Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Pulsed entanglement measured by parametric amplifier assisted homodyne detection

Jiamin Li, Yuhong Liu, Nan Huo, Liang Cui, Chang Qing Feng, Z. Y. Ou, Xiaoying Li

Published Oct 8, 2019• 19 citations
Publisher

Abstract

Balanced homodyne detection relies on a beam splitter to superpose the weak signal input and strong local oscillator. However, recent investigation shows that a high gain phase sensitive amplifier (PSA) can be viewed as homodyne detector, in which the strong pump of PSA serves as the local oscillator [1]. Here, we analyze a new method of measuring the continuous variable entanglement by assisting a balanced homodyne detector with the PSA and implement it experimentally. Before measuring quadrature amplitude with the balanced homodyne detectors, two entangled fields generated from a pulse pumped fiber optical parametric amplifier are simultaneously coupled into the PSA. We find that the normalized noise for both the difference and sum of the quadrature amplitudes of the two entangled fields fall below the shot noise limit by about 4.6 dB, which is the record degree of entanglement measured in optical fiber systems. The experimental results illustrate that the advantages of the new measurement method include but not limit to tolerance to detection loss and characterizing entanglement with only one homodyne detector. The influence of mode-mismatching due to multi-mode property of entanglement on the measured noise reduction can also be greatly mitigated, indicating the new method is advantageous over the traditional measurement in multi-mode case.

DOI
10.1364/oe.27.030552

Related papers

Measuring continuous-variable quantum entanglement with parametric-amplifier-assisted homodyne detection

Jiamin Li, Yuhong Liu, Nan Huo +4 more

The traditional method for measuring Einstein-Podolsky-Rosen-type continuous-variable quantum entanglement relies on balanced homodyne detections, which are sensitive to vacuum quantum noise coupled in through losses due to various factors such as detector quantum efficiency and mode mismatching between the detected field and the local oscillator. In this paper, we propose and analyze a measurement method, which is realized by assisting the balanced homodyne detections with a high-gain phase-sensitive parametric amplifier. The employment of the phase-sensitive amplifier helps us to tackle the vacuum quantum noise originating from detection losses. Moreover, because the high-gain phase-sensitive amplifier can couple two fields of different types, the proposed scheme can be used to reveal quantum entanglement between two fields of different types by using only one balanced homodyne detection. Furthermore, detailed analysis shows that in the multimode case, the proposed scheme is also advantageous over the traditional method. Such a measurement method should find wide applications in quantum information and quantum metrology involving measurement of continuous variables.

arXiv:1808.10258•Physical Review A•May 1, 2020•18 citations

Complete temporal mode analysis in pulse-pumped fiber-optical parametric amplifier for continuous variable entanglement generation

Xueshi Guo, Nannan Liu, Xiaoying Li +1 more

Mode matching plays an important role in measuring the continuous variable entanglement. For the signal and idler twin beams generated by a pulse pumped fiber optical parametric amplifier (FOPA), the spatial mode matching is automatically achieved in single mode fiber, but the temporal mode property is complicated because it is highly sensitive to the dispersion and the gain of the FOPA. We study the temporal mode structure and derive the input-output relation for each temporal mode of signal and idler beams after decomposing the joint spectral function of twin beams with the singular-value decomposition method. We analyze the measurement of the quadrature-amplitude entanglement, and find mode matching between the multi-mode twin beams and the local oscillators of homodyne detection systems is crucial to achieve a high degree of entanglement. The results show that the noise contributed by the temporal modes nonorthogonal to local oscillator may be much larger than the vacuum noise, so the mode mis-match can not be accounted for by merely introducing an effective loss. Our study will be useful for developing a source of high quality continuous variable entanglement by using the FOPA.

Optics Express•Nov 2, 2015•34 citations

Pulsed entanglement measured by parametric amplifier assisted homodyne detection

Yuhong Liu, Jiamin Li, Nan Huo +4 more

Using the detection system consisting of a phase sensitive amplifier and standard homodyne detectors, we experimentally demonstrate that the influence of detection loss and multi-mode property of entangled fields can be greatly mitigated.

