Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optimal two-mode coherent states in lossy quantum-enhanced metrology

Su‐Yong Lee, Yong Sup Ihn, Zaeill Kim

Published Jun 12, 2019• 1 citation
OpenAlex

Related papers

Quantum-enhanced metrology with the single-mode coherent states of an optical cavity inside a quantum feedback loop

AM Clark, A Stokes, A Beige

•Aug 23, 2016•0 citations

Optimal entangled coherent states in lossy quantum-enhanced metrology

Su‐Yong Lee, Yong Sup Ihn, Zaeill Kim

We investigate an optimal distance of two components in an entangled coherent state for quantum phase estimation in lossy interferometry. The optimal distance is obtained by an economical point, representing the quantum Fisher information that we can extract per input energy. Maximizing the formula of the quantum Fisher information over an input mean photon number, we show that, as the losses of the interferometer increase, it can be more beneficial to prepare an initially entangled coherent state that is less entangled. This represents that the optimal distance of the two-mode components decreases with more loss in the interferometry. Under the constraint of the input mean photon number, we obtain that the optimal entangled coherent state is more robust than a separable coherent state, even in a high photon loss rate. The optimal entangled coherent state preserves quantum advantage over the standard interferometric limit of the separable coherent state. We also show that the corresponding optimal measurement requires correlation measurement bases.

arXiv:1906.05402•Physical Review A•Jan 21, 2020•22 citations

Exceptional-point-enhanced quantum metrology in a non-Hermitian quantum coherent system

Xuan Fu, Xuesong Hu, Hancheng Liu +7 more

Optics & Laser Technology•May 16, 2026•0 citations

Coherent feedback enhanced quantum-dense metrology in a lossy environment

Xinyun Liang, Jie Zhao, Yuhan Yan +3 more

Quantum dense metrology (QDM) performs high-precision measurements by a two-mode entangled state created by an optical parametric amplifier (PA), where one mode is a meter beam and the other is a reference beam. In practical applications, the photon losses of meter beam are unavoidable, resulting in a degradation of the sensitivity. Here, we employ coherent feedback that feeds the reference beam back into the PA by a beam splitter to enhance the sensitivity in a lossy environment. The results show that the sensitivity is enhanced significantly by adjusting the splitting ratio of the beam splitter. This method may find its potential applications in QDM. Furthermore, such a strategy that two non-commuting observables are simultaneous measurements could provide a new way to individually control the noise-induced random drift in phase or amplitude of the light field, which would be significant for stabilizing the system and long-term precision measurement.

Optics Express•Mar 13, 2024•3 citations

Experimental demonstration of nonlinear quantum metrology with optimal quantum state

Xinfang Nie, Jiahao Huang, Zhaokai Li +4 more

中国科学通报:英文版•Mar 19, 2018•20 citations

Practical resources and measurements for lossy optical quantum metrology

Changhun Oh, Su-Yong Lee, Hyunchul Nha +1 more

We study the sensitivity of phase estimation in a lossy Mach-Zehnder interferometer (MZI) using two general, and practical, resources generated by a laser and a nonlinear optical medium with passive optimal elements, which are readily available in the laboratory: One is a two-mode separable coherent and squeezed vacuum state at a beam splitter and the other is a two-mode squeezed vacuum state. In view of the ultimate precision given by quantum Fisher information, we show that the two-mode squeezed vacuum state can achieve a lower bound of estimation error than the coherent and squeezed vacuum state under a photon-loss channel. We further consider practical measurement schemes, homodyne detection and photon number resolving detection (PNRD), to characterize the accuracy of phase estimation in reality and find that the coherent and squeezed vacuum state largely achieves a lower bound than the two-mode squeezed vacuum in the lossy MZI while maintaining quantum enhancement over the shot-noise limit. By comparing homodyne detection and PNRD, we demonstrate that quadrature measurement with homodyne detection is more robust against photon loss than parity measurement with PNRD. We also show that double homodyne detection can provide a better tool for phase estimation than single homodyne detection against photon loss.

arXiv:1707.03210•Physical Review A•Dec 4, 2017•37 citations
We investigate an optimal distance of two components in an entangled coherent state for quantum phase estimation in lossy interferometry. The optimal distance is obtained by an economical point, representing the quantum Fisher information that we can extract per input energy. Maximizing the formula of the quantum Fisher information over an input mean photon number, we show that, as the losses of the interferometer increase, it can be more beneficial to prepare an initially entangled coherent state that is less entangled. This represents that the optimal distance of the two-mode components decreases with more loss in the interferometry. Under the constraint of the input mean photon number, we obtain that the optimal entangled coherent state is more robust than a separable coherent state, even in a high photon loss rate. The optimal entangled coherent state preserves quantum advantage over the standard interferometric limit of the separable coherent state. We also show that the corresponding optimal measurement requires correlation measurement bases.
Quantum dense metrology (QDM) performs high-precision measurements by a two-mode entangled state created by an optical parametric amplifier (PA), where one mode is a meter beam and the other is a reference beam. In practical applications, the photon losses of meter beam are unavoidable, resulting in a degradation of the sensitivity. Here, we employ coherent feedback that feeds the reference beam back into the PA by a beam splitter to enhance the sensitivity in a lossy environment. The results show that the sensitivity is enhanced significantly by adjusting the splitting ratio of the beam splitter. This method may find its potential applications in QDM. Furthermore, such a strategy that two non-commuting observables are simultaneous measurements could provide a new way to individually control the noise-induced random drift in phase or amplitude of the light field, which would be significant for stabilizing the system and long-term precision measurement.
We study the sensitivity of phase estimation in a lossy Mach-Zehnder interferometer (MZI) using two general, and practical, resources generated by a laser and a nonlinear optical medium with passive optimal elements, which are readily available in the laboratory: One is a two-mode separable coherent and squeezed vacuum state at a beam splitter and the other is a two-mode squeezed vacuum state. In view of the ultimate precision given by quantum Fisher information, we show that the two-mode squeezed vacuum state can achieve a lower bound of estimation error than the coherent and squeezed vacuum state under a photon-loss channel. We further consider practical measurement schemes, homodyne detection and photon number resolving detection (PNRD), to characterize the accuracy of phase estimation in reality and find that the coherent and squeezed vacuum state largely achieves a lower bound than the two-mode squeezed vacuum in the lossy MZI while maintaining quantum enhancement over the shot-noise limit. By comparing homodyne detection and PNRD, we demonstrate that quadrature measurement with homodyne detection is more robust against photon loss than parity measurement with PNRD. We also show that double homodyne detection can provide a better tool for phase estimation than single homodyne detection against photon loss.