Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Optimization of a magneto–optic trap using nanofibers*

Xin Wang, Li-Jun Song, Chenxi Wang, Pengfei Zhang, Gang Li, Tiancai Zhang

Published Jul 1, 2019• 7 citations
Publisher

Abstract

We experimentally demonstrate a reliable method based on a nanofiber to optimize the number of cold atoms in a magneto–optical trap (MOT) and to monitor the MOT in real time. The atomic fluorescence is collected by a nanofiber with subwavelength diameter of about 400 nm. The MOT parameters are experimentally adjusted in order to match the maximum number of cold atoms provided by the fluorescence collected by the nanofiber. The maximum number of cold atoms is obtained when the intensities of the cooling and re-pumping beams are about 23.5 mW/cm2 and 7.1 mW/cm2, respectively; the detuning of the cooling beam is −13.0 MHz, and the axial magnetic gradient is about 9.7 Gauss/cm. We observe a maximum photon counting rate of nearly (4.5±0.1) × 105 counts/s. The nanofiber–atom system can provide a powerful and flexible tool for sensitive atom detection and for monitoring atom–matter coupling. It can be widely used from quantum optics to quantum precision measurement.

DOI
10.1088/1674-1056/28/7/073701

Related papers

Tapered optical fibers as tools for probing magneto-optical trap characteristics

Michael Morrissey, Kieran Deasy, Yuqiang Wu +2 more

We present a novel technique for measuring the characteristics of a magneto-optical trap (MOT) for cold atoms by monitoring the spontaneous emission from trapped atoms coupled into the guided mode of a tapered optical nanofiber. We show that the nanofiber is highly sensitive to very small numbers of atoms close to its surface. The size and shape of the MOT, determined by translating the cold atom cloud across the tapered fiber, is in excellent agreement with measurements obtained using the conventional method of fluorescence imaging using a charge coupled device camera. The coupling of atomic fluorescence into the tapered fiber also allows us to monitor the loading and lifetime of the trap. The results are compared to those achieved by focusing the MOT fluorescence onto a photodiode and it was seen that the tapered fiber gives slightly longer loading and lifetime measurements due to the sensitivity of the fiber, even when very few atoms are present.

arXiv:0903.2953•Review of Scientific Instruments•May 1, 2009•74 citations

Measurements on release-recapture of cold 85Rb atoms using an optical nanofibre in a magneto-optical trap

We have performed release-recapture temperature measurements of laser-cooled 85Rb atoms using an optical nanofibre (ONF) in a magneto-optical trap (MOT). The effects of changing the cooling laser light-shift parameter on the temperature of the cold atoms and spring constant of the trap are studied. By varying the cold atom number density near the ONF, the onset of the multiple scattering regime is observed without the need for an estimation of the atom cloud size. Moreover, this sensitive ONF assisted release-recapture technique is easily able to detect any optical misalignment of the cooling laser beams in the MOT. Keywords: laser cooling, optical nanofiber, rubidium, release-recapture, temperature

•Aug 17, 2016•31 citations

Optimization of the light-induced-fluorescence signals of single atoms and efficient loading of single atoms into a magneto-optical trap

Jieying Wang, Bei Liu, Diao Wen-Ting +3 more

In our experiment, firstly, we carry out the loading of single atoms in the magneto-optical trap (MOT) by increasing the quadrupole magnetic field gradient, improving the background vacuum, and reducing the diameters of the cooling and trapping laser beams. Secondly, we get the single atomic fluorescence signal of a high signal-to-background ratio in the MOT by means of reducing the detuning of cooling light and increasing its intensity appropriately, and using the polarization spectroscopy locking technique to suppress the fluctuations of cooling laser. In addition, with the real-time feedback on quadrupole magnetic field gradient, we demonstrate a probability of loading single atoms in the MOT as high as 98%. We also measure the statistical properties of the single atomic fluorescence which is excited by continuous light in the MOT; the measured second-order correlation is g(2)( = 0) = 0.09.

Acta Physica Sinica•Jan 1, 2014•3 citations

Tapered optical nanofiber for light-atom interfacing

Aveek Chandra

This project aims to develop scientific as well as technical foundations towards realization of a novel platform for light-matter interaction based on tapered optical nanofibers that enable to interface neutral atoms in their vicinity. A setup for magneto-optical trap (MOT) has been built. Tapered nanofibers (TNFs) of sub-wavelength diameter, with transmission of 95 percent have been fabricated and characterized. Next, a nanofiber is transferred into the MOT setup and installed inside the vacuum chamber. The MOT cloud and nanofiber are made to spatially overlap inside ultra-high vacuum (UHV). Coupling of fluorescence of MOT into the guided mode of TNF has been observed. This clearly shows the coupling of atoms with the fiber-guided mode and that our interface works. In addition, 65-70 percent absorption of a free space beam by the atomic cloud has been observed and the relevant MOT parameters are obtained from it. Our efforts are directed towards observing interaction of atoms with the fiber-guided light via evanescent field. Attempts have been made to observe absorption of a probe beam through the nanofiber by the MOT cloud and techniques for switching on-off the MOT beams, the probe beam and the magnetic field are developed for that purpose. Ultimately, the goal will be to trap atoms in the vicinity of a nanofiber enabling to reach a large optical depth accompanied by the ability to reach high intensities for low optical power. I will present my work on the development of this MOT-nanofiber interface - a new promising platform for research in nonlinear quantum optics, quantum information science and technology, quantum communication and hybrid quantum system.

