The work achieved in the frame of this PhD training consisted in the implementation of a cavity enhanced non destructive detection system of atoms trapped in an optical lattice aiming at improving the stability of an optical strontium clock.The characterization of the system in its classical regime, for which a sufficiently low number of photons are scattered per atom to avoid expelling them off the trap, highlighted significant improvements in term of signal to noise ratio, with gain factor around 100 compared with the previously used fluorescence scheme. Yet, gains in terms of stability via Dick effect reduction still have to be demonstrated.Regarding the quantum regime, for which less than one photon is scattered per atom over the detection, new ideas and significant changes have been carried out on the system and a theoretical study was has been undertaken to determine the strategy for the improvement of the clock stability by quantum projection noise reduction via quantum non demolition measurement.It was as well the opportunity to study the effect of the hot collisions between the trapped strontium atoms and the residual vacuum background gas particles, allowing for the improvement of the clock uncertainty. This work reports in particular on the first measurement of strontium clock hot collisions shifts as well as its theoretical study.

DOI
10.70675/85e7973fz4a2cz4b98zab1czbc647c3921c1

Related papers

Cavity non destructive detection on an optical lattice clock

Grégoire Vallet

Détection non destructive en cavité pour des horloges à réseau optique au strontium Les travaux réalisés dans le cadre de cette thèse ont consisté en la réalisation d'un système de détection non destructif assisté par cavité d'atomes piégés sur réseau optique pour l'amélioration de la stabilité d'une horloge optique au strontium. La caractérisation de ce système dans son fonctionnement en régime classique, dans lequel les atomes piégés diffusent suffisamment peu de photons pour ne pas être expulsés du piège durant la détection, a mis en évidence des améliorations significatives en termes de rapport signal à bruit avec un gain d'un facteur cent en comparaison avec le système précédent de détection par fluorescence. Les gains en termes de stabilité par réduction de l'effet Dick restent cependant à concrétiser.Pour la réalisation du régime quantique, dans lequel moins d'un photon est diffusé par atome durant la détection, des idées nouvelles et des changements significatifs ont du être opérés sur le système et un travail théorique conséquent a été entrepris afin de déterminer la stratégie permettant une amélioration de la stabilité par réduction du bruit de projection quantique par mesure sans démolition de la cohérence de l'état interne atomique.J'y ai également aborder l'étude des effets des collisions chaudes des atomes de strontium piégés avec les particules du fond de vide résiduel, permettant une amélioration de l'exactitude de l'horloge. Cette thèse rapporte en particulier la première mesure expérimentale du déplacement de la fréquence de transition d'horloge due à ces collisions ainsi que son étude théorique.

•Dec 13, 2018•0 citations

Horloge à réseau optique au Strontium : en quête de la performance ultime

Philip G. Westergaard

This thesis presents the latest achievements regarding the Sr optical lattice clock experiment at LNE-SYRTE, Observatoire de Paris. After having described the general principles for optical lattice clocks and the operation of the clock in question, the emphasis is put on the features that have been added to the experiment since 2007. The most important new elements are an ultra-stable reference cavity for the clock laser, the development of a non-destructive detection technique, and the construction of a second Sr lattice clock. The ultra-stable cavity is constructed from a ULE spacer and fused silica mirrors and has shown a thermal noise floor at 6.5E-16, placing it among the best in the world. The non-destructive detection is effectuated by a phase measurement of a weak probe beam that traverses the atoms placed in one arm of a Mach-Zender interferometer. The non-destructive aspect enables a recycling of the atoms from cycle to cycle which consequently increases the duty cycle, allowing for an increase of the stability of the clock. With these new tools the frequency stability is expected to be 2.2E-16/tau^(1/2) for an optimized sequence. The most recent comparisons between the two Sr clocks reach an accuracy level of 1E-16 after about 1000 s, and this way we have been able to characterize lattice related frequency shifts with an unprecedented accuracy. The measurements ensure a control of lattice related effects at the 1E-18 level even for trap depths as large as 50 Er.

•Jan 1, 2010•0 citations

Quantum Nondemolition Detection for Strontium Optical Lattice Clock

Haosen Shang, Miguel A. Cifuentes Marin, Yannick Foucault +2 more

SummaryThe short-term frequency instability of the best optical atomic clock lies in the mid 10−17. However, the Dick effect is still an obstacle for a single operational clock closely followed by the quantum projection noise. To improve the frequency stability of the strontium optical lattice clock, we present a quantum non-demolition detection scheme based on the cavity mediated interaction between the atoms and a probe light that has a large-frequency detuning to the atomic resonance, aiming to bring the detection scheme proposed in [1] to the quantum regime. We obtained a rather small photon scattering rate, measured to be less than 0.1 photon/μs/atom, which allows us to not only preserve the atoms in the lattice but also the atomic wave function as long as the total probe time is on the order of a few microseconds. The detection noise for the number of atoms is 48/√photons atoms, implying that the frequency stability can surpass the standard quantum limit when the number of trapped atoms is larger than 2.3×104with spin squeezing protocols.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 24, 2022•1 citation

