair box. I fabricated Al/AlOx/Al SETs and Cooper pair boxes using e-beam lithography and double-angle evaporation. The devices had typical charging energies of about 1 K and were measured at 30 mK in a dilution refrigerator. I built rf-SETs with an LC resonant circuit integrated on the chip and operating frequencies of 650 MHz and 1.5 GHz. The rf-SETs had a typical bandwidth of 30 MHz and the best achieved charge sensitivity was 8X10-6 erms/(Hz)1/2 at 1.5 GHz. The rf-SETs were used to measure the Coulomb staircase on the Cooper pair box. Measurements of the staircase show features due to quasiparticle poisoning that are dependent on temperature and SET bias. The data was compared to a theory I developed to extend existing theories of quasiparticle poisoning. My model is based on the calculation of tunneling rates to explain observations of parity effects in the Cooper pair box over a wide temperature range. Quantum state control of the Cooper pair box was demonstrated by using fast voltage pulses applied to the gate. Temporal oscillations of charge states and spectroscopy measurements reveal a dephasing time T2=200 ps at 30 mK, for a drive frequency of 30 GHz. The energy relaxation time T1=140 ns was determined from time domain measurements of the decay of the Cooper pair box charge. The fidelity of single shot measurements and the feasibility of this quantum readout scheme based on the results are discussed.