Frontiers in Optics•Jan 1, 2019•2 citations

Complete temporal mode analysis in pulse-pumped fiber-optical parametric amplifier for continuous variable entanglement generation

Xueshi Guo, Nannan Liu, Xiaoying Li +1 more

Mode matching plays an important role in measuring the continuous variable entanglement. For the signal and idler twin beams generated by a pulse pumped fiber optical parametric amplifier (FOPA), the spatial mode matching is automatically achieved in single mode fiber, but the temporal mode property is complicated because it is highly sensitive to the dispersion and the gain of the FOPA. We study the temporal mode structure and derive the input-output relation for each temporal mode of signal and idler beams after decomposing the joint spectral function of twin beams with the singular-value decomposition method. We analyze the measurement of the quadrature-amplitude entanglement, and find mode matching between the multi-mode twin beams and the local oscillators of homodyne detection systems is crucial to achieve a high degree of entanglement. The results show that the noise contributed by the temporal modes nonorthogonal to local oscillator may be much larger than the vacuum noise, so the mode mis-match can not be accounted for by merely introducing an effective loss. Our study will be useful for developing a source of high quality continuous variable entanglement by using the FOPA.

Author eBooks•Jan 1, 2015•0 citations

Generation of continuous variable quantum entanglement using a fiber optical parametric amplifier

Xueshi Guo, Nannan Liu, Yuhong Liu +2 more

We demonstrate the experimental generation of quadrature amplitude entanglement in the 1550 nm band by using a fiber optical parametric amplifier. The measured noise variances of the difference and sum of the quadrature amplitudes of the pulsed signal and idler twin beams fall below the shot noise limit by about 1 and 0.8 dB (4.2 and 3.6 dB after the correction for efficiency), respectively, showing that the inseparability criterion of Einstein-Podolsky-Rosen entanglement I<2 is satisfied. Our investigation reveals that the quality of the measured entanglement can be further improved by increasing the transmission efficiency of the twin beams and by optimizing the temporal mode matching of the two sets of homodyne detection systems.

Optics Letters•Feb 1, 2016•25 citations

Experimental generation of 6 dB continuous variable entanglement from a nondegenerate optical parametric amplifier

Yu Wang, Heng Shen, Xiaoli Jin +3 more

We experimentally demonstrated that the quantum correlations of amplitude and phase quadratures between signal and idler beams produced from a non-degenerate optical parametric amplifier (NOPA) can be significantly improved by using a mode cleaner in the pump field and reducing the phase fluctuations in phase locking systems. Based on the two technical improvements the quantum entanglement measured with a two-mode homodyne detector is enhanced from approximately 4 dB to approximately 6 dB below the quantum noise limit using the same NOPA and nonlinear crystal.

