Frontiers in Optics

Pulsed entanglement measured by parametric amplifier assisted homodyne detection

Yuhong Liu, Jiamin Li, Nan Huo, Liang Cui, Chang Qing Feng, Z. Y. Ou, Xiaoying Li

Published Jan 1, 2019• 2 citations
Publisher

Abstract

Using the detection system consisting of a phase sensitive amplifier and standard homodyne detectors, we experimentally demonstrate that the influence of detection loss and multi-mode property of entangled fields can be greatly mitigated.
DOI
10.1364/fio.2019.jw3a.52

Related papers

Pulsed entanglement measured by parametric amplifier assisted homodyne detection

Jiamin Li, Yuhong Liu, Nan Huo +4 more

Balanced homodyne detection relies on a beam splitter to superpose the weak signal input and strong local oscillator. However, recent investigation shows that a high gain phase sensitive amplifier (PSA) can be viewed as homodyne detector, in which the strong pump of PSA serves as the local oscillator [1]. Here, we analyze a new method of measuring the continuous variable entanglement by assisting a balanced homodyne detector with the PSA and implement it experimentally. Before measuring quadrature amplitude with the balanced homodyne detectors, two entangled fields generated from a pulse pumped fiber optical parametric amplifier are simultaneously coupled into the PSA. We find that the normalized noise for both the difference and sum of the quadrature amplitudes of the two entangled fields fall below the shot noise limit by about 4.6 dB, which is the record degree of entanglement measured in optical fiber systems. The experimental results illustrate that the advantages of the new measurement method include but not limit to tolerance to detection loss and characterizing entanglement with only one homodyne detector. The influence of mode-mismatching due to multi-mode property of entanglement on the measured noise reduction can also be greatly mitigated, indicating the new method is advantageous over the traditional measurement in multi-mode case.

Optics Express•Oct 8, 2019•19 citations

Measuring continuous-variable quantum entanglement with parametric-amplifier-assisted homodyne detection

Jiamin Li, Yuhong Liu, Nan Huo +4 more

The traditional method for measuring Einstein-Podolsky-Rosen-type continuous-variable quantum entanglement relies on balanced homodyne detections, which are sensitive to vacuum quantum noise coupled in through losses due to various factors such as detector quantum efficiency and mode mismatching between the detected field and the local oscillator. In this paper, we propose and analyze a measurement method, which is realized by assisting the balanced homodyne detections with a high-gain phase-sensitive parametric amplifier. The employment of the phase-sensitive amplifier helps us to tackle the vacuum quantum noise originating from detection losses. Moreover, because the high-gain phase-sensitive amplifier can couple two fields of different types, the proposed scheme can be used to reveal quantum entanglement between two fields of different types by using only one balanced homodyne detection. Furthermore, detailed analysis shows that in the multimode case, the proposed scheme is also advantageous over the traditional method. Such a measurement method should find wide applications in quantum information and quantum metrology involving measurement of continuous variables.

arXiv:1808.10258•Physical Review A•May 1, 2020•18 citations

Loss-tolerant measurement of continuous-variable quantum entanglement with the aid of a high gain parametric amplifier

Jiamin Li, Yuhong Liu, Nan Huo +3 more

•Aug 30, 2018•0 citations

Sensitivity Evaluation of SU(1,1) Interferometers with Arbitrary Input Probe State and Homodyne Detections

Sonu Jana, Dhruv Baheti, Paul Grossiord +3 more

We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses. In this systematic review, both full SU(1,1) interferometers with two parametric amplifiers and the truncated interferometers with only one parametric amplifier are examined. We investigate scenarios involving both single-output ports and joint homodyne detection, and consider parametric amplifiers with equal gains or with a boosted gain second amplifier. Our analytical formulation provides physical insight and understanding of the improvements in the sensitivity, which are shown to originate from noise reduction and/or signal amplification, depending on the configurations and practical implementations. Surprisingly, the configuration with single-output mode detection and parametric amplifiers with equal gains exhibits the highest robustness to very high internal losses. We finally apply this framework to a ubiquitous $|α,0\rangle$ input two-mode coherent probe state. This approach permits the comparison of different strategies and the optimization of the interferometer performance in the presence of losses. In particular, we determine which amplification and detection configurations provide the best performance, depending on the level of losses. This exemplifies how this general analytical approach provides a powerful tool to design quantum-enhanced interferometers and achieve optimal sensitivity with selected probe states and homodyne detection.

quant-pharXiv:2605.22029•May 22, 2026•0 citations

Generation and detection of entangled light fields with negative Wigner functions

Alexei Ourjoumtsev, Aurélien Dantan, Rosa Tualle-Brouri +1 more

We experimentally demonstrate that the entanglement between Gaussian entangled states can be increased by non-Gaussian operations.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•0 citations

