Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physica B Condensed Matter

Quantum coherence in a single-Cooper-pair box: experiments in the frequency and time domains

Yasunobu Nakamura, Yu. A. Pashkin, Jaw-Shen Tsai

Published May 1, 2000• 19 citations
Publisher
DOI
10.1016/s0921-4526(99)01790-1

Related papers

Coherent control of macroscopic quantum states in a single-Cooper-pair box

Y. Nakamura, Yu. A. Pashkin, J. S. Tsai

arXiv:cond-mat/9904003•Nature•Apr 1, 1999•2,385 citations

Coherent Oscillations on a Single Cooper Pair Box with RF-SET Readout

Justin F. Schneiderman, Alexandre Guillaume, Per Delsing +2 more

APS•Mar 1, 2004•0 citations

Quantum Coherence in the Single Cooper Pair Box

Kevin Bladh

This thesis presents measurements of quantum coherence in a single Cooper pair box, where quantum oscillations of charge between a reservoir and a small superconducting island have been observed. The single Cooper pair box (SCB) consists of a small metallic island which is connected to a reservoir via a tunnel junction. In the superconducting state, Cooper pairs are free to tunnel to and from the island, whose potential can be controlled by a gate voltage. A graded gap method was used to prevent quasiparticles from tunneling onto the island. For this purpose, a magnetic field suppressed the superconducting gap in the SCB leads more than in the island. This created an additional energy barrier for quasiparticles to tunnel to the island, making the gate voltage modulation periodic in Cooper pair charge. For a limited range of gate voltage, the SCB was found to behave as a model two-level quantum mechanical system. A non-adiabatic change in the induced island charge was used to bring two charge states into resonance. The resulting time evolution showed clear charge oscillations between the ground and excited state, with a frequency given by the energy level separation divided by Planck's constant. These oscillations had a longest coherence time of T2=9 ns at a point where the pure charge states are degenerate. The coherence time at this point was found to be limited by the relaxation rate, ?1. Away from this point, the coherence time was limited by the dephasing rate, ??. Away from the charge degeneracy, the dependence of T2 on gate charge suggested that low frequency fluctuators were the main source of dephasing. The charge of the Cooper pair box was measured by coupling the SCB capacitively to a radio frequency single electron transistor (RF-SET). The RF-SET was used as an electrometer by measuring the amount of reflection from a resonant microwave circuit in which a single electron transistor (SET) was embedded. A best charge sensitivity of 2.3·10-6 e/sqrt(Hz) and a 7 MHz bandwidth was reached in an improved setup. Another part of this thesis concerns an investigation of electrical filters for use in single electronics experiments. The characteristics of seven different types of cryogenic filters were evaluated.

•Jan 1, 2005•3 citations

Time-domain observation of macroscopic quantum coherence

Vladimir Manucharyan, Jens Koch, L. I. Glazman +1 more

Bulletin of the American Physical Society•Mar 19, 2010•0 citations

Towards Single Shot Measurements of a Cooper Pair Box Qubit Using an RF Single Electron Transistor

Carlos Alberto Sánchez

I report an investigation into using an rf Single Electron Transistor (rf-SET) to implement single shot readout of the quantum state of a Cooper pair box. I fabricated Al/AlOx/Al SETs and Cooper pair boxes using e-beam lithography and double-angle evaporation. The devices had typical charging energies of about 1 K and were measured at 30 mK in a dilution refrigerator. I built rf-SETs with an LC resonant circuit integrated on the chip and operating frequencies of 650 MHz and 1.5 GHz. The rf-SETs had a typical bandwidth of 30 MHz and the best achieved charge sensitivity was 8X10-6 erms/(Hz)1/2 at 1.5 GHz. The rf-SETs were used to measure the Coulomb staircase on the Cooper pair box. Measurements of the staircase show features due to quasiparticle poisoning that are dependent on temperature and SET bias. The data was compared to a theory I developed to extend existing theories of quasiparticle poisoning. My model is based on the calculation of tunneling rates to explain observations of parity effects in the Cooper pair box over a wide temperature range. Quantum state control of the Cooper pair box was demonstrated by using fast voltage pulses applied to the gate. Temporal oscillations of charge states and spectroscopy measurements reveal a dephasing time T2=200 ps at 30 mK, for a drive frequency of 30 GHz. The energy relaxation time T1=140 ns was determined from time domain measurements of the decay of the Cooper pair box charge. The fidelity of single shot measurements and the feasibility of this quantum readout scheme based on the results are discussed.

•Dec 5, 2005•0 citations

The single Cooper-pair box as a charge qubit

Kevin Bladh, T. Duty, David Gunnarsson +1 more

We present a series of measurements on nine single Cooper-pair boxes (SCBs), where the charging energy, E C , and the Josephson coupling energy, E J , have been varied. We have investigated both the ground state properties of the SCBs and their quantum coherent properties. The state of the SCBs could be manipulated by an external gate voltage and the charge was measured by coupling it capacitatively to a radio-frequency single-electron-transistor (RF-SET). By ramping the gate voltage and simultaneously measuring the charge of the SCBs using the RF-SET, we could measure the Coulomb staircases of the SCBs. For sufficiently low E C the SCBs showed a fully 2 e periodic Coulomb staircase. For samples with higher E C the staircase showed a short step for odd number of charges indicating quasi-particle 'poisoning'. However, if E C was not too large, the short step could be removed by applying a parallel magnetic field. We attribute this effect to a stronger suppression of the superconducting energy gap in the reservoir than in the box. Using microwave spectroscopy we have determined E C and E J for the SCBs. These values agree well with the shape of the Coulomb staircases which we measure. For a limited range of gate voltage, the SCBs were found to behave as model two-level quantum-mechanical systems. A non-adiabatic change in the induced island charge was used to bring two charge states into resonance. The resulting time evolution showed clear charge oscillations between the ground and excited state, with an amplitude above 70% and a frequency given by the energy level separation divided by Planck's constant. These oscillations had a longest coherence time of T 2 = 9 ns, at a point where the pure charge states are degenerate. The coherence time at this point was found to be limited by the relaxation rate. Away from the charge degeneracy point, the coherence time was limited by the pure dephasing rate. The dependence of T 2 on gate charge suggested that low frequency fluctuators were the main source of dephasing away from the degeneracy point.

