Optics Express

Integrated multiple wavelength stabilization on a multi-channel cavity for a transportable optical clock

Shaomao Wang, Jian Zhong Cao, Jinbo Yuan, Daoxin Liu, Hualin Shu, Xue-Ren Huang

Published Mar 30, 2020• 31 citations
Publisher

Abstract

We present a simple, compact, and efficient scheme for integrated multiple wavelength stabilization and continuous operation of a transportable 40Ca+ optical clock using a multi-channel cavity. The fractional frequency instability of 729 nm clock laser is ∼ 1.5 ×10−15 at 10 s with an approximate linewidth of 1 Hz. Meanwhile, frequency fluctuations of all the other lasers are less than ± 330 kHz/day. The one-day stability of this clock is measured as ∼ 5 ×10−17 through 72 h continuous operation. This scheme is potentially useful for the realization of next-generation transportable optical clocks and other metrological systems.

DOI
10.1364/oe.383115

Related papers

A compact, transportable optical clock with 1×10−17 uncertainty and its absolute frequency measurement

Jian Zhong Cao, Jinbo Yuan, Shaomao Wang +13 more

We report a robust, compact, and transportable optical clock (TOC-729-2) based on a trapped single 40Ca+ ion with a systematic uncertainty of 1.1×10−17, which is limited by the black-body radiation shift uncertainty at room temperature. By comparing it with the previous transportable optical clock (TOC-729-1) similar but completely independent, the instability was measured to be better than 1.2×10−14/τ. Benefiting from the modular and integrated design, this TOC was constructed in a volume of ∼0.33 m3 excluding the controlling electronics in 19-in. racks. After being moved ∼1200 km away by express delivery, the single-ion signal was restored within 24 h. With the TOC uptime of 92% in 35-day period, the absolute frequency of the 729 nm transition of 40Ca+ was measured using a satellite link to International Atomic Time (TAI) to provide traceability to the SI second, and the result is 411 042 129 776 400.15(22) Hz, corresponding to a relative uncertainty of 5.3×10−16.

Applied Physics Letters•Jan 31, 2022•22 citations

Miniaturized optical frequency reference for next-generation portable optical clocks

Vincent N. Maurice, Zachary L. Newman, Susannah M. Dickerson +7 more

Optical frequency standards, or lasers stabilized to atomic or molecular transitions, are widely used in length metrology and laser ranging, provide a backbone for optical communications and lie at the heart of next-generation optical atomic clocks. Here we demonstrate a compact, low-power optical frequency reference based on the Doppler-free, two-photon transition in rubidium-87 at 778 nm implemented on a micro-optics breadboard. Our optical reference achieves a fractional frequency instability of 2.9×10−12/ τ for averaging times τ less than 103 s, has a volume of ≈35 cm3 and operates on ≈450 mW of electrical power. The advanced optical integration presented here demonstrates a key step towards the development of compact optical clocks and the broad dissemination of SI-traceable wavelength references.

arXiv:2003.13172•Optics Express•Jul 15, 2020•71 citations

Frequency Locking and Power Enhancement by Coherent Addition of a Clock Laser for a Portable Multi-40Ca+ Optical Clock

Akira Nagano, U. Tanaka, Kazuhiro Hayasaka

Summary—We construct a frequency locking system for a portable multi-ion optical clock and develop a clock laser whose power is enhanced by the coherent addition method. We reduce the feedback cycle time down to 50 ms, which realizes short-term stabilization with a commercial confocal cavity. To excite the clock transition at 729 nm of multiple ions, we perform coherent addition of 1458-nm optical amplifier outputs and obtain 100 mW at 729 nm by second-harmonic generation.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 15, 2023•0 citations

Design of a Board-Level Integrated Multi-Channel Radio Frequency Source for the Transportable 40Ca+ Ion Optical Clock

