Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Radiophysics and Quantum Electronics

A Study of a Narrow-Band Receiving System of Cold-Electron Bolometers for the 220 and 240 GHz Channels using an Oscillator Based on the High-Temperature YBCO Superconductor

L. S. Revin, Dmitry A. Pimanov, Anton V Blagodatkin, Anna V. Gordeeva, V. O. Zbrozhek, Dmitry V. Masterov, Alexey E. Parafin, Sergey A. Pavlov, A. L. Pankratov, Igor V. Rakut’, I. A. Fil’kin, Alexander V. Chiginev, L. S. Kuzmin, S. Masi, P. de Bernardis

Published Dec 1, 2019• 3 citations
Publisher
DOI
10.1007/s11141-020-10002-6

Related papers

Superconducting antenna-coupled YBCO bolometers at submillimeter wavelengths

A. Scheuring, Petra Probst, C. Dischke +2 more

•Jan 1, 2010•0 citations

A Bunch of YBCO Josephson Generators for the Analysis of Resonant Cold-Electron Bolometers

L. S. Revin, Dmitry V. Masterov, Alexey E. Parafin +8 more

The resonant properties of Cold-Electron Bolometers (CEBs) located at a 0.3 K cryostat plate are measured using a 50 μm long high-temperature YBa2Cu3O7−δ (YBCO) Josephson junction oscillator, placed on a 2.7 K plate of the same cryostat. For these purposes, a bunch of YBCO Josephson oscillators with various lengths of dipole antennas and overlapping generation bands has been developed and investigated in 50–500 GHz frequency range. Two setups of Josephson junction placement were compared, and as a result, various narrow-band receiving systems with CEBs have been measured, demonstrating the feasibility of the presented approach.

Applied Sciences•Nov 23, 2022•5 citations

Terahertz spectroscopy by Josephson oscillator and cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin, T. Claeson +2 more

For sensitive wideband spectroscopy at THz frequencies with performance better than for Fourier Transform Spectrometer, one needs a wide-range electrically tunable, narrow linewidth THz source, and a sensitive broadband detector. To obtain a low noise level of sensor we use a superconducting normal metal cold electron bolometer (CEB). A voltage response of the bolometer is 4.108 V/W and an amplifier-limited technical noise equivalent power of the bolometer is 1.25.10-17 W/Hz1/2. The wide band electrically tuned terahertz band cryogenic oscillator is a Josephson junction. Contrary to conventional Josephson junctions based on niobium, and naturally limited in frequency by energy gap of about 700 GHz, the high critical temperature YBaCuO junctions can extend this limit by an order of magnitude. At 4 K such oscillators can radiate at frequencies exceeding 2 THz. Signals received by bolometers integrated with double-dipole and log-periodic antennas and irradiated by the Josephson oscillator show in our experiments the high frequency response corresponding to an oscillation frequency of up to 1.75 THz. Such cryogenic terahertz network analyzer is suitable for low-signal spectral evaluation of cryogenic detectors, quasioptical sub-mm cryogenic filters, planar antennas with planar microwave filters, integrated structures comprising such elements, and arrays of cryogenic receivers.

•Jan 1, 2004•0 citations

A Superconducting Hot Electron Bolometer Mixer for 530 GHz

Anders J. Skalare, William R. McGrath, B. Bumble +4 more

Softwaretechnik-Trends•May 10, 1994•7 citations

IF properties of YBCO hot-electron bolometer mixers for millimeter-wave radiation

Takashi Uchida, Yoshizumi Yasuoka, Katsumi Suzuki

Physica C Superconductivity•Aug 1, 2002•3 citations

Gain-Bandwidth Characteristics of High-Tc Superconducting Millimeter-Wave Hot-Electron Bolometer Mixers

Chao-Te Li, Bascom S. Deaver, Robert M. Weikle +3 more

The conversion gain bandwidth characteristics of millimeter-wave mixers using high-Tc superconducting YBa2Cu307 (YBCO) thin films are presented. The YBCO films are patterned into latticecooled hot-electron bolometers (HEB) coupled to an integrated antenna and transmission line. Direct heterodyne and homodyne down-conversion measurements using local-oscillator frequencies of 75 GHz and 585 GHz show overall conversion gains of -35 dB, which includes a -18 dB coupling loss. The gain bandwidth shows a simple Lorentzian roll-off with -3 dB point of 5 to 8 GHz. No second plateau in the gain spectrum has been observed, in contrast to other reports. The effective volume of the HEB is believed to be significantly smaller than the physical dimensions of the device. Gershenzon, et al. 1 first proposed the design of a lattice-cooled superconducting hot-electron bolometer (HEB) for use as a low-power, wide-band-width heterodyne mixer at millimeter and submillimeter-wave frequencies. This idea has been successfully implemented using NbN , which shows a conversion gain as high as -15 dB using 1 1.tW of pump power at a temperature of 4.2 K. The ultimate speed and bandwidth of the lattice-cooled HEB is determined by the electron-phonon scattering rate. For this reason, Gershenzon 3 suggested that the high normal-state resistivity of the high-Tc superconductor YBa2Cu307 (YBCO) could indicate a very fast electron inelastic scattering, rate and so make this material an ideal candidate to produce a very wide instantaneous bandwidth lattice-cooled HEB operating at 77 K. The first reports of such mixers at 1.5 gm (Ref. 4) and 9.6 gm (Ref. 5) wavelengths showed a very low intrinsic conversion gain of -77 dB (excluding coupling losses) using a relatively large 0.3 mW of absorbed LO power. However, the gain bandwidth showed a twoplateau structure. A low frequency plateau near -77 dB rolled off near 1 GHz intermediate frequency (IF) but gave way to a second plateau near -90 dB that extended to at least 18 GHz, the upper limit of the measurement. Karasik, et al., have done extensive calculations on the conversion gain properties of lattice-cooled HEB mixers for different mixer dimensions, using a two-temperature model. They found that the conversion gain increases

