Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

LPICo

Miniature Dual-Mode Absolute Scalar Magnetometer Based on the Rubidium Isotope 87Rb

H. Korth, Kim Strohbehn, John E. Kitching

Published Oct 1, 2016• 0 citations
OpenAlex

Related papers

Miniature Absolute Scalar Magnetometer Based on the Rubidium Isotope 87Rb

H. Korth, Kim Strohbehn, Francisco J. Tejada +3 more

LPICo•Oct 1, 2012•0 citations

Sensitivity Optimization of a Dual Isotope Rubidium Magnetometer

Rodrigo Peregrinaramirez, Ian Lacey, J. Félix +3 more

Bulletin of the American Physical Society•Oct 29, 2010•0 citations

Towards a miniature atomic scalar magnetometer using a liquid crystal polarization rotator

J. Rutkowski, William Fourcault, F. Bertrand +9 more

Sensors and Actuators A Physical•May 13, 2014•32 citations

Search for an anomalous spin-mass coupling with a dual isotope rubidium comagnetometer

Cesar Rios, J. Félix, Jerlyn L. Swiatlowski +2 more

Bulletin of the American Physical Society•Nov 3, 2012•0 citations

Miniaturized Dual-Beam SERF Magnetometer Using Natural Abundance Rubidium

Jianwei Sheng, Ziao Liu, Xiaoyu Li +3 more

Due to high sensitivity and compactness, spin-exchange relaxation-free (SERF) atomic magnetometers have found widespread applications. These devices rely on alkali atoms to sense magnetic fields, with87Rb being the commonly used isotope. However,87Rb must be extracted from natural abundance rubidium (natRb) through isotopic separation, making it expensive. Replacing87Rb with natRb reduces the cost to approximately just 1%. Nevertheless, it is generally believed that the isotopic mixture of87Rb and85Rb in natRb affects the coherence of the atomic ensemble. Using a dual-beam SERF magnetometer, we systematically compared 3 mm inner-size cubic vapor cells filled with natRb and87Rb. By optimizing the buffer gas pressure and optical parameters, we demonstrate that the natRb magnetometer can achieve performance comparable to that of the87Rb magnetometer. Experimental results show that both cells achieved a sensitivity of 4 1T/Hz1/2. These findings demonstrate that natRb can effectively replace87Rb in miniaturized dual-beam SERF magnetometers, enabling low-cost, high-sensitivity magnetic field measurements.

IEEE International Conference on Electronic Measurement & Instruments•Aug 22, 2025•0 citations

A millimeter-scale atomic magnetometer

Peter D. D. Schwindt, John E. Kitching, Svenja A. Knappe +4 more

Bulletin of the American Physical Society•May 18, 2005•0 citations
Due to high sensitivity and compactness, spin-exchange relaxation-free (SERF) atomic magnetometers have found widespread applications. These devices rely on alkali atoms to sense magnetic fields, with87Rb being the commonly used isotope. However,87Rb must be extracted from natural abundance rubidium (natRb) through isotopic separation, making it expensive. Replacing87Rb with natRb reduces the cost to approximately just 1%. Nevertheless, it is generally believed that the isotopic mixture of87Rb and85Rb in natRb affects the coherence of the atomic ensemble. Using a dual-beam SERF magnetometer, we systematically compared 3 mm inner-size cubic vapor cells filled with natRb and87Rb. By optimizing the buffer gas pressure and optical parameters, we demonstrate that the natRb magnetometer can achieve performance comparable to that of the87Rb magnetometer. Experimental results show that both cells achieved a sensitivity of 4 1T/Hz1/2. These findings demonstrate that natRb can effectively replace87Rb in miniaturized dual-beam SERF magnetometers, enabling low-cost, high-sensitivity magnetic field measurements.