Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Force measurement in squeezed dissipative optomechanics in the presence of laser phase noise

Wen-ju Gu, Yueyuan Wang, Zhen Yi, Wen‐Xing Yang, Lihui Sun

Published Apr 6, 2020• 9 citations
Publisher

Abstract

We investigate the force measurement sensitivity in a squeezed dissipative optomechanics within the free-mass regime under the influence of shot noise (SN) from the photon number fluctuations, laser phase noise from the pump laser, thermal noise from the environment, and optical losses from outcoupling and detection inefficiencies. Generally, squeezed light could generate a reduced SN on the squeezed quadrature and an enlarged quantum backaction noise (QBA) due to the antisqueezed conjugate quadrature. With an appropriate choice of phase angle in homodyne detection, QBA is cancellable, leading to an exponentially improved measurement sensitivity for the SN-dominated regime. By now, the effects of laser phase noise that is proportional to laser power emerge. The balance between squeezed SN and phase noise can lead to an sub-SQL sensitivity at an exponentially lower input power. However, the improvement by squeezing is limited by optical losses because high sensitivity is delicate and easily destroyed by optical losses.

DOI
10.1364/oe.389854

Related papers

Homodyne coherent quantum noise cancellation in a hybrid optomechanical force sensor

Hossein Allahverdi, Ali Motazedifard, Ali Dalafi +2 more

In this paper we propose an experimentally viable scheme to enhance the sensitivity of force detection in a hybrid optomechanical setup assisted by squeezed vacuum injection, beyond the standard quantum limit (SQL). The scheme is based on a combination of the coherent quantum noise cancellation (CQNC) strategy with a variational homodyne detection of the cavity output spectrum in which the phase of the local oscillator is optimized. In CQNC, realizing a negative-mass oscillator in the system leads to exact cancellation of the backaction noise from the mechanics due to destructive quantum interference. Squeezed vacuum injection enhances this cancellation and allows sub-SQL sensitivity to be reached in a wide frequency band and at much lower input laser powers. We show here that the adoption of variational homodyne readout enables us to enhance this noise cancellation up to $40\phantom{\rule{3.33333pt}{0ex}}\mathrm{dB}$ compared to the standard case of detection of the optical output phase quadrature, leading to a remarkable force sensitivity of the order of ${10}^{\ensuremath{-}19}\phantom{\rule{0.28em}{0ex}}\mathrm{N}/\sqrt{\mathrm{Hz}}$, about $70%$ enhancement compared to the standard case. Moreover, we show that at nonzero cavity detuning, the signal response can be amplified at a level three to five times larger than that in the standard case without variational homodyne readout, improving the signal-to-noise ratio. Finally, the variational readout CQNC developed in this paper may be applied to other optomechanical-like platforms such as levitated systems and multimode optomechanical arrays or crystals as well as Josephson-based optomechanical systems.

arXiv:2201.02592•Physical Review A•Aug 11, 2022•24 citations

Squeezing enhanced homodyne weak force sensing in cavity optomechanics

Madan Mohan Mahana, Sanket Das, Tarak Nath Dey

Cavity optomechanical systems have emerged as a promising platform for quantum sensing. Quantum mechanics imposes a standard quantum limit (SQL) on the force-sensitivity for the standard homodyne phase quadrature measurement of the cavity's output field. In this paper, we investigate ways to enhance weak force sensitivity beyond SQL by employing a variational homodyne quadrature readout and quantum squeezing. Our study reveals a remarkable improvement in the force sensitivity of a cavity optomechanical sensor at a suitable homodyne angle, compared with standard phase quadrature detection of the cavity output field within a specific frequency band. We further demonstrate improved force sensitivity via intra-cavity squeezing (ICS) or injected external squeezing (IES) of the cavity mode. Both variational homodyne readout and quantum squeezing induce quantum correlations between the amplitude and phase quadratures of the cavity's output field, thereby improving force sensitivity. Our results suggest that IES is preferable to ICS for sub-SQL force sensing with system stability and lower probe power requirements. The squeezing-enhanced variational homodyne detection scheme can enable high-precision quantum sensing across various hybrid quantum platforms.

quant-pharXiv:2606.28007•Jun 29, 2026•0 citations

Force sensing in a dissipative optomechanical system in the presence of parametric amplifier’s pump phase noise

Asad Mehmood, Sajid Qamar, Shahid Qamar

Abstract In this paper, we study the effects of phase noise associated with the pump laser which drives the parametric amplifier (PA) on the detection of a weak classical force acting on a free test mass. The optomechanical system is considered to be dissipatively coupled. The presence of PA in a dissipatively coupled optomechanical system allows to achieve force sensitivity much better than the standard quantum limit (SQL) for a wider range of detection frequency (Huang and Agarwal 2017 Phys. Rev. A 95 023844). However, our results show that the introduction of pump phase noise into the system strongly effects the force sensing. Interestingly, we find that for an optimum choice of different parameters, one can still realize force sensing better than SQL even in the presence of pump phase noise of PA.

