EPJ Web of Conferences

The xenon hyperpolarization by alexandrite laser spin exchange optical pumping

A. G. Putilov, А. А. Антипов, Alexandr Shepelev

Published Oct 25, 2019• 3 citations
Publisher

Abstract

This paper shows the possibility of the use of a solid-state alexandrite laser as a radiation source for the method of spin-exchange optical pumping of noble gases (xenon, krypton). The use of dispersive optical elements in the laser cavity will allows the adjusting of the radiation wavelength exactly in the rubidium spectral absorption lines 794.7 nm and 780 nm. To obtain a hyperpolarized state of noble gases, it is necessary to excite rubidium atoms for further spin-exchange process with the noble gas nuclei. This fact will allow the increasing of the magnetic resonance imaging contrast in the field of diagnosis of respiratory organs diseases.

DOI
10.1051/epjconf/201922003026

Related papers

Production of Hyperpolarized 129Xe Using Spin Exchange Optical Pumping

Vladimir Vladimirovich Kavtanyuk, Wooyoung Kim, Yu Ando +3 more

We present a constructed setup for polarizing 129 Xe noble gas. Hyperpolarized 129 Xe has been obtained via spin exchange with an optically pumped rubidium vapor. Optical pumping is based on polarizing the valence electron of rubidium by the resonant absorption of a circularly polarized laser light. The magnetic field of 30 G was used for obtaining 129 Xe polarization. The apparatus for detecting polarization is a nuclear magnetic resonance spectrometer. The highest 129 Xe polarization of 54% has been obtained using 60 W circularly polarized laser light with wavelength of 794.7 nm. The measured longitudinal relaxation time of the hyperpolarized 129 Xe was 72.3 minutes.

Journal of the Korean Physical Society•Nov 1, 2018•1 citation

Optical pumping of rubidium isotopes by Cr3+:BeAl2O4 laser radiation

Alexei A. Antipov, A. G. Putilov, A. E. Shepelev

We consider the use of a Cr3+:BeAl2O4 laser in free-running operating as a source of emission for optical pumping rubidium alkali metal vapors. The use of dispersive elements in the composition of the laser cavity makes it possible to smoothly tune lasing wavelength and to realize generation at wavelengths corresponding to the D1 and D2 lines of the 85Rb and 87Rb isotopes. Optical pumping of rubidium isotopes by laser emission with wavelengths of 795 and 780 nm, respectively, is experimentally implemented, and their fluorescence is demonstrated. The question of using a wavelength-tunable laser in the method of spin-exchange optical pumping of noble gases is discussed.

Известия Российской академии наук Серия физическая•Nov 1, 2023•0 citations

High-efficiency laser-pumping system for magnetic resonance imaging

Marziale Milani, Guido Baroni, Lorenzo Ferraro +3 more

Recently the demand for hyperpolarized noble gases is arising to improve NMR spectroscopy resolution for imaging. Hyperpolarization of noble gases is achieved by spin- exchange with alkali metal. atoms that undergo optical pumping by circularly polarized radiation. Optical pumping is usually achieved by high power semiconductor lasers. These sources have a bandwidth very large when compared with the transition bandwidth of the optically active species. This has two serious consequences: (i) the request of high power lasers, (ii) the losses that the unemployed energy delivered to the Rb vapor can provide in the efficiency of the energy transfer. Object of our investigation will be the comparison of two experimental set ups for optical pumping of Rb vapor where pumping is given in one case by a dye laser pumped by a UV nitrogen laser built in our laboratory according to the Blumlein scheme and in the other case by a semiconductor laser. Major elements that will be discussed are (1) the role of stimulated emission of Rb vapor to increase the pumping efficiency, (2) the fate of resonant photons that are emitted during Rb decays, (3) the role of applied magnetic fields in the efficiency of pumping processes.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 3, 2000•1 citation

Generation and detection of hyperpolarized xenon

Zdeněk Buchta, Jan Rychnovský, Zenon Starčuk +1 more

We present the experimental results of generation and of detection of hyperpolarized xenon obtained by 4.7 T, 200 MHz magnetic resonance (MR) system. Xenon 129 was hyperpolarized by the spin-exchange with Rubidium pumped first by Ti:Sa laser and also by extended cavity laser system based on a high-power laser diode optimized for maximum efficiency of the optical pumping process. The application of the arrangement with semiconductor laser system is oriented medicine, especially to continuous production of hyperpolarized Xenon (HpXe) which serves as an contrast media in MR imaging systems.