New Journal of Physics•Aug 26, 2005•37 citations
This thesis presents measurements of quantum coherence in a single Cooper pair box, where quantum oscillations of charge between a reservoir and a small superconducting island have been observed. The single Cooper pair box (SCB) consists of a small metallic island which is connected to a reservoir via a tunnel junction. In the superconducting state, Cooper pairs are free to tunnel to and from the island, whose potential can be controlled by a gate voltage. A graded gap method was used to prevent quasiparticles from tunneling onto the island. For this purpose, a magnetic field suppressed the superconducting gap in the SCB leads more than in the island. This created an additional energy barrier for quasiparticles to tunnel to the island, making the gate voltage modulation periodic in Cooper pair charge. For a limited range of gate voltage, the SCB was found to behave as a model two-level quantum mechanical system. A non-adiabatic change in the induced island charge was used to bring two charge states into resonance. The resulting time evolution showed clear charge oscillations between the ground and excited state, with a frequency given by the energy level separation divided by Planck's constant. These oscillations had a longest coherence time of T2=9 ns at a point where the pure charge states are degenerate. The coherence time at this point was found to be limited by the relaxation rate, ?1. Away from this point, the coherence time was limited by the dephasing rate, ??. Away from the charge degeneracy, the dependence of T2 on gate charge suggested that low frequency fluctuators were the main source of dephasing. The charge of the Cooper pair box was measured by coupling the SCB capacitively to a radio frequency single electron transistor (RF-SET). The RF-SET was used as an electrometer by measuring the amount of reflection from a resonant microwave circuit in which a single electron transistor (SET) was embedded. A best charge sensitivity of 2.3·10-6 e/sqrt(Hz) and a 7 MHz bandwidth was reached in an improved setup. Another part of this thesis concerns an investigation of electrical filters for use in single electronics experiments. The characteristics of seven different types of cryogenic filters were evaluated.
I report an investigation into using an rf Single Electron Transistor (rf-SET) to implement single shot readout of the quantum state of a Cooper pair box. I fabricated Al/AlOx/Al SETs and Cooper pair boxes using e-beam lithography and double-angle evaporation. The devices had typical charging energies of about 1 K and were measured at 30 mK in a dilution refrigerator. I built rf-SETs with an LC resonant circuit integrated on the chip and operating frequencies of 650 MHz and 1.5 GHz. The rf-SETs had a typical bandwidth of 30 MHz and the best achieved charge sensitivity was 8X10-6 erms/(Hz)1/2 at 1.5 GHz. The rf-SETs were used to measure the Coulomb staircase on the Cooper pair box. Measurements of the staircase show features due to quasiparticle poisoning that are dependent on temperature and SET bias. The data was compared to a theory I developed to extend existing theories of quasiparticle poisoning. My model is based on the calculation of tunneling rates to explain observations of parity effects in the Cooper pair box over a wide temperature range. Quantum state control of the Cooper pair box was demonstrated by using fast voltage pulses applied to the gate. Temporal oscillations of charge states and spectroscopy measurements reveal a dephasing time T2=200 ps at 30 mK, for a drive frequency of 30 GHz. The energy relaxation time T1=140 ns was determined from time domain measurements of the decay of the Cooper pair box charge. The fidelity of single shot measurements and the feasibility of this quantum readout scheme based on the results are discussed.
We present a series of measurements on nine single Cooper-pair boxes (SCBs), where the charging energy, E C , and the Josephson coupling energy, E J , have been varied. We have investigated both the ground state properties of the SCBs and their quantum coherent properties. The state of the SCBs could be manipulated by an external gate voltage and the charge was measured by coupling it capacitatively to a radio-frequency single-electron-transistor (RF-SET). By ramping the gate voltage and simultaneously measuring the charge of the SCBs using the RF-SET, we could measure the Coulomb staircases of the SCBs. For sufficiently low E C the SCBs showed a fully 2 e periodic Coulomb staircase. For samples with higher E C the staircase showed a short step for odd number of charges indicating quasi-particle 'poisoning'. However, if E C was not too large, the short step could be removed by applying a parallel magnetic field. We attribute this effect to a stronger suppression of the superconducting energy gap in the reservoir than in the box. Using microwave spectroscopy we have determined E C and E J for the SCBs. These values agree well with the shape of the Coulomb staircases which we measure. For a limited range of gate voltage, the SCBs were found to behave as model two-level quantum-mechanical systems. A non-adiabatic change in the induced island charge was used to bring two charge states into resonance. The resulting time evolution showed clear charge oscillations between the ground and excited state, with an amplitude above 70% and a frequency given by the energy level separation divided by Planck's constant. These oscillations had a longest coherence time of T 2 = 9 ns, at a point where the pure charge states are degenerate. The coherence time at this point was found to be limited by the relaxation rate. Away from the charge degeneracy point, the coherence time was limited by the pure dephasing rate. The dependence of T 2 on gate charge suggested that low frequency fluctuators were the main source of dephasing away from the degeneracy point.