•Jan 1, 2014•0 citations

Detection of a single lithium atom in a magneto-optical trap

Hyok Sang Han, Seokchan Yoon, D. Cho

We report fluorescence detection of a single 7 Li atom in a magneto-optical trap (MOT). We use a double MOT system, which allows us to control the loading rate of the second MOT by simply turning on or off the first MOT and to use a modest magnetic field gradient of 46 G/cm. A single atom is trapped for longer than 100 s. The fluorescence from the trapped atoms is imaged onto an electron-multiplying charge-coupled device with a unit magnification factor by a pair of aspheric lenses. The numerical aperture of the objective lens is 0.22 with a collecting efficiency of 1.3%. Accumulated fluorescence is extracted by integrating the signal over a region of interest of 500×350 μ m 2 . For a 200-ms exposure time, the fluorescence count from a single atom is 8.8×10 3 and the background count from scattered MOT beams is 6.8 × 10 4 . We actively stabilize the trap beam power to reduce the noise and the measured noise is two times the statistical noise. Overall signal-to-noise ratio of the single-atom detection is 37/√ Hz. We also describe a modification of the system that is adapted to an experimental configuration for quantum manipulation of single atoms in a 1D optical lattice.

Journal of the Korean Physical Society•Jun 1, 2015•4 citations

Single-atom counting in a two-color magneto-optical trap

Martin Schlederer, Alexandra Mozdzen, Thomas Lompe +1 more

Recording the fluorescence of a magneto-optical trap (MOT) is a standard tool for measuring atom numbers in experiments with ultracold atoms. When trapping few atoms in a small MOT, the emitted fluorescence increases with the atom number in discrete steps, which allows one to measure the atom number with single-particle resolution. Achieving such single-particle resolution requires stringent minimization of stray light from the MOT beams, which is very difficult to achieve in experimental setups that require in-vacuum components close to the atoms. Here, we present a modified scheme that addresses this issue: Instead of collecting the fluorescence on the MOT (D2) transition, we scatter light on an additional probing (D1) transition and collect this fluorescence with a high-resolution microscope while filtering out the intense MOT light. Using this scheme, we are able to reliably distinguish up to 17 $^{40}\mathrm{K}$ atoms with classification fidelities of $\ensuremath{\sim}98%$ for up to 5 atom numbers and fidelities of more than 85% for up to 17 atoms.