Bin Wang, Yuanhang Yang, Huaqing Zhang +5 more

As one of the most accurate instruments in history, the optical clock will be used as the measuring equipment for the next generation of seconds. The demand for miniaturization of optical clock is progressively urgent. In this paper, a multi-channel radio frequency module with a 20% volume of the commercial module is designed and implemented for the transportable 40Ca+ ion optical clock. Based on the double crystal oscillator interlocking technique,1 GHz low-phase noise reference source is developed for direct digital synthesis. By simulation and optimization of the signal link design, a frequency range of the low-phase noise RF signal can reach 0-400 MHz with a 4 μHz resolution. Through two-stage power amplified with different kinds of filters, it can get an output power up to +33 dBm (2 W) at 100 MHz with a 25 dBc/Hz phase noise lower than the commercial module at 1 Hz, and its third harmonic suppression ratio has been reduced by more than 20 dBm at the frequency point of 300 MHz. This multi-channel RF module is used for the power stability and timing control test of 729 nm clock laser, to meet the requirements of the transportable 40Ca+ optical clock. Without this, this module can also be applied to other quantum systems such as quantum absolute gravimeter, quantum gyro and quantum computer.

Sensors•Feb 10, 2025•0 citations

High-performance laser system for compact cold-atom optical clock

B. X. Yu, Bowen Yang, Haojie Zhao +6 more

We demonstrate a straightforward frequency-locking technique that employs external modulation saturation absorption spectroscopy to achieve a high-performance 780 nm laser system. By externally modulating the laser frequency through a fiber electro-optic modulator, this scheme can stabilize multiple transitions of the 87Rb D2 line with excellent performance. Experimental results establish fractional frequency instability of 2.21 × 10-13 at 1 s with a linewidth of 1.46 kHz for the cycling transition 5S1/2(Fg = 2) → 5P3/2(Fe = 3). Notably, we have locked the system to the repumping transition 5S1/2(Fg = 1) → 5P3/2(Fe = 2), achieving a record-low instability of 1.98 × 10-12 at 1 s averaging time. This simplified laser system, featuring exceptional short-term frequency stability and multi-frequency locking capability, serves as a critical subsystem for the compact cold-atom optical clock, enabling advanced precision metrology applications. Furthermore, its metrological performance enables immediate applications in other quantum sensors, such as Rydberg electrometry, atomic magnetometry, and matter-wave interferometry.

Review of Scientific Instruments•Oct 1, 2025•0 citations

A transportable 40 Ca + optical clock with 1.6 × 10 − 15 / τ frequency instability enabled by improved magnetic shielding and comb-based frequency stability transfer

Ruming Hu, Zixiao Ma, Baolin Zhang +12 more

Abstract Here, we develop a compact multilayer magnetic shield for a transportable optical clock, achieving shielding factors of up to 10 5 . To improve the frequency stability of the transportable optical clock, we improved the magnetic-field environment of a transportable 40 Ca + ion optical clock (TCIOC) using the newly developed magnetic shielding system and reduced the clock-laser frequency noise by transferring the stability of an ultrastable reference laser through an optical frequency comb. These improvements enabled the coherent interrogation time to be extended from 40 ms to 320 ms . A time-interleaved self-comparison yielded a measured short-term fractional frequency instability of 1.6 × 10 − 15 / τ , close to the estimated quantum projection noise-limited instability of 1.18 × 10 − 15 / τ . Meanwhile, the uncertainty contributions associated with the DC second-order Zeeman shift and the servo error were reduced to 1.1 × 10 − 21 and 4.5 × 10 − 19 . These results provide a practical basis for further improving the performance of transportable optical clocks.

