Abstract In this paper, we study the effects of phase noise associated with the pump laser which drives the parametric amplifier (PA) on the detection of a weak classical force acting on a free test mass. The optomechanical system is considered to be dissipatively coupled. The presence of PA in a dissipatively coupled optomechanical system allows to achieve force sensitivity much better than the standard quantum limit (SQL) for a wider range of detection frequency (Huang and Agarwal 2017 Phys. Rev. A 95 023844). However, our results show that the introduction of pump phase noise into the system strongly effects the force sensing. Interestingly, we find that for an optimum choice of different parameters, one can still realize force sensing better than SQL even in the presence of pump phase noise of PA.
Abstract In this paper, we study the effects of phase noise associated with the pump laser which drives the parametric amplifier (PA) on the detection of a weak classical force acting on a free test mass. The optomechanical system is considered to be dissipatively coupled. The presence of PA in a dissipatively coupled optomechanical system allows to achieve force sensitivity much better than the standard quantum limit (SQL) for a wider range of detection frequency (Huang and Agarwal 2017 Phys. Rev. A 95 023844). However, our results show that the introduction of pump phase noise into the system strongly effects the force sensing. Interestingly, we find that for an optimum choice of different parameters, one can still realize force sensing better than SQL even in the presence of pump phase noise of PA.
We theoretically investigate quantum measurement noise in a hybrid optomechanical system, focusing on radiation-pressure back-action and its impact on force sensing. The setup consists of an optomechanical cavity with a movable mirror, a fixed semitransparent mirror, an ensemble of quantum dots (QDs) coupled to the cavity mode, and an intracavity optical parametric amplifier (OPA). We show how the QD-induced response, together with the system nonlinearity, modifies the noise spectral density and thereby improves the force measurement sensitivity. In this setup, coherent quantum noise cancellation (CQNC) can completely remove the back-action noise. In addition, increasing the OPA pump gain enables sensitivity beyond the standard quantum limit (SQL) at reduced laser power. These combined effects allow weak-force sensing beyond the SQL.
We investigate the reduction of measurement-added noise in force sensing by analyzing its power spectral density (PSD) within a hybrid optomechanical system. The setup is comprised of an optomechanical cavity equipped with a movable mirror which acts as the mechanical oscillator, a stationary semi-transparent mirror, a superconducting qubit, and an optical parametric amplifier (OPA). By utilizing the concept of coherent quantum noise cancellation (CQNC), we derive the conditions necessary for complete cancellation of back-action force, thereby enhancing force sensitivity. Furthermore, with the gradual increase in the OPA pump gains, we suppress the sensitivity beyond the standard quantum limit (SQL) at a lower value of laser power. The removal of back-action noise, along with the reduction of shot noise, improves force detection capabilities, thereby surpassing the standard quantum limit associated with weak force detection.
We theoretically investigate quantum measurement noise in a hybrid optomechanical system, focusing on radiation pressure back action and its impact on force sensing. The setup consists of an optomechanical cavity with a movable mirror, a fixed semi transparent mirror, an ensemble of quantum dots (QD) coupled to the cavity mode, and an intracavity optical parametric amplifier (OPA). We show how the QD induced response, together with the system nonlinearity, modifies the noise spectral density and thereby improves the force measurement sensitivity. In this setup, coherent quantum noise cancellation (CQNC) can completely remove the back action noise. In addition, increasing the OPA pump gain enables sensitivity beyond the standard quantum limit (SQL) at reduced laser power. These combined effects allow weak force sensing beyond the SQL.
We investigate the reduction of measurement-added noise in force sensing by analyzing its power spectral density (PSD) within a hybrid optomechanical system. The setup comprises of an optomechanical cavity equipped with a movable mirror which acts as the mechanical oscillator, a stationary semi-transparent mirror, a superconducting qubit, and an optical parametric amplifier (OPA). By utilizing the concept of coherent quantum noise cancellation (CQNC), we derive the conditions necessary for complete cancellation of back-action force, thereby enhancing force sensitivity. Furthermore, with the gradual increase in the OPA pump gains, we suppress the sensitivity beyond the standard quantum limit (SQL) at a lower value of laser power. The removal of back-action noise, along with the reduction of shot noise, improves force detection capabilities, thereby surpassing the standard quantum limit associated with weak force detection.
ABSTRACT The sensitivity of optomechanical sensors is fundamentally constrained by the combined effects of shot noise and quantum back‐action. Here we show that the joint action of cross‐Kerr nonlinearity and an optical parametric amplifier (OPA) can effectively suppress these noises. By tailoring the cross‐Kerr strength, the force‐sensing sensitivity can surpass the standard quantum limit (SQL), while an optimal driving power broadens the detection bandwidth. We further find that the system becomes unstable when the detuning falls below . Importantly, the inclusion of an OPA enhances robustness against thermal fluctuations, allowing the sensitivity of force measurement to surpass the SQL even at temperatures up to 300 K. A detailed noise analysis reveals that cross‐Kerr nonlinearity predominantly suppresses back‐action noise, whereas the OPA provides a strong reduction of shot noise. These results establish a promising hybrid strategy for realizing optomechanical sensors that combine high sensitivity with thermal resilience, with broad applications ranging from medical diagnostics to gravitational‐wave astronomy.
We investigate the force measurement sensitivity in a squeezed dissipative optomechanics within the free-mass regime under the influence of shot noise (SN) from the photon number fluctuations, laser phase noise from the pump laser, thermal noise from the environment, and optical losses from outcoupling and detection inefficiencies. Generally, squeezed light could generate a reduced SN on the squeezed quadrature and an enlarged quantum backaction noise (QBA) due to the antisqueezed conjugate quadrature. With an appropriate choice of phase angle in homodyne detection, QBA is cancellable, leading to an exponentially improved measurement sensitivity for the SN-dominated regime. By now, the effects of laser phase noise that is proportional to laser power emerge. The balance between squeezed SN and phase noise can lead to an sub-SQL sensitivity at an exponentially lower input power. However, the improvement by squeezing is limited by optical losses because high sensitivity is delicate and easily destroyed by optical losses.