A noise-immune cavity-assisted non-destructive detection for an optical lattice clock in the quantum regime

Grégoire Vallet, Eva Bookjans, Ulrich Eismann +3 more

We present and implement a non-destructive detection scheme for the transition probability readout of an optical lattice clock. The scheme relies on a differential heterodyne measurement of the dispersive properties of lattice-trapped atoms enhanced by a high finesse cavity. By design, this scheme offers a 1st order rejection of the technical noise sources, an enhanced signal-to-noise ratio, and an homogeneous atom-cavity coupling. We theoretically show that this scheme is optimal with respect to the photon shot noise limit. We experimentally realise this detection scheme in an operational strontium optical lattice clock. The resolution is on the order of a few atoms with a photon scattering rate low enough to keep the atoms trapped after detection. This scheme opens the door to various different interrogations protocols, which reduce the frequency instability, including atom recycling, zero-dead time clocks with a fast repetition rate, and sub quantum projection noise frequency stability.

arXiv:1703.04609•New Journal of Physics•Aug 7, 2017•51 citations

Strontium Optical Lattice Clock: In Quest of the Ultimate Performance

Philip G. Westergaard

This thesis presents the latest achievements regarding the Sr optical lattice clock experiment at LNE-SYRTE, Observatoire de Paris. After having described the general principles for optical lattice clocks and the operation of the clock in question, the emphasis is put on the features that have been added to the experiment since 2007. The most important new elements are an ultra-stable reference cavity for the clock laser, the development of a non-destructive detection technique, and the construction of a second Sr lattice clock. The ultra-stable cavity is constructed from a ULE spacer and fused silica mirrors and has shown a thermal noise floor at 6.5E-16, placing it among the best in the world. The non-destructive detection is effectuated by a phase measurement of a weak probe beam that traverses the atoms placed in one arm of a Mach-Zender interferometer. The non-destructive aspect enables a recycling of the atoms from cycle to cycle which consequently increases the duty cycle, allowing for an increase of the stability of the clock. With these new tools the frequency stability is expected to be 2.2E-16/tau^(1/2) for an optimized sequence. The most recent comparisons between the two Sr clocks reach an accuracy level of 1E-16 after about 1000 s, and this way we have been able to characterize lattice related frequency shifts with an unprecedented accuracy. The measurements ensure a control of lattice related effects at the 1E-18 level even for trap depths as large as 50 Er.

•Oct 29, 2010•2 citations

Cavity-enhanced non-destructive detection of atoms for an optical lattice clock

Richard Hobson, William Bowden, Alvise Vianello +2 more

atoms, to reject technical noise sources, to achieve signal to noise ratio close to the photon shot noise limit, to provide spatially uniform atom-cavity coupling, and to minimize inhomogeneous ac Stark shifts. These features enable detection of atoms with minimal perturbation to the atomic state, a critical step towards realizing an ultra-high-stability, quantum-enhanced optical lattice clock.

