Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Physica Sinica

Miniaturization of physics system in Sr optical clock

Zhao Fang-Jing, Gao Feng, 韩建新 HAN Jian-xin, Zhou Chi-Hua, Meng Jun-Wei, Wang Ye-Bing, Yang Guo, Shougang Zhang, Chang Hong

Published Jan 1, 2018• 4 citations
Publisher

Abstract

The compactness and robustness of the vacuum setup are the major limitations to develop transportable and space-borne optical clocks. The first step in the engineering challenge is to reduce volume and weight with respect to a stationary system. In this paper, we present the realization of a miniaturized vacuum system by building two anti-Helmholtz coils inside the vacuum magneto-optical-trap (MOT) chamber. The built-in coils are specially designed to minimize the distance between the coils, and in this way it is possible to reduce the current needed to realize a typical magnetic gradient of 40 Gs/cm required for blue MOT. When the MOT coil current is 2 A, an axial magnetic field gradient of 43 Gs/cm is obtained in the center of the MOT, which is enough for the first stage Doppler cooling. This novel design allows us to reduce size, weight and power consumption with respect to a traditional laser cooling apparatus, and simultaneously avoid complicating the water cooling equipment. Our vacuum system has a size of 60 cm×20 cm×15 cm, about 1/10 of the original system in the laboratory. In addition, the circularly polarized Zeeman slowing laser is sent to counter propagating atomic beam, and atoms at a few hundred meters per second are now routinely slowed down to velocities of tens of meters per second. As a result, about 16.4% of the atoms are actually trapped into the blue MOT. The final temperature of the blue MOT is approximately 10.6 mK, and the internal diameter is 1.5 mm by observing the expansion of the atoms from the MOT. The populations of cold atoms finally trapped in the MOT are 1.6×106 of 88Sr and 1.5×105 of 87Sr. The 1S0 → 1P1 transition used for the blue MOT is not perfectly closed due to the decay channel of the 5p1P1 → 4d1D2, and a part of atoms are stored in the 3P2 and 3P0 states. To prevent the atoms from losing, 707 and 679 nm repumping lasers are employed to recycle these atoms in the 3P1 state, and then the atoms decay to the ground state 1S0. Now the typical number of loaded atoms dramatically increases by 5 times compared with before. The slowing efficiency of Zeeman slower is also optimized for the operation with deceleration related to the parameter of magnet length, which uses more effectively available magnetic field distribution, in contrast to the usual constant deceleration mode. Our future work will focus on constructing a Zeeman slower combined with permanent magnets or an electric magnet for better tuning of the magnetic field.

DOI
10.7498/aps.67.20172584

Related papers

Compact magneto-optical trap of thulium atoms for a transportable optical clock

Artem A. Golovizin, Dmitry O. Tregubov, D. Mishin +2 more

We have developed a compact vacuum system for laser cooling and spectroscopy of neutral thulium atoms. Compactness is achieved by obviating a classical Zeeman slower section and placing an atomic oven close to a magneto-optical trap (MOT), specifically at the distance of 11 cm. In this configuration, we significantly gained in solid angle of an atomic beam, which is affected by MOT laser beams, and reached 1 million atoms loaded directly in the MOT with only 15 mW of MOT cooling beams net power. By exploiting Zeeman-like deceleration of atoms with an additional laser beam and tailoring the MOT magnetic field gradient with a small magnetic coil, we demonstrated trapping of up to 13 million atoms. These results show great perspective of the developed setup for realizing a compact high-performance optical atomic clock based on thulium atoms.

Optics Express•Sep 3, 2021•22 citations

Efficient loading of thulium atoms in a compact MOT for a transportable optical clock

Artem A. Golovizin, Dmitry O. Tregubov, D. Mishin +2 more

We report on building of a compact vacuum chamber for spectroscopy of ultracold thulium and trapping of up to 13 million atoms. Compactness is achieved by obviating a classical Zeeman slower section and placing an atomic oven close to a magneto-optical trap (MOT), specifically at the distance of 11 cm. In this configuration, we significantly gained in solid angle of an atomic beam, which is affected by MOT laser beams, and reached 1 million atoms loaded directly in the MOT. By exploiting Zeeman-like deceleration of atoms with an additional laser beam, we increased the number of trapped atoms to 6 million. Then we gained an extra factor of 2 by tailoring the MOT magnetic field gradient with an additional small magnetic coil. Demonstrated results show great perspective of the developed setup for realizing a compact high-performance optical atomic clock based on thulium atoms.