Physica Scripta•Apr 9, 2019•11 citations

Force sensing based on coherent quantum noise cancellation in a hybrid optomechanical cavity with squeezed-vacuum injection

Ali Motazedifard, F. Bemani, M. H. Naderi +2 more

We propose and analyse a feasible experimental scheme for a quantum force sensor based on the elimination of backaction noise through coherent quantum noise cancellation (CQNC) in a hybrid atom-cavity optomechanical setup assisted with squeezed vacuum injection. The force detector, which allows for a continuous, broadband detection of weak forces well below the standard quantum limit (SQL), is formed by a single optical cavity simultaneously coupled to a mechanical oscillator and to an ensemble of ultracold atoms. The latter acts as a negative-mass oscillator so that atomic noise exactly cancels the backaction noise from the mechanical oscillator due to destructive quantum interference. Squeezed vacuum injection enforces this cancellation and allows sub-SQL sensitivity to be reached in a very wide frequency band, and at much lower input laser powers.

arXiv:1603.09399•New Journal of Physics•Jul 22, 2016•123 citations

Optical phase measurement beyond the shot noise limit using optical spin squeezed state

Takafumi Ono

Quantum metrology enables us to estimate optical phase shifts beyond the shot noise limit. Applications include quantum-enhanced biological measurement [1], microscopy [2] and gravitational wave detection[3]. For two-mode N-photon system, the NOON state can achieve the highest possible phase sensitivity where multi-photon coherence between two states significantly contributes to improving the phase sensitivity. Another alternative approach to improve the phase sensitivity by use of squeezed states. Squeezing is usually characterized by reducing the quantum noise of desired observable at the expense of increasing the quantum noise for its non-commute partner. Because shot-noise limits the phase sensitivity of any classical states, the reduced quantum noise can be used for improving the phase sensitivity. Here we experimentally study the phase sensitivity of an optical spin-squeezed state by using linear optics. We generated the optical spin-squeezed state using one photon subtraction from a down converted photon source. To implement the sub-shot noise measurement, we used multiplexed photon number resolving detectors so that we can reconstruct the photon number statistics of the state. In the talk, we will analyse the generated state in terms of both squeezing and phase sensitivity by using Fisher information.

•Jan 1, 2016•0 citations

Overcoming detection loss and noise in squeezing-based optical sensing

Gaetano Frascella, Sascha Agne, Farid Ya. Khalili +1 more

Abstract Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. Squeezed states of atoms and light improve the sensing of the phase, magnetic field, polarization, mechanical displacement. They promise to considerably increase signal-to-noise ratio in imaging and spectroscopy, and are already used in real-life gravitational-wave detectors. But despite being more robust than other states, they are still very fragile, which narrows the scope of their application. In particular, squeezed states are useless in measurements where the detection is inefficient or the noise is high. Here, we experimentally demonstrate a remedy against loss and noise: strong noiseless amplification before detection. This way, we achieve loss-tolerant operation of an interferometer fed with squeezed and coherent light. With only 50% detection efficiency and with noise exceeding the level of squeezed light more than 50 times, we overcome the shot-noise limit by 6 dB. Sub-shot-noise phase sensitivity survives up to 87% loss. Application of this technique to other types of optical sensing and imaging promises a full use of quantum resources in these fields.

