Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

An optical atomic clock using a single 171Yb+ ion with a characterisation of thermal systematic effects

Charles F. A. Baynham, E. A. Curtis, R. M. Godun, Jonathan M. Jones, Peter B. R. Nisbet-Jones, P. E. G. Baird, P. Gill, Thomas Fordell, Thomas Lindvall

Published Jul 1, 2018• 0 citations
OpenAlex

Related papers

An optical atomic clock based on a highly charged ion

S. A. King, Lukas J. Spieß, P. Micke +9 more

arXiv:2205.13053•Nature•Nov 2, 2022•163 citations

Trapped ion optical frequency standards

P. Gill, G. P. Barwood, Hugh A. Klein +6 more

Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.

Measurement Science and Technology•Jul 16, 2003•55 citations

Leveraging correlated laser noise to improve optical frequency comparisons

Ethan Clements, M. Bohman, May E. Kim +14 more

Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.

Optical and Quantum Sensing and Precision Metrology II•Mar 9, 2022•0 citations

Progress Towards a Multi-ion Optical Clock Based on a Linear Chain of Yb Ions.

Justin T. Schultz, N. R. Claussen, Peter D. D. Schwindt

•Jun 1, 2021•0 citations

Progress towards a compact single-ion optical clock

Marion Delehaye, Lucas Groult, Maël Souidi +5 more

•Nov 12, 2017•0 citations

Sub-kelvin temperature management in ion traps for optical clocks

T. Nordmann, Alexandre Didier, M. Doležal +3 more

The uncertainty of the ac Stark shift due to thermal radiation represents a major contribution to the systematic uncertainty budget of state-of-the-art optical atomic clocks. In the case of optical clocks based on trapped ions, the thermal behavior of the rf-driven ion trap must be precisely known. This determination is even more difficult when scalable linear ion traps are used. Such traps enable a more advanced control of multiple ions and have become a platform for new applications in quantum metrology, simulation, and computation. Nevertheless, their complex structure makes it more difficult to precisely determine its temperature in operation and thus the related systematic uncertainty. We present here scalable linear ion traps for optical clocks, which exhibit very low temperature rise under operation. We use a finite-element model refined with experimental measurements to determine the thermal distribution in the ion trap and the temperature at the position of the ions. The trap temperature is investigated at different rf-drive frequencies and amplitudes with an infrared camera and integrated temperature sensors. We show that for typical trapping parameters for In+, Al+, Lu+, Ca+, Sr+, or Yb+ ions, the temperature rise at the position of the ions resulting from rf heating of the trap stays below 700 mK and can be controlled with an uncertainty on the order of a few 100 mK maximum. The corresponding uncertainty of the trap-related blackbody radiation shift is in the low 10−19 and even 10−20 regime for 171Yb+(E3) and 115In+, respectively.

arXiv:2008.04231•Review of Scientific Instruments•Nov 1, 2020•18 citations
Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.
Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.
The uncertainty of the ac Stark shift due to thermal radiation represents a major contribution to the systematic uncertainty budget of state-of-the-art optical atomic clocks. In the case of optical clocks based on trapped ions, the thermal behavior of the rf-driven ion trap must be precisely known. This determination is even more difficult when scalable linear ion traps are used. Such traps enable a more advanced control of multiple ions and have become a platform for new applications in quantum metrology, simulation, and computation. Nevertheless, their complex structure makes it more difficult to precisely determine its temperature in operation and thus the related systematic uncertainty. We present here scalable linear ion traps for optical clocks, which exhibit very low temperature rise under operation. We use a finite-element model refined with experimental measurements to determine the thermal distribution in the ion trap and the temperature at the position of the ions. The trap temperature is investigated at different rf-drive frequencies and amplitudes with an infrared camera and integrated temperature sensors. We show that for typical trapping parameters for In+, Al+, Lu+, Ca+, Sr+, or Yb+ ions, the temperature rise at the position of the ions resulting from rf heating of the trap stays below 700 mK and can be controlled with an uncertainty on the order of a few 100 mK maximum. The corresponding uncertainty of the trap-related blackbody radiation shift is in the low 10−19 and even 10−20 regime for 171Yb+(E3) and 115In+, respectively.