arXiv:2105.02145•May 5, 2021•0 citations

Setup of a Transportable Yb Optical Lattice Clock

C. Abou-Jaoudeh

In this thesis, a transportable setup of an Yb atomic source for a lattice optical clock is built and characterized. All three laser setups for cooling and trapping the Yb atoms, together with the vacuum system, are contained on a transportable optical table. The preparation of the atomic sample before doing spectroscopy on the clock transition starts by slowing the atoms in the Zeeman slower. This is followed by trapping the atoms in the pre-cooling and the post-cooling MOTs, before loading the atoms into the optical lattice. Slowing and pre-cooling the atoms is done using the strong transition at 399 nm. This cools the atoms down to around a mK. To successfully load the atoms in the optical lattice, we have to cool the atoms further to beyond 50 μK. This is done by exciting the weak transition at 556 nm. The atoms that are transferred into the post-cooling stage are cooled down to a few tens of μK. The atoms are then ready to be loaded into the optical lattice at the magic wavelength. The amplified laser light at 760 nm inside the 1-D intra-vacuum cavity results in a lattice trapping potential of approximately 50 μK. A transfer efficiency, from the MOT into the optical lattice, of more than 25% was measured. The spectroscopy on the clock transition was done for 171Yb. A step-by-step mechanism was adopted, starting by exciting the forbidden transition at 578 nm inside the post-cooling stage MOT, by using the ”chopped-MOT” method. The 300 kHz Doppler-broadened line is then narrowed down to 3 kHz by switching on the light at 760 nm, while keeping the MOT on. The so-called ”chopped-lattice” technique helped suppress the Doppler-broadening; however the other effects due to the light and the magnetic fields of the MOT were still present. By switching off the MOT’s light and magnetic fields, the Yb atoms are completely trapped in the optical lattice. As a result, the FWHM of the spectroscopy line was reduced by a factor of 10.

•Jan 1, 2016•0 citations

Realization of the Compact Magneto-Optical Trap Based on Single Laser with Frequency Modulation

Shuning Bao, Bin Wu, Pengfei Cao +9 more

In cold atom physics, the complexity of traditional magneto-optical trap system limits the use of their associated instruments for field applications in atomic physics, such as gravity mapping, space navigation and deep space exploration. This study introduces a novel compact MOT design that addresses these issues by simplifying the structure and reducing the size. The height of the unit is 0.7 m, the volume is 6.3×10−2m3 and the mass is 11.32 kg. The new design utilizes a single laser to generate the two different frequencies needed for laser cooling by internally splitting the beam, shifting the frequency and then combining them, effectively controlling both the cooling and repumping beams. The compact vacuum chamber optical path, in conjunction with the magnetic field, facilitates the capture of 87Rb atoms in an ultra-high vacuum environment. Experimental results demonstrate an atom loading rate of up to 1.79×10787Rb atoms per second, confirming the system’s effectiveness in capturing and cooling 87Rb atoms. This design provides a flexible and portable solution, offering valuable insights for the advancement of compact MOT and its applications in cold atom physics.

Photonics•Jan 23, 2025•0 citations

Trapping and cooling of atoms

C. J. Pethick, H. Smith

The advent of the laser opened the way to the development of powerful new methods for manipulating and cooling atoms which were exploited in the realization of Bose–Einstein condensation in alkali atom vapours. To set the stage we describe a typical experiment, which is shown schematically in Fig. 4.1. A beam of sodium atoms emerges from an oven at a temperature of about 600 K, corresponding to a speed of about 800 m s –1 , and is then passed through a so-called Zeeman slower, in which the velocity of the atoms is reduced to about 30 m s –1 , corresponding to a temperature of about 1 K. In the Zeeman slower, a laser beam propagates in the direction opposite that of the atomic beam, and the radiation force produced by absorption of photons retards the atoms. Due to the Doppler effect, the frequency of the atomic transition in the laboratory frame is not generally constant, since the atomic velocity varies. However, by applying an inhomogeneous magnetic field designed so that the Doppler and Zeeman effects cancel, the frequency of the transition in the rest frame of the atom may be held fixed. On emerging from the Zeeman slower the atoms are slow enough to be captured by a magneto-optical trap (MOT), where they are further cooled by interactions with laser light to temperatures of order 100 μK. Another way of compensating for the changing Doppler shift is to increase the laser frequency in time, which is referred to as ‘chirping’. In other experiments the MOT is filled by transferring atoms from a second MOT where atoms are captured directly from the vapour.