New Journal of Physics•Aug 20, 2026•0 citations
We present a simple, compact, and efficient scheme for integrated multiple wavelength stabilization and continuous operation of a transportable 40Ca+ optical clock using a multi-channel cavity. The fractional frequency instability of 729 nm clock laser is ∼ 1.5 ×10−15 at 10 s with an approximate linewidth of 1 Hz. Meanwhile, frequency fluctuations of all the other lasers are less than ± 330 kHz/day. The one-day stability of this clock is measured as ∼ 5 ×10−17 through 72 h continuous operation. This scheme is potentially useful for the realization of next-generation transportable optical clocks and other metrological systems.
We report a robust, compact, and transportable optical clock (TOC-729-2) based on a trapped single 40Ca+ ion with a systematic uncertainty of 1.1×10−17, which is limited by the black-body radiation shift uncertainty at room temperature. By comparing it with the previous transportable optical clock (TOC-729-1) similar but completely independent, the instability was measured to be better than 1.2×10−14/τ. Benefiting from the modular and integrated design, this TOC was constructed in a volume of ∼0.33 m3 excluding the controlling electronics in 19-in. racks. After being moved ∼1200 km away by express delivery, the single-ion signal was restored within 24 h. With the TOC uptime of 92% in 35-day period, the absolute frequency of the 729 nm transition of 40Ca+ was measured using a satellite link to International Atomic Time (TAI) to provide traceability to the SI second, and the result is 411 042 129 776 400.15(22) Hz, corresponding to a relative uncertainty of 5.3×10−16.
Optical frequency standards, or lasers stabilized to atomic or molecular transitions, are widely used in length metrology and laser ranging, provide a backbone for optical communications and lie at the heart of next-generation optical atomic clocks. Here we demonstrate a compact, low-power optical frequency reference based on the Doppler-free, two-photon transition in rubidium-87 at 778 nm implemented on a micro-optics breadboard. Our optical reference achieves a fractional frequency instability of 2.9×10−12/ τ for averaging times τ less than 103 s, has a volume of ≈35 cm3 and operates on ≈450 mW of electrical power. The advanced optical integration presented here demonstrates a key step towards the development of compact optical clocks and the broad dissemination of SI-traceable wavelength references.
As one of the most accurate instruments in history, the optical clock will be used as the measuring equipment for the next generation of seconds. The demand for miniaturization of optical clock is progressively urgent. In this paper, a multi-channel radio frequency module with a 20% volume of the commercial module is designed and implemented for the transportable 40Ca+ ion optical clock. Based on the double crystal oscillator interlocking technique,1 GHz low-phase noise reference source is developed for direct digital synthesis. By simulation and optimization of the signal link design, a frequency range of the low-phase noise RF signal can reach 0-400 MHz with a 4 μHz resolution. Through two-stage power amplified with different kinds of filters, it can get an output power up to +33 dBm (2 W) at 100 MHz with a 25 dBc/Hz phase noise lower than the commercial module at 1 Hz, and its third harmonic suppression ratio has been reduced by more than 20 dBm at the frequency point of 300 MHz. This multi-channel RF module is used for the power stability and timing control test of 729 nm clock laser, to meet the requirements of the transportable 40Ca+ optical clock. Without this, this module can also be applied to other quantum systems such as quantum absolute gravimeter, quantum gyro and quantum computer.
We demonstrate a straightforward frequency-locking technique that employs external modulation saturation absorption spectroscopy to achieve a high-performance 780 nm laser system. By externally modulating the laser frequency through a fiber electro-optic modulator, this scheme can stabilize multiple transitions of the 87Rb D2 line with excellent performance. Experimental results establish fractional frequency instability of 2.21 × 10-13 at 1 s with a linewidth of 1.46 kHz for the cycling transition 5S1/2(Fg = 2) → 5P3/2(Fe = 3). Notably, we have locked the system to the repumping transition 5S1/2(Fg = 1) → 5P3/2(Fe = 2), achieving a record-low instability of 1.98 × 10-12 at 1 s averaging time. This simplified laser system, featuring exceptional short-term frequency stability and multi-frequency locking capability, serves as a critical subsystem for the compact cold-atom optical clock, enabling advanced precision metrology applications. Furthermore, its metrological performance enables immediate applications in other quantum sensors, such as Rydberg electrometry, atomic magnetometry, and matter-wave interferometry.
Abstract Here, we develop a compact multilayer magnetic shield for a transportable optical clock, achieving shielding factors of up to 10 5 . To improve the frequency stability of the transportable optical clock, we improved the magnetic-field environment of a transportable 40 Ca + ion optical clock (TCIOC) using the newly developed magnetic shielding system and reduced the clock-laser frequency noise by transferring the stability of an ultrastable reference laser through an optical frequency comb. These improvements enabled the coherent interrogation time to be extended from 40 ms to 320 ms . A time-interleaved self-comparison yielded a measured short-term fractional frequency instability of 1.6 × 10 − 15 / τ , close to the estimated quantum projection noise-limited instability of 1.18 × 10 − 15 / τ . Meanwhile, the uncertainty contributions associated with the DC second-order Zeeman shift and the servo error were reduced to 1.1 × 10 − 21 and 4.5 × 10 − 19 . These results provide a practical basis for further improving the performance of transportable optical clocks.