We present designs for the augmentation ``mirror'' pulses of large-momentum-transfer atom interferometers that maintain their fidelity as the wave-packet momentum difference is increased. These biselective pulses, tailored using optimal control methods to the evolving bimodal momentum distribution, should allow greater interferometer areas and hence increased inertial measurement sensitivity, without requiring elevated Rabi frequencies or extended frequency chirps. Using an experimentally validated model, we have simulated the application of our pulse designs to large-momentum-transfer atom interferometry using stimulated Raman transitions in a laser-cooled atomic sample of
85Rb at 1 $\ensuremath{\mu}\mathrm{K}$. After the wave packets have separated by 42 photon recoil momenta, our pulses maintain a fringe contrast of 90%, whereas, for adiabatic rapid passage and conventional $\ensuremath{\pi}$ pulses, the contrast is less than 10%. Furthermore, we show how these pulses may be adapted to be robust to laser intensity variations between pulses and to suppress the detrimental off-resonant excitation that limits other broadband pulse schemes.
Quantum sensors based upon atom interferometry typically rely on radio-frequency or optical pulses to coherently manipulate atomic states and make precise measurements of inertial and gravitational effects. An advantage of these sensors over their classical counterparts is often said to be that their measurement scale factor is precisely known and highly stable. However, in practice the finite pulse duration makes the sensor scale factor dependent upon the pulse shape and sensitive to variations in control field intensity, frequency, and atomic velocity. Here, we explore the concept of a temporal pulse origin in atom interferometry, where the inertial phase response of any pulse can be parameterized using a single point in time. We show that the temporal origin permits a simple determination of the measurement scale factor and its stability against environmental perturbations. Moreover, the temporal origin can be treated as a tunable parameter in the design of tailored sequences of shaped pulses to enhance scale factor stability and minimize systematic errors. We demonstrate through simulations that this approach to pulse design can reduce overall sequence durations while increasing robustness to realistic fluctuations in control field amplitude. Our results show that the temporal pulse origin explains a broad class of systematic errors in existing devices and enables the design of short, robust pulses which we expect will improve the performance of current and next-generation interferometric quantum sensors.