Cambridge University Press eBooks•Nov 29, 2001•0 citations

Towards a strontium based stationary optical lattice clock

Qasim Hassan Ubaid

Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.

•Jul 20, 2020•0 citations
The compactness and robustness of the vacuum setup are the major limitations to develop transportable and space-borne optical clocks. The first step in the engineering challenge is to reduce volume and weight with respect to a stationary system. In this paper, we present the realization of a miniaturized vacuum system by building two anti-Helmholtz coils inside the vacuum magneto-optical-trap (MOT) chamber. The built-in coils are specially designed to minimize the distance between the coils, and in this way it is possible to reduce the current needed to realize a typical magnetic gradient of 40 Gs/cm required for blue MOT. When the MOT coil current is 2 A, an axial magnetic field gradient of 43 Gs/cm is obtained in the center of the MOT, which is enough for the first stage Doppler cooling. This novel design allows us to reduce size, weight and power consumption with respect to a traditional laser cooling apparatus, and simultaneously avoid complicating the water cooling equipment. Our vacuum system has a size of 60 cm×20 cm×15 cm, about 1/10 of the original system in the laboratory. In addition, the circularly polarized Zeeman slowing laser is sent to counter propagating atomic beam, and atoms at a few hundred meters per second are now routinely slowed down to velocities of tens of meters per second. As a result, about 16.4% of the atoms are actually trapped into the blue MOT. The final temperature of the blue MOT is approximately 10.6 mK, and the internal diameter is 1.5 mm by observing the expansion of the atoms from the MOT. The populations of cold atoms finally trapped in the MOT are 1.6×106 of 88Sr and 1.5×105 of 87Sr. The 1S0 → 1P1 transition used for the blue MOT is not perfectly closed due to the decay channel of the 5p1P1 → 4d1D2, and a part of atoms are stored in the 3P2 and 3P0 states. To prevent the atoms from losing, 707 and 679 nm repumping lasers are employed to recycle these atoms in the 3P1 state, and then the atoms decay to the ground state 1S0. Now the typical number of loaded atoms dramatically increases by 5 times compared with before. The slowing efficiency of Zeeman slower is also optimized for the operation with deceleration related to the parameter of magnet length, which uses more effectively available magnetic field distribution, in contrast to the usual constant deceleration mode. Our future work will focus on constructing a Zeeman slower combined with permanent magnets or an electric magnet for better tuning of the magnetic field.
We have developed a compact vacuum system for laser cooling and spectroscopy of neutral thulium atoms. Compactness is achieved by obviating a classical Zeeman slower section and placing an atomic oven close to a magneto-optical trap (MOT), specifically at the distance of 11 cm. In this configuration, we significantly gained in solid angle of an atomic beam, which is affected by MOT laser beams, and reached 1 million atoms loaded directly in the MOT with only 15 mW of MOT cooling beams net power. By exploiting Zeeman-like deceleration of atoms with an additional laser beam and tailoring the MOT magnetic field gradient with a small magnetic coil, we demonstrated trapping of up to 13 million atoms. These results show great perspective of the developed setup for realizing a compact high-performance optical atomic clock based on thulium atoms.
We report on building of a compact vacuum chamber for spectroscopy of ultracold thulium and trapping of up to 13 million atoms. Compactness is achieved by obviating a classical Zeeman slower section and placing an atomic oven close to a magneto-optical trap (MOT), specifically at the distance of 11 cm. In this configuration, we significantly gained in solid angle of an atomic beam, which is affected by MOT laser beams, and reached 1 million atoms loaded directly in the MOT. By exploiting Zeeman-like deceleration of atoms with an additional laser beam, we increased the number of trapped atoms to 6 million. Then we gained an extra factor of 2 by tailoring the MOT magnetic field gradient with an additional small magnetic coil. Demonstrated results show great perspective of the developed setup for realizing a compact high-performance optical atomic clock based on thulium atoms.