arXiv:1912.09874•Optics Express•Dec 9, 2019•21 citations
The work achieved in the frame of this PhD training consisted in the implementation of a cavity enhanced non destructive detection system of atoms trapped in an optical lattice aiming at improving the stability of an optical strontium clock.The characterization of the system in its classical regime, for which a sufficiently low number of photons are scattered per atom to avoid expelling them off the trap, highlighted significant improvements in term of signal to noise ratio, with gain factor around 100 compared with the previously used fluorescence scheme. Yet, gains in terms of stability via Dick effect reduction still have to be demonstrated.Regarding the quantum regime, for which less than one photon is scattered per atom over the detection, new ideas and significant changes have been carried out on the system and a theoretical study was has been undertaken to determine the strategy for the improvement of the clock stability by quantum projection noise reduction via quantum non demolition measurement.It was as well the opportunity to study the effect of the hot collisions between the trapped strontium atoms and the residual vacuum background gas particles, allowing for the improvement of the clock uncertainty. This work reports in particular on the first measurement of strontium clock hot collisions shifts as well as its theoretical study.
Détection non destructive en cavité pour des horloges à réseau optique au strontium Les travaux réalisés dans le cadre de cette thèse ont consisté en la réalisation d'un système de détection non destructif assisté par cavité d'atomes piégés sur réseau optique pour l'amélioration de la stabilité d'une horloge optique au strontium. La caractérisation de ce système dans son fonctionnement en régime classique, dans lequel les atomes piégés diffusent suffisamment peu de photons pour ne pas être expulsés du piège durant la détection, a mis en évidence des améliorations significatives en termes de rapport signal à bruit avec un gain d'un facteur cent en comparaison avec le système précédent de détection par fluorescence. Les gains en termes de stabilité par réduction de l'effet Dick restent cependant à concrétiser.Pour la réalisation du régime quantique, dans lequel moins d'un photon est diffusé par atome durant la détection, des idées nouvelles et des changements significatifs ont du être opérés sur le système et un travail théorique conséquent a été entrepris afin de déterminer la stratégie permettant une amélioration de la stabilité par réduction du bruit de projection quantique par mesure sans démolition de la cohérence de l'état interne atomique.J'y ai également aborder l'étude des effets des collisions chaudes des atomes de strontium piégés avec les particules du fond de vide résiduel, permettant une amélioration de l'exactitude de l'horloge. Cette thèse rapporte en particulier la première mesure expérimentale du déplacement de la fréquence de transition d'horloge due à ces collisions ainsi que son étude théorique.
This thesis presents the latest achievements regarding the Sr optical lattice clock experiment at LNE-SYRTE, Observatoire de Paris. After having described the general principles for optical lattice clocks and the operation of the clock in question, the emphasis is put on the features that have been added to the experiment since 2007. The most important new elements are an ultra-stable reference cavity for the clock laser, the development of a non-destructive detection technique, and the construction of a second Sr lattice clock. The ultra-stable cavity is constructed from a ULE spacer and fused silica mirrors and has shown a thermal noise floor at 6.5E-16, placing it among the best in the world. The non-destructive detection is effectuated by a phase measurement of a weak probe beam that traverses the atoms placed in one arm of a Mach-Zender interferometer. The non-destructive aspect enables a recycling of the atoms from cycle to cycle which consequently increases the duty cycle, allowing for an increase of the stability of the clock. With these new tools the frequency stability is expected to be 2.2E-16/tau^(1/2) for an optimized sequence. The most recent comparisons between the two Sr clocks reach an accuracy level of 1E-16 after about 1000 s, and this way we have been able to characterize lattice related frequency shifts with an unprecedented accuracy. The measurements ensure a control of lattice related effects at the 1E-18 level even for trap depths as large as 50 Er.
SummaryThe short-term frequency instability of the best optical atomic clock lies in the mid 10−17. However, the Dick effect is still an obstacle for a single operational clock closely followed by the quantum projection noise. To improve the frequency stability of the strontium optical lattice clock, we present a quantum non-demolition detection scheme based on the cavity mediated interaction between the atoms and a probe light that has a large-frequency detuning to the atomic resonance, aiming to bring the detection scheme proposed in [1] to the quantum regime. We obtained a rather small photon scattering rate, measured to be less than 0.1 photon/μs/atom, which allows us to not only preserve the atoms in the lattice but also the atomic wave function as long as the total probe time is on the order of a few microseconds. The detection noise for the number of atoms is 48/√photons atoms, implying that the frequency stability can surpass the standard quantum limit when the number of trapped atoms is larger than 2.3×104with spin squeezing protocols.
We present and implement a non-destructive detection scheme for the transition probability readout of an optical lattice clock. The scheme relies on a differential heterodyne measurement of the dispersive properties of lattice-trapped atoms enhanced by a high finesse cavity. By design, this scheme offers a 1st order rejection of the technical noise sources, an enhanced signal-to-noise ratio, and an homogeneous atom-cavity coupling. We theoretically show that this scheme is optimal with respect to the photon shot noise limit. We experimentally realise this detection scheme in an operational strontium optical lattice clock. The resolution is on the order of a few atoms with a photon scattering rate low enough to keep the atoms trapped after detection. This scheme opens the door to various different interrogations protocols, which reduce the frequency instability, including atom recycling, zero-dead time clocks with a fast repetition rate, and sub quantum projection noise frequency stability.
This thesis presents the latest achievements regarding the Sr optical lattice clock experiment at LNE-SYRTE, Observatoire de Paris. After having described the general principles for optical lattice clocks and the operation of the clock in question, the emphasis is put on the features that have been added to the experiment since 2007. The most important new elements are an ultra-stable reference cavity for the clock laser, the development of a non-destructive detection technique, and the construction of a second Sr lattice clock. The ultra-stable cavity is constructed from a ULE spacer and fused silica mirrors and has shown a thermal noise floor at 6.5E-16, placing it among the best in the world. The non-destructive detection is effectuated by a phase measurement of a weak probe beam that traverses the atoms placed in one arm of a Mach-Zender interferometer. The non-destructive aspect enables a recycling of the atoms from cycle to cycle which consequently increases the duty cycle, allowing for an increase of the stability of the clock. With these new tools the frequency stability is expected to be 2.2E-16/tau^(1/2) for an optimized sequence. The most recent comparisons between the two Sr clocks reach an accuracy level of 1E-16 after about 1000 s, and this way we have been able to characterize lattice related frequency shifts with an unprecedented accuracy. The measurements ensure a control of lattice related effects at the 1E-18 level even for trap depths as large as 50 Er.