Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

High precision readout of superconducting resonators, for analysis of slow noise processes

Jonathan Burnett

Published Jan 1, 2014• 1 citation
OpenAlex

Related papers

Slow noise processes in superconducting resonators

Y. Harada

The Japan Society of Applied Physics•Feb 13, 2013•0 citations

Slow noise processes in superconducting resonators

Jonathan Burnett, T. Lindström, M. Oxborrow +4 more

Slow noise processes, with characteristic timescales $\ensuremath{\sim}$1 s, have been studied in planar superconducting resonators. A frequency-locked loop is employed to track deviations of the resonator center frequency with high precision and bandwidth. Comparative measurements are made in varying microwave drive and temperature, and between bare resonators and those with an additional dielectric layer. All resonators are found to exhibit flicker frequency noise which increases with decreasing microwave drive. We also show that an increase in temperature results in a saturation of flicker noise in resonators with an additional dielectric layer, while bare resonators stop exhibiting flicker noise, instead showing a random frequency walk process.

arXiv:1210.2351•Physical Review B•Apr 5, 2013•28 citations

Precise Frequency Measurements Using a Superconducting Cavity Stabilized Oscillator

D. M. Strayer, N.-C. Yeh, Wencai Jiang +2 more

Many physics experiments call on improved resolution to better define the experimental results, thus improving tests of theories. Modern microwave technology combined with high-Q resonators can achieve frequency readout and control with resolutions up to a part in 10(exp 18). When the physical quantity in question in the experiment can be converted to a frequency or a change in frequency, a high-stability microwave oscillator can be applied to obtain state-of-the-art precision. In this work we describe the overall physical concepts and the required experimental procedures for optimizing a high-resolution frequency measurement system that employs a high-Q superconducting microwave cavity and a low-noise frequency synthesizer. The basic approach is to resolve the resonant frequencies of a high-Q (Q > 10(exp 10)) cavity to extremely high precision (one part in 10(exp 17)- 10(exp 18)). Techniques for locking the synthesizer frequency to a resonant frequency of the superconducting cavity to form an ultra-stable oscillator are described. We have recently set up an ultra-high-vacuum high-temperature annealing system to process superconducting niobium cavities, and have been able to consistently achieve Q > 10(exp 9). We have integrated high-Q superconducting cavities with a low-noise microwave synthesizer in a phase-locked-loop to verify the frequency stability of the system. Effects that disturb the cavity resonant frequency (such as the temperature fluctuations and mechanical vibrations) and methods to mitigate those effects are also considered. Applicability of these techniques to experiments will be discussed, and our latest experimental progress in achieving high-resolution frequency measurements using the superconducting-cavity-stabilized-oscillator will be presented.

•Jan 1, 1999•0 citations

Efficient Measurement of Superconducting Resonators

S. Sendelbach, M. J. A. Stoutimore, Josh Strong +3 more

Bulletin of the American Physical Society•Mar 5, 2014•0 citations

Noise from Two-Level Systems in Superconducting Resonators

C. Neill, R. Barends, Y. Chen +13 more

Bulletin of the American Physical Society•Mar 18, 2013•0 citations

Accurate Real-Time Monitoring of Quality Factor and Center Frequency of Superconducting Resonators

Sebastian E. de Graaf, Andrey V. Danilov, Sergey Kubatkin

In this paper, we track both center frequency and quality factor of a superconducting microwave resonator with very high precision using a modified Pound-Drever-Hall frequency locking scheme. The quality factor measurements can be done with high enough bandwidth to study different processes in a superconducting resonator in real time. With this added functionality, the frequency readout remains unaffected, with typical accuracy around 10-30 Hz/√(Hz), whereas the cavity loss rate can be determined to within 0.1% on a millisecond time scale (34 dB/√(Hz)). As we demonstrate, this can be particularly useful for electron spin resonance measurements, where we achieve a minimum number of detectable spins coupled to the resonator N = 5 ·105spins/√(Hz), based on quality factor measurements. It also enables the study of fast dynamic processes, for example, vortex dynamics, in these devices on a short time scale.

IEEE Transactions on Applied Superconductivity•Apr 9, 2014•8 citations
Slow noise processes, with characteristic timescales $\ensuremath{\sim}$1 s, have been studied in planar superconducting resonators. A frequency-locked loop is employed to track deviations of the resonator center frequency with high precision and bandwidth. Comparative measurements are made in varying microwave drive and temperature, and between bare resonators and those with an additional dielectric layer. All resonators are found to exhibit flicker frequency noise which increases with decreasing microwave drive. We also show that an increase in temperature results in a saturation of flicker noise in resonators with an additional dielectric layer, while bare resonators stop exhibiting flicker noise, instead showing a random frequency walk process.
Many physics experiments call on improved resolution to better define the experimental results, thus improving tests of theories. Modern microwave technology combined with high-Q resonators can achieve frequency readout and control with resolutions up to a part in 10(exp 18). When the physical quantity in question in the experiment can be converted to a frequency or a change in frequency, a high-stability microwave oscillator can be applied to obtain state-of-the-art precision. In this work we describe the overall physical concepts and the required experimental procedures for optimizing a high-resolution frequency measurement system that employs a high-Q superconducting microwave cavity and a low-noise frequency synthesizer. The basic approach is to resolve the resonant frequencies of a high-Q (Q > 10(exp 10)) cavity to extremely high precision (one part in 10(exp 17)- 10(exp 18)). Techniques for locking the synthesizer frequency to a resonant frequency of the superconducting cavity to form an ultra-stable oscillator are described. We have recently set up an ultra-high-vacuum high-temperature annealing system to process superconducting niobium cavities, and have been able to consistently achieve Q > 10(exp 9). We have integrated high-Q superconducting cavities with a low-noise microwave synthesizer in a phase-locked-loop to verify the frequency stability of the system. Effects that disturb the cavity resonant frequency (such as the temperature fluctuations and mechanical vibrations) and methods to mitigate those effects are also considered. Applicability of these techniques to experiments will be discussed, and our latest experimental progress in achieving high-resolution frequency measurements using the superconducting-cavity-stabilized-oscillator will be presented.
In this paper, we track both center frequency and quality factor of a superconducting microwave resonator with very high precision using a modified Pound-Drever-Hall frequency locking scheme. The quality factor measurements can be done with high enough bandwidth to study different processes in a superconducting resonator in real time. With this added functionality, the frequency readout remains unaffected, with typical accuracy around 10-30 Hz/√(Hz), whereas the cavity loss rate can be determined to within 0.1% on a millisecond time scale (34 dB/√(Hz)). As we demonstrate, this can be particularly useful for electron spin resonance measurements, where we achieve a minimum number of detectable spins coupled to the resonator N = 5 ·105spins/√(Hz), based on quality factor measurements. It also enables the study of fast dynamic processes, for example, vortex dynamics, in these devices on a short time scale.