arXiv:2005.08843•npj Quantum Information•May 12, 2021•68 citations
We investigate the force measurement sensitivity in a squeezed dissipative optomechanics within the free-mass regime under the influence of shot noise (SN) from the photon number fluctuations, laser phase noise from the pump laser, thermal noise from the environment, and optical losses from outcoupling and detection inefficiencies. Generally, squeezed light could generate a reduced SN on the squeezed quadrature and an enlarged quantum backaction noise (QBA) due to the antisqueezed conjugate quadrature. With an appropriate choice of phase angle in homodyne detection, QBA is cancellable, leading to an exponentially improved measurement sensitivity for the SN-dominated regime. By now, the effects of laser phase noise that is proportional to laser power emerge. The balance between squeezed SN and phase noise can lead to an sub-SQL sensitivity at an exponentially lower input power. However, the improvement by squeezing is limited by optical losses because high sensitivity is delicate and easily destroyed by optical losses.
In this paper we propose an experimentally viable scheme to enhance the sensitivity of force detection in a hybrid optomechanical setup assisted by squeezed vacuum injection, beyond the standard quantum limit (SQL). The scheme is based on a combination of the coherent quantum noise cancellation (CQNC) strategy with a variational homodyne detection of the cavity output spectrum in which the phase of the local oscillator is optimized. In CQNC, realizing a negative-mass oscillator in the system leads to exact cancellation of the backaction noise from the mechanics due to destructive quantum interference. Squeezed vacuum injection enhances this cancellation and allows sub-SQL sensitivity to be reached in a wide frequency band and at much lower input laser powers. We show here that the adoption of variational homodyne readout enables us to enhance this noise cancellation up to 40dB40\phantom{\rule{3.33333pt}{0ex}}\mathrm{dB}40dB compared to the standard case of detection of the optical output phase quadrature, leading to a remarkable force sensitivity of the order of ${10}^{\ensuremath{-}19}\phantom{\rule{0.28em}{0ex}}\mathrm{N}/\sqrt{\mathrm{Hz}}$, about 7070%70 enhancement compared to the standard case. Moreover, we show that at nonzero cavity detuning, the signal response can be amplified at a level three to five times larger than that in the standard case without variational homodyne readout, improving the signal-to-noise ratio. Finally, the variational readout CQNC developed in this paper may be applied to other optomechanical-like platforms such as levitated systems and multimode optomechanical arrays or crystals as well as Josephson-based optomechanical systems.
Cavity optomechanical systems have emerged as a promising platform for quantum sensing. Quantum mechanics imposes a standard quantum limit (SQL) on the force-sensitivity for the standard homodyne phase quadrature measurement of the cavity's output field. In this paper, we investigate ways to enhance weak force sensitivity beyond SQL by employing a variational homodyne quadrature readout and quantum squeezing. Our study reveals a remarkable improvement in the force sensitivity of a cavity optomechanical sensor at a suitable homodyne angle, compared with standard phase quadrature detection of the cavity output field within a specific frequency band. We further demonstrate improved force sensitivity via intra-cavity squeezing (ICS) or injected external squeezing (IES) of the cavity mode. Both variational homodyne readout and quantum squeezing induce quantum correlations between the amplitude and phase quadratures of the cavity's output field, thereby improving force sensitivity. Our results suggest that IES is preferable to ICS for sub-SQL force sensing with system stability and lower probe power requirements. The squeezing-enhanced variational homodyne detection scheme can enable high-precision quantum sensing across various hybrid quantum platforms.
Abstract In this paper, we study the effects of phase noise associated with the pump laser which drives the parametric amplifier (PA) on the detection of a weak classical force acting on a free test mass. The optomechanical system is considered to be dissipatively coupled. The presence of PA in a dissipatively coupled optomechanical system allows to achieve force sensitivity much better than the standard quantum limit (SQL) for a wider range of detection frequency (Huang and Agarwal 2017 Phys. Rev. A 95 023844). However, our results show that the introduction of pump phase noise into the system strongly effects the force sensing. Interestingly, we find that for an optimum choice of different parameters, one can still realize force sensing better than SQL even in the presence of pump phase noise of PA.
We propose and analyse a feasible experimental scheme for a quantum force sensor based on the elimination of backaction noise through coherent quantum noise cancellation (CQNC) in a hybrid atom-cavity optomechanical setup assisted with squeezed vacuum injection. The force detector, which allows for a continuous, broadband detection of weak forces well below the standard quantum limit (SQL), is formed by a single optical cavity simultaneously coupled to a mechanical oscillator and to an ensemble of ultracold atoms. The latter acts as a negative-mass oscillator so that atomic noise exactly cancels the backaction noise from the mechanical oscillator due to destructive quantum interference. Squeezed vacuum injection enforces this cancellation and allows sub-SQL sensitivity to be reached in a very wide frequency band, and at much lower input laser powers.
Quantum metrology enables us to estimate optical phase shifts beyond the shot noise limit. Applications include quantum-enhanced biological measurement [1], microscopy [2] and gravitational wave detection[3]. For two-mode N-photon system, the NOON state can achieve the highest possible phase sensitivity where multi-photon coherence between two states significantly contributes to improving the phase sensitivity. Another alternative approach to improve the phase sensitivity by use of squeezed states. Squeezing is usually characterized by reducing the quantum noise of desired observable at the expense of increasing the quantum noise for its non-commute partner. Because shot-noise limits the phase sensitivity of any classical states, the reduced quantum noise can be used for improving the phase sensitivity. Here we experimentally study the phase sensitivity of an optical spin-squeezed state by using linear optics. We generated the optical spin-squeezed state using one photon subtraction from a down converted photon source. To implement the sub-shot noise measurement, we used multiplexed photon number resolving detectors so that we can reconstruct the photon number statistics of the state. In the talk, we will analyse the generated state in terms of both squeezing and phase sensitivity by using Fisher information.
Abstract Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. Squeezed states of atoms and light improve the sensing of the phase, magnetic field, polarization, mechanical displacement. They promise to considerably increase signal-to-noise ratio in imaging and spectroscopy, and are already used in real-life gravitational-wave detectors. But despite being more robust than other states, they are still very fragile, which narrows the scope of their application. In particular, squeezed states are useless in measurements where the detection is inefficient or the noise is high. Here, we experimentally demonstrate a remedy against loss and noise: strong noiseless amplification before detection. This way, we achieve loss-tolerant operation of an interferometer fed with squeezed and coherent light. With only 50% detection efficiency and with noise exceeding the level of squeezed light more than 50 times, we overcome the shot-noise limit by 6 dB. Sub-shot-noise phase sensitivity survives up to 87% loss. Application of this technique to other types of optical sensing and imaging promises a full use of quantum resources in these fields.