•Mar 1, 1998•1 citation
The resonant properties of Cold-Electron Bolometers (CEBs) located at a 0.3 K cryostat plate are measured using a 50 μm long high-temperature YBa2Cu3O7−δ (YBCO) Josephson junction oscillator, placed on a 2.7 K plate of the same cryostat. For these purposes, a bunch of YBCO Josephson oscillators with various lengths of dipole antennas and overlapping generation bands has been developed and investigated in 50–500 GHz frequency range. Two setups of Josephson junction placement were compared, and as a result, various narrow-band receiving systems with CEBs have been measured, demonstrating the feasibility of the presented approach.
For sensitive wideband spectroscopy at THz frequencies with performance better than for Fourier Transform Spectrometer, one needs a wide-range electrically tunable, narrow linewidth THz source, and a sensitive broadband detector. To obtain a low noise level of sensor we use a superconducting normal metal cold electron bolometer (CEB). A voltage response of the bolometer is 4.108 V/W and an amplifier-limited technical noise equivalent power of the bolometer is 1.25.10-17 W/Hz1/2. The wide band electrically tuned terahertz band cryogenic oscillator is a Josephson junction. Contrary to conventional Josephson junctions based on niobium, and naturally limited in frequency by energy gap of about 700 GHz, the high critical temperature YBaCuO junctions can extend this limit by an order of magnitude. At 4 K such oscillators can radiate at frequencies exceeding 2 THz. Signals received by bolometers integrated with double-dipole and log-periodic antennas and irradiated by the Josephson oscillator show in our experiments the high frequency response corresponding to an oscillation frequency of up to 1.75 THz. Such cryogenic terahertz network analyzer is suitable for low-signal spectral evaluation of cryogenic detectors, quasioptical sub-mm cryogenic filters, planar antennas with planar microwave filters, integrated structures comprising such elements, and arrays of cryogenic receivers.
The conversion gain bandwidth characteristics of millimeter-wave mixers using high-Tc superconducting YBa2Cu307 (YBCO) thin films are presented. The YBCO films are patterned into latticecooled hot-electron bolometers (HEB) coupled to an integrated antenna and transmission line. Direct heterodyne and homodyne down-conversion measurements using local-oscillator frequencies of 75 GHz and 585 GHz show overall conversion gains of -35 dB, which includes a -18 dB coupling loss. The gain bandwidth shows a simple Lorentzian roll-off with -3 dB point of 5 to 8 GHz. No second plateau in the gain spectrum has been observed, in contrast to other reports. The effective volume of the HEB is believed to be significantly smaller than the physical dimensions of the device. Gershenzon, et al. 1 first proposed the design of a lattice-cooled superconducting hot-electron bolometer (HEB) for use as a low-power, wide-band-width heterodyne mixer at millimeter and submillimeter-wave frequencies. This idea has been successfully implemented using NbN , which shows a conversion gain as high as -15 dB using 1 1.tW of pump power at a temperature of 4.2 K. The ultimate speed and bandwidth of the lattice-cooled HEB is determined by the electron-phonon scattering rate. For this reason, Gershenzon 3 suggested that the high normal-state resistivity of the high-Tc superconductor YBa2Cu307 (YBCO) could indicate a very fast electron inelastic scattering, rate and so make this material an ideal candidate to produce a very wide instantaneous bandwidth lattice-cooled HEB operating at 77 K. The first reports of such mixers at 1.5 gm (Ref. 4) and 9.6 gm (Ref. 5) wavelengths showed a very low intrinsic conversion gain of -77 dB (excluding coupling losses) using a relatively large 0.3 mW of absorbed LO power. However, the gain bandwidth showed a twoplateau structure. A low frequency plateau near -77 dB rolled off near 1 GHz intermediate frequency (IF) but gave way to a second plateau near -90 dB that extended to at least 18 GHz, the upper limit of the measurement. Karasik, et al., have done extensive calculations on the conversion gain properties of lattice-cooled HEB mixers for different mixer dimensions, using a two-temperature model. They found that the conversion gain increases