In this thesis, a transportable setup of an Yb atomic source for a lattice optical clock is built and characterized. All three laser setups for cooling and trapping the Yb atoms, together with the vacuum system, are contained on a transportable optical table. The preparation of the atomic sample before doing spectroscopy on the clock transition starts by slowing the atoms in the Zeeman slower. This is followed by trapping the atoms in the pre-cooling and the post-cooling MOTs, before loading the atoms into the optical lattice. Slowing and pre-cooling the atoms is done using the strong transition at 399 nm. This cools the atoms down to around a mK. To successfully load the atoms in the optical lattice, we have to cool the atoms further to beyond 50 μK. This is done by exciting the weak transition at 556 nm. The atoms that are transferred into the post-cooling stage are cooled down to a few tens of μK. The atoms are then ready to be loaded into the optical lattice at the magic wavelength. The amplified laser light at 760 nm inside the 1-D intra-vacuum cavity results in a lattice trapping potential of approximately 50 μK. A transfer efficiency, from the MOT into the optical lattice, of more than 25% was measured. The spectroscopy on the clock transition was done for 171Yb. A step-by-step mechanism was adopted, starting by exciting the forbidden transition at 578 nm inside the post-cooling stage MOT, by using the ”chopped-MOT” method. The 300 kHz Doppler-broadened line is then narrowed down to 3 kHz by switching on the light at 760 nm, while keeping the MOT on. The so-called ”chopped-lattice” technique helped suppress the Doppler-broadening; however the other effects due to the light and the magnetic fields of the MOT were still present. By switching off the MOT’s light and magnetic fields, the Yb atoms are completely trapped in the optical lattice. As a result, the FWHM of the spectroscopy line was reduced by a factor of 10.
In cold atom physics, the complexity of traditional magneto-optical trap system limits the use of their associated instruments for field applications in atomic physics, such as gravity mapping, space navigation and deep space exploration. This study introduces a novel compact MOT design that addresses these issues by simplifying the structure and reducing the size. The height of the unit is 0.7 m, the volume is 6.3×10−2m3 and the mass is 11.32 kg. The new design utilizes a single laser to generate the two different frequencies needed for laser cooling by internally splitting the beam, shifting the frequency and then combining them, effectively controlling both the cooling and repumping beams. The compact vacuum chamber optical path, in conjunction with the magnetic field, facilitates the capture of 87Rb atoms in an ultra-high vacuum environment. Experimental results demonstrate an atom loading rate of up to 1.79×10787Rb atoms per second, confirming the system’s effectiveness in capturing and cooling 87Rb atoms. This design provides a flexible and portable solution, offering valuable insights for the advancement of compact MOT and its applications in cold atom physics.
The advent of the laser opened the way to the development of powerful new methods for manipulating and cooling atoms which were exploited in the realization of Bose–Einstein condensation in alkali atom vapours. To set the stage we describe a typical experiment, which is shown schematically in Fig. 4.1. A beam of sodium atoms emerges from an oven at a temperature of about 600 K, corresponding to a speed of about 800 m s –1 , and is then passed through a so-called Zeeman slower, in which the velocity of the atoms is reduced to about 30 m s –1 , corresponding to a temperature of about 1 K. In the Zeeman slower, a laser beam propagates in the direction opposite that of the atomic beam, and the radiation force produced by absorption of photons retards the atoms. Due to the Doppler effect, the frequency of the atomic transition in the laboratory frame is not generally constant, since the atomic velocity varies. However, by applying an inhomogeneous magnetic field designed so that the Doppler and Zeeman effects cancel, the frequency of the transition in the rest frame of the atom may be held fixed. On emerging from the Zeeman slower the atoms are slow enough to be captured by a magneto-optical trap (MOT), where they are further cooled by interactions with laser light to temperatures of order 100 μK. Another way of compensating for the changing Doppler shift is to increase the laser frequency in time, which is referred to as ‘chirping’. In other experiments the MOT is filled by transferring atoms from a second MOT where atoms are captured directly from the vapour.
Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.