IEEE AFRICON•Sep 1, 2007•0 citations

Optical Pumping of Rubidium Isotopes with the Radiation of a Cr3+:BeAl2O4 Laser

Alexei A. Antipov, A. G. Putilov, A. E. Shepelev

Abstract The authors consider the use of a Cr3+:BeAl2O4 laser operating in the mode of free generation as a source of radiation for the optical pumping of vapors of rubidium alkali metal. The use of dispersive elements in the composition of the laser resonator allows smooth tuning of the radiation and generation at wavelengths corresponding to lines D1 and D2 of isotopes 85Rb and 87Rb. The optical pumping of rubidium isotopes using laser radiation with wavelengths of 795 and 780 nm, respectively, is performed experimentally. The fluorescence of the isotopes is demonstrated. The use of tunable wavelength laser generation in the spin-exchange optical pumping of noble gases is discussed.

Bulletin of the Russian Academy of Sciences Physics•Nov 1, 2023•2 citations

Hyperpolarised helium and xenon production and applications to imaging and materials analysis

Cavin Talbot

In this thesis I discuss experiments to create hyperpolarised noble gases. In particular, we have constructed an apparatus to hyperpolarise helium and xenon gases and used these resources to image the lungs of living rats and probe the physical properties of mesoporous solids. The apparatus uses a line-width narrowed laser diode array to optically pump rubidium vapour which then polarises the noble gases through spin-exchange collisions. We have also developed techniques to optimise both the amount and rate of polarisation. Using these techniques, we have shown that the apparatus can produce hyperpolarised helium in 350mL volumes with a polarisation of up to 25%. It can also produce hyperpolarised xenon in a continuous flow which results in 10% polarisation of the xenon at a rate of 1018 polarised atoms per minute with only four watts of laser light incident on the cell. The optical feedback system for laser diode arrays was improved to correct for the divergence of the beam caused by curvature in the array of diode elements. This curvature of the array is an artifact of the manufacturing process and causes an increase in the full width half maximum (FWHM) achievable for the spectral profile of the array when using optical feedback to spectrally narrow the laser diode array. The optical feedback allowed the tenfold narrowing of the laser line-width with the additional treatment of the “smile” giving a further 30% improvement. The feedback allowed more efficient absorption of the light at much lower pressures. A probe was designed and constructed to measure the polarisation of the rubidium atoms in the two possible levels of the 5S ground state. This probe enabled the rapid optimisation of the polarisation of the rubidium atoms which in turn led to the best polarisation rates measured for the equipment. We have successfully used the hyperpolarised helium from our apparatus to produce high resolution images of lungs of rats that have been kept alive for the duration of the experiments on a ventilator system. These images far surpass the quality of lung images from standard MRI techniques. We also used the hyperpolarised xenon gas to measure pore sizes in mesoporous solids by detecting the shift in the xenon resonance frequency caused by the interaction with the material, and we investigated the effect on the frequency shift of water absorbed in the material. The pore sizes of the materials ranged from 2.5 to 16 nm.