arXiv:1003.2460•Optics Express•Mar 11, 2010•53 citations
Balanced homodyne detection relies on a beam splitter to superpose the weak signal input and strong local oscillator. However, recent investigation shows that a high gain phase sensitive amplifier (PSA) can be viewed as homodyne detector, in which the strong pump of PSA serves as the local oscillator [1]. Here, we analyze a new method of measuring the continuous variable entanglement by assisting a balanced homodyne detector with the PSA and implement it experimentally. Before measuring quadrature amplitude with the balanced homodyne detectors, two entangled fields generated from a pulse pumped fiber optical parametric amplifier are simultaneously coupled into the PSA. We find that the normalized noise for both the difference and sum of the quadrature amplitudes of the two entangled fields fall below the shot noise limit by about 4.6 dB, which is the record degree of entanglement measured in optical fiber systems. The experimental results illustrate that the advantages of the new measurement method include but not limit to tolerance to detection loss and characterizing entanglement with only one homodyne detector. The influence of mode-mismatching due to multi-mode property of entanglement on the measured noise reduction can also be greatly mitigated, indicating the new method is advantageous over the traditional measurement in multi-mode case.
The traditional method for measuring Einstein-Podolsky-Rosen-type continuous-variable quantum entanglement relies on balanced homodyne detections, which are sensitive to vacuum quantum noise coupled in through losses due to various factors such as detector quantum efficiency and mode mismatching between the detected field and the local oscillator. In this paper, we propose and analyze a measurement method, which is realized by assisting the balanced homodyne detections with a high-gain phase-sensitive parametric amplifier. The employment of the phase-sensitive amplifier helps us to tackle the vacuum quantum noise originating from detection losses. Moreover, because the high-gain phase-sensitive amplifier can couple two fields of different types, the proposed scheme can be used to reveal quantum entanglement between two fields of different types by using only one balanced homodyne detection. Furthermore, detailed analysis shows that in the multimode case, the proposed scheme is also advantageous over the traditional method. Such a measurement method should find wide applications in quantum information and quantum metrology involving measurement of continuous variables.
Mode matching plays an important role in measuring the continuous variable entanglement. For the signal and idler twin beams generated by a pulse pumped fiber optical parametric amplifier (FOPA), the spatial mode matching is automatically achieved in single mode fiber, but the temporal mode property is complicated because it is highly sensitive to the dispersion and the gain of the FOPA. We study the temporal mode structure and derive the input-output relation for each temporal mode of signal and idler beams after decomposing the joint spectral function of twin beams with the singular-value decomposition method. We analyze the measurement of the quadrature-amplitude entanglement, and find mode matching between the multi-mode twin beams and the local oscillators of homodyne detection systems is crucial to achieve a high degree of entanglement. The results show that the noise contributed by the temporal modes nonorthogonal to local oscillator may be much larger than the vacuum noise, so the mode mis-match can not be accounted for by merely introducing an effective loss. Our study will be useful for developing a source of high quality continuous variable entanglement by using the FOPA.
Mode matching plays an important role in measuring the continuous variable entanglement. For the signal and idler twin beams generated by a pulse pumped fiber optical parametric amplifier (FOPA), the spatial mode matching is automatically achieved in single mode fiber, but the temporal mode property is complicated because it is highly sensitive to the dispersion and the gain of the FOPA. We study the temporal mode structure and derive the input-output relation for each temporal mode of signal and idler beams after decomposing the joint spectral function of twin beams with the singular-value decomposition method. We analyze the measurement of the quadrature-amplitude entanglement, and find mode matching between the multi-mode twin beams and the local oscillators of homodyne detection systems is crucial to achieve a high degree of entanglement. The results show that the noise contributed by the temporal modes nonorthogonal to local oscillator may be much larger than the vacuum noise, so the mode mis-match can not be accounted for by merely introducing an effective loss. Our study will be useful for developing a source of high quality continuous variable entanglement by using the FOPA.
We demonstrate the experimental generation of quadrature amplitude entanglement in the 1550 nm band by using a fiber optical parametric amplifier. The measured noise variances of the difference and sum of the quadrature amplitudes of the pulsed signal and idler twin beams fall below the shot noise limit by about 1 and 0.8 dB (4.2 and 3.6 dB after the correction for efficiency), respectively, showing that the inseparability criterion of Einstein-Podolsky-Rosen entanglement I<2 is satisfied. Our investigation reveals that the quality of the measured entanglement can be further improved by increasing the transmission efficiency of the twin beams and by optimizing the temporal mode matching of the two sets of homodyne detection systems.
We experimentally demonstrated that the quantum correlations of amplitude and phase quadratures between signal and idler beams produced from a non-degenerate optical parametric amplifier (NOPA) can be significantly improved by using a mode cleaner in the pump field and reducing the phase fluctuations in phase locking systems. Based on the two technical improvements the quantum entanglement measured with a two-mode homodyne detector is enhanced from approximately 4 dB to approximately 6 dB below the quantum noise limit using the same NOPA and nonlinear crystal.