Reconstruction of a multimode entangled state using a two-photon phase-sensitive linear amplifier

Mashhood Ahmad, Shahid Qamar, Muhammad Suhail Zubairy

We propose a model for the measurement of an arbitrary multimode entangled state of the cavity field using two-photon correlated emission laser. We consider two cases: (a) The modes have different frequencies and are detected separately and (b) the modes consist of two orthogonal polarization states and are detected using a single balanced homodyne detector. The basic idea is to amplify the initial multimode state such that there is no-noise in the quadrature of interest and all the noise is fed into the conjugate quadrature component. The amplified noise-free quadrature is prepared in different phases and then corresponding quadrature distribution is measured. The Wigner function of the initial multimode entangled state is then reconstructed by using inverse Radon transformation. This scheme is insensitive to the noise associated with the nonunit efficiency of the detector in the homodyne detection measurement scheme.

Physical Review A•Apr 23, 2003•11 citations
Balanced homodyne detection relies on a beam splitter to superpose the weak signal input and strong local oscillator. However, recent investigation shows that a high gain phase sensitive amplifier (PSA) can be viewed as homodyne detector, in which the strong pump of PSA serves as the local oscillator [1]. Here, we analyze a new method of measuring the continuous variable entanglement by assisting a balanced homodyne detector with the PSA and implement it experimentally. Before measuring quadrature amplitude with the balanced homodyne detectors, two entangled fields generated from a pulse pumped fiber optical parametric amplifier are simultaneously coupled into the PSA. We find that the normalized noise for both the difference and sum of the quadrature amplitudes of the two entangled fields fall below the shot noise limit by about 4.6 dB, which is the record degree of entanglement measured in optical fiber systems. The experimental results illustrate that the advantages of the new measurement method include but not limit to tolerance to detection loss and characterizing entanglement with only one homodyne detector. The influence of mode-mismatching due to multi-mode property of entanglement on the measured noise reduction can also be greatly mitigated, indicating the new method is advantageous over the traditional measurement in multi-mode case.
The traditional method for measuring Einstein-Podolsky-Rosen-type continuous-variable quantum entanglement relies on balanced homodyne detections, which are sensitive to vacuum quantum noise coupled in through losses due to various factors such as detector quantum efficiency and mode mismatching between the detected field and the local oscillator. In this paper, we propose and analyze a measurement method, which is realized by assisting the balanced homodyne detections with a high-gain phase-sensitive parametric amplifier. The employment of the phase-sensitive amplifier helps us to tackle the vacuum quantum noise originating from detection losses. Moreover, because the high-gain phase-sensitive amplifier can couple two fields of different types, the proposed scheme can be used to reveal quantum entanglement between two fields of different types by using only one balanced homodyne detection. Furthermore, detailed analysis shows that in the multimode case, the proposed scheme is also advantageous over the traditional method. Such a measurement method should find wide applications in quantum information and quantum metrology involving measurement of continuous variables.
We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses. In this systematic review, both full SU(1,1) interferometers with two parametric amplifiers and the truncated interferometers with only one parametric amplifier are examined. We investigate scenarios involving both single-output ports and joint homodyne detection, and consider parametric amplifiers with equal gains or with a boosted gain second amplifier. Our analytical formulation provides physical insight and understanding of the improvements in the sensitivity, which are shown to originate from noise reduction and/or signal amplification, depending on the configurations and practical implementations. Surprisingly, the configuration with single-output mode detection and parametric amplifiers with equal gains exhibits the highest robustness to very high internal losses. We finally apply this framework to a ubiquitous ∣α,0⟩|α,0\rangle∣α,0⟩ input two-mode coherent probe state. This approach permits the comparison of different strategies and the optimization of the interferometer performance in the presence of losses. In particular, we determine which amplification and detection configurations provide the best performance, depending on the level of losses. This exemplifies how this general analytical approach provides a powerful tool to design quantum-enhanced interferometers and achieve optimal sensitivity with selected probe states and homodyne detection.
We propose a model for the measurement of an arbitrary multimode entangled state of the cavity field using two-photon correlated emission laser. We consider two cases: (a) The modes have different frequencies and are detected separately and (b) the modes consist of two orthogonal polarization states and are detected using a single balanced homodyne detector. The basic idea is to amplify the initial multimode state such that there is no-noise in the quadrature of interest and all the noise is fed into the conjugate quadrature component. The amplified noise-free quadrature is prepared in different phases and then corresponding quadrature distribution is measured. The Wigner function of the initial multimode entangled state is then reconstructed by using inverse Radon transformation. This scheme is insensitive to the noise associated with the nonunit efficiency of the detector in the homodyne detection measurement scheme.