•Aug 1, 2008•0 citations
This paper shows the possibility of the use of a solid-state alexandrite laser as a radiation source for the method of spin-exchange optical pumping of noble gases (xenon, krypton). The use of dispersive optical elements in the laser cavity will allows the adjusting of the radiation wavelength exactly in the rubidium spectral absorption lines 794.7 nm and 780 nm. To obtain a hyperpolarized state of noble gases, it is necessary to excite rubidium atoms for further spin-exchange process with the noble gas nuclei. This fact will allow the increasing of the magnetic resonance imaging contrast in the field of diagnosis of respiratory organs diseases.
We present a constructed setup for polarizing 129 Xe noble gas. Hyperpolarized 129 Xe has been obtained via spin exchange with an optically pumped rubidium vapor. Optical pumping is based on polarizing the valence electron of rubidium by the resonant absorption of a circularly polarized laser light. The magnetic field of 30 G was used for obtaining 129 Xe polarization. The apparatus for detecting polarization is a nuclear magnetic resonance spectrometer. The highest 129 Xe polarization of 54% has been obtained using 60 W circularly polarized laser light with wavelength of 794.7 nm. The measured longitudinal relaxation time of the hyperpolarized 129 Xe was 72.3 minutes.
We consider the use of a Cr3+:BeAl2O4 laser in free-running operating as a source of emission for optical pumping rubidium alkali metal vapors. The use of dispersive elements in the composition of the laser cavity makes it possible to smoothly tune lasing wavelength and to realize generation at wavelengths corresponding to the D1 and D2 lines of the 85Rb and 87Rb isotopes. Optical pumping of rubidium isotopes by laser emission with wavelengths of 795 and 780 nm, respectively, is experimentally implemented, and their fluorescence is demonstrated. The question of using a wavelength-tunable laser in the method of spin-exchange optical pumping of noble gases is discussed.
Recently the demand for hyperpolarized noble gases is arising to improve NMR spectroscopy resolution for imaging. Hyperpolarization of noble gases is achieved by spin- exchange with alkali metal. atoms that undergo optical pumping by circularly polarized radiation. Optical pumping is usually achieved by high power semiconductor lasers. These sources have a bandwidth very large when compared with the transition bandwidth of the optically active species. This has two serious consequences: (i) the request of high power lasers, (ii) the losses that the unemployed energy delivered to the Rb vapor can provide in the efficiency of the energy transfer. Object of our investigation will be the comparison of two experimental set ups for optical pumping of Rb vapor where pumping is given in one case by a dye laser pumped by a UV nitrogen laser built in our laboratory according to the Blumlein scheme and in the other case by a semiconductor laser. Major elements that will be discussed are (1) the role of stimulated emission of Rb vapor to increase the pumping efficiency, (2) the fate of resonant photons that are emitted during Rb decays, (3) the role of applied magnetic fields in the efficiency of pumping processes.
We present the experimental results of generation and of detection of hyperpolarized xenon obtained by 4.7 T, 200 MHz magnetic resonance (MR) system. Xenon 129 was hyperpolarized by the spin-exchange with Rubidium pumped first by Ti:Sa laser and also by extended cavity laser system based on a high-power laser diode optimized for maximum efficiency of the optical pumping process. The application of the arrangement with semiconductor laser system is oriented medicine, especially to continuous production of hyperpolarized Xenon (HpXe) which serves as an contrast media in MR imaging systems.
Abstract The authors consider the use of a Cr3+:BeAl2O4 laser operating in the mode of free generation as a source of radiation for the optical pumping of vapors of rubidium alkali metal. The use of dispersive elements in the composition of the laser resonator allows smooth tuning of the radiation and generation at wavelengths corresponding to lines D1 and D2 of isotopes 85Rb and 87Rb. The optical pumping of rubidium isotopes using laser radiation with wavelengths of 795 and 780 nm, respectively, is performed experimentally. The fluorescence of the isotopes is demonstrated. The use of tunable wavelength laser generation in the spin-exchange optical pumping of noble gases is discussed.
In this thesis I discuss experiments to create hyperpolarised noble gases. In particular, we have constructed an apparatus to hyperpolarise helium and xenon gases and used these resources to image the lungs of living rats and probe the physical properties of mesoporous solids. The apparatus uses a line-width narrowed laser diode array to optically pump rubidium vapour which then polarises the noble gases through spin-exchange collisions. We have also developed techniques to optimise both the amount and rate of polarisation. Using these techniques, we have shown that the apparatus can produce hyperpolarised helium in 350mL volumes with a polarisation of up to 25%. It can also produce hyperpolarised xenon in a continuous flow which results in 10% polarisation of the xenon at a rate of 1018 polarised atoms per minute with only four watts of laser light incident on the cell. The optical feedback system for laser diode arrays was improved to correct for the divergence of the beam caused by curvature in the array of diode elements. This curvature of the array is an artifact of the manufacturing process and causes an increase in the full width half maximum (FWHM) achievable for the spectral profile of the array when using optical feedback to spectrally narrow the laser diode array. The optical feedback allowed the tenfold narrowing of the laser line-width with the additional treatment of the “smile” giving a further 30% improvement. The feedback allowed more efficient absorption of the light at much lower pressures. A probe was designed and constructed to measure the polarisation of the rubidium atoms in the two possible levels of the 5S ground state. This probe enabled the rapid optimisation of the polarisation of the rubidium atoms which in turn led to the best polarisation rates measured for the equipment. We have successfully used the hyperpolarised helium from our apparatus to produce high resolution images of lungs of rats that have been kept alive for the duration of the experiments on a ventilator system. These images far surpass the quality of lung images from standard MRI techniques. We also used the hyperpolarised xenon gas to measure pore sizes in mesoporous solids by detecting the shift in the xenon resonance frequency caused by the interaction with the material, and we investigated the effect on the frequency shift of water absorbed in the material. The pore sizes of the materials ranged from 2.5 to 16 nm.