arXiv:2011.10081•Physical Review A•Mar 12, 2021•3 citations
We experimentally demonstrate a reliable method based on a nanofiber to optimize the number of cold atoms in a magneto–optical trap (MOT) and to monitor the MOT in real time. The atomic fluorescence is collected by a nanofiber with subwavelength diameter of about 400 nm. The MOT parameters are experimentally adjusted in order to match the maximum number of cold atoms provided by the fluorescence collected by the nanofiber. The maximum number of cold atoms is obtained when the intensities of the cooling and re-pumping beams are about 23.5 mW/cm2 and 7.1 mW/cm2, respectively; the detuning of the cooling beam is −13.0 MHz, and the axial magnetic gradient is about 9.7 Gauss/cm. We observe a maximum photon counting rate of nearly (4.5±0.1) × 105 counts/s. The nanofiber–atom system can provide a powerful and flexible tool for sensitive atom detection and for monitoring atom–matter coupling. It can be widely used from quantum optics to quantum precision measurement.
We present a novel technique for measuring the characteristics of a magneto-optical trap (MOT) for cold atoms by monitoring the spontaneous emission from trapped atoms coupled into the guided mode of a tapered optical nanofiber. We show that the nanofiber is highly sensitive to very small numbers of atoms close to its surface. The size and shape of the MOT, determined by translating the cold atom cloud across the tapered fiber, is in excellent agreement with measurements obtained using the conventional method of fluorescence imaging using a charge coupled device camera. The coupling of atomic fluorescence into the tapered fiber also allows us to monitor the loading and lifetime of the trap. The results are compared to those achieved by focusing the MOT fluorescence onto a photodiode and it was seen that the tapered fiber gives slightly longer loading and lifetime measurements due to the sensitivity of the fiber, even when very few atoms are present.
We have performed release-recapture temperature measurements of laser-cooled 85Rb atoms using an optical nanofibre (ONF) in a magneto-optical trap (MOT). The effects of changing the cooling laser light-shift parameter on the temperature of the cold atoms and spring constant of the trap are studied. By varying the cold atom number density near the ONF, the onset of the multiple scattering regime is observed without the need for an estimation of the atom cloud size. Moreover, this sensitive ONF assisted release-recapture technique is easily able to detect any optical misalignment of the cooling laser beams in the MOT. Keywords: laser cooling, optical nanofiber, rubidium, release-recapture, temperature
In our experiment, firstly, we carry out the loading of single atoms in the magneto-optical trap (MOT) by increasing the quadrupole magnetic field gradient, improving the background vacuum, and reducing the diameters of the cooling and trapping laser beams. Secondly, we get the single atomic fluorescence signal of a high signal-to-background ratio in the MOT by means of reducing the detuning of cooling light and increasing its intensity appropriately, and using the polarization spectroscopy locking technique to suppress the fluctuations of cooling laser. In addition, with the real-time feedback on quadrupole magnetic field gradient, we demonstrate a probability of loading single atoms in the MOT as high as 98%. We also measure the statistical properties of the single atomic fluorescence which is excited by continuous light in the MOT; the measured second-order correlation is g(2)( = 0) = 0.09.
This project aims to develop scientific as well as technical foundations towards realization of a novel platform for light-matter interaction based on tapered optical nanofibers that enable to interface neutral atoms in their vicinity. A setup for magneto-optical trap (MOT) has been built. Tapered nanofibers (TNFs) of sub-wavelength diameter, with transmission of 95 percent have been fabricated and characterized. Next, a nanofiber is transferred into the MOT setup and installed inside the vacuum chamber. The MOT cloud and nanofiber are made to spatially overlap inside ultra-high vacuum (UHV). Coupling of fluorescence of MOT into the guided mode of TNF has been observed. This clearly shows the coupling of atoms with the fiber-guided mode and that our interface works. In addition, 65-70 percent absorption of a free space beam by the atomic cloud has been observed and the relevant MOT parameters are obtained from it. Our efforts are directed towards observing interaction of atoms with the fiber-guided light via evanescent field. Attempts have been made to observe absorption of a probe beam through the nanofiber by the MOT cloud and techniques for switching on-off the MOT beams, the probe beam and the magnetic field are developed for that purpose. Ultimately, the goal will be to trap atoms in the vicinity of a nanofiber enabling to reach a large optical depth accompanied by the ability to reach high intensities for low optical power. I will present my work on the development of this MOT-nanofiber interface - a new promising platform for research in nonlinear quantum optics, quantum information science and technology, quantum communication and hybrid quantum system.
We report fluorescence detection of a single 7 Li atom in a magneto-optical trap (MOT). We use a double MOT system, which allows us to control the loading rate of the second MOT by simply turning on or off the first MOT and to use a modest magnetic field gradient of 46 G/cm. A single atom is trapped for longer than 100 s. The fluorescence from the trapped atoms is imaged onto an electron-multiplying charge-coupled device with a unit magnification factor by a pair of aspheric lenses. The numerical aperture of the objective lens is 0.22 with a collecting efficiency of 1.3%. Accumulated fluorescence is extracted by integrating the signal over a region of interest of 500×350 μ m 2 . For a 200-ms exposure time, the fluorescence count from a single atom is 8.8×10 3 and the background count from scattered MOT beams is 6.8 × 10 4 . We actively stabilize the trap beam power to reduce the noise and the measured noise is two times the statistical noise. Overall signal-to-noise ratio of the single-atom detection is 37/√ Hz. We also describe a modification of the system that is adapted to an experimental configuration for quantum manipulation of single atoms in a 1D optical lattice.
Recording the fluorescence of a magneto-optical trap (MOT) is a standard tool for measuring atom numbers in experiments with ultracold atoms. When trapping few atoms in a small MOT, the emitted fluorescence increases with the atom number in discrete steps, which allows one to measure the atom number with single-particle resolution. Achieving such single-particle resolution requires stringent minimization of stray light from the MOT beams, which is very difficult to achieve in experimental setups that require in-vacuum components close to the atoms. Here, we present a modified scheme that addresses this issue: Instead of collecting the fluorescence on the MOT (D2) transition, we scatter light on an additional probing (D1) transition and collect this fluorescence with a high-resolution microscope while filtering out the intense MOT light. Using this scheme, we are able to reliably distinguish up to 17 40K^{40}\mathrm{K}40K atoms with classification fidelities of $\ensuremath{\sim}98%$ for up to 5 atom numbers and fidelities of more than 85% for up to 17 atoms.