Cavity-enhanced quantum metrology with internal squeezed light generation

M. Korobko, Yiqiu Ma, L. Kleybolte, S. Steinlechner, S. Ast, Haixing Miao, Y. Chen, Roman Schnabel

Published Jan 1, 2019• 0 citations
Publisher

Abstract

Optical cavities allow to increase the sensitivity in quantum metrology, at a price of reduced detection bandwidth. We propose to overcome these limitations by squeezing the quantum uncertainty directly inside the detector cavity.
DOI
10.1364/qim.2019.t5a.43

Related papers

Distributed quantum metrology with a single squeezed-vacuum source

Dario Gatto, Paolo Facchi, Frank A. Narducci +1 more

The authors present a technique to overcome the technological limitations of interferometry in quantum metrology by using squeezed light as the quantum resource, on-off detectors, and thus avoiding the need of any auxiliary interferometric channels. Their set-up achieves Heisenberg-limited sensitivity in the estimation of a linear combination of multiple phases

arXiv:1906.12294•Physical Review Research•Nov 25, 2019•51 citations

Beating the Standard Sensitivity-Bandwidth Limit of Cavity-Enhanced Interferometers with Internal Squeezed-Light Generation

M. Korobko, L. Kleybolte, S. Ast +3 more

The shot-noise limited peak sensitivity of cavity-enhanced interferometric measurement devices, such as gravitational-wave detectors, can be improved by increasing the cavity finesse, even when comparing fixed intracavity light powers. For a fixed light power inside the detector, this comes at the price of a proportional reduction in the detection bandwidth. High sensitivity over a large span of signal frequencies, however, is essential for astronomical observations. It is possible to overcome this standard sensitivity-bandwidth limit using nonclassical correlations in the light field. Here, we investigate the internal squeezing approach, where the parametric amplification process creates a nonclassical correlation directly inside the interferometer cavity. We theoretically analyze the limits of the approach and measure 36% increase in the sensitivity-bandwidth product compared to the classical case. To our knowledge, this is the first experimental demonstration of an improvement in the sensitivity-bandwidth product using internal squeezing, opening the way for a new class of optomechanical force sensing devices.

arXiv:1702.01044•Physical Review Letters•Apr 7, 2017•65 citations

Quantum-enhanced metrology with the single-mode coherent states of an optical cavity inside a quantum feedback loop

AM Clark, A Stokes, A Beige

•Aug 23, 2016•0 citations

Quantum expander for gravitational-wave observatories

Mikhail Korobko, Yiqiu Ma, Yanbei Chen +1 more

The quantum uncertainty of laser light limits the sensitivity of gravitational-wave observatories. Over the past 30 years, techniques for squeezing the quantum uncertainty, as well as for enhancing gravitational-wave signals with optical resonators have been invented. Resonators, however, have finite linewidths, and the high signal frequencies that are produced during the highly scientifically interesting ring-down of astrophysical compact-binary mergers still cannot be resolved. Here, we propose a purely optical approach for expanding the detection bandwidth. It uses quantum uncertainty squeezing inside one of the optical resonators, compensating for the finite resonators' linewidths while keeping the low-frequency sensitivity unchanged. This quantum expander is intended to enhance the sensitivity of future gravitational-wave detectors, and we suggest the use of this new tool in other cavity-enhanced metrological experiments.

arXiv:1903.05930•Light Science & Applications•Dec 11, 2019•50 citations

Quantum metrology with two-photon phase-sensitivity and single-photon detection

Panagiotis Vergyris, Florian Kaiser, Nicola Montaut +4 more

We introduce and demonstrate quantum-enhanced optical phase measurements with two-photon sensitivity and classical light detection with a standard photodiode. Our strategy paves the way towards resource-efficient and practical quantum metrology.

Quantum Information and Measurement (QIM)•Jan 1, 2017•0 citations

Squeezed light and laser interferometric gravitational wave detectors

S. Chelkowski

Based on the General Theory of Relativity Albert Einstein predicted the existence of gravitational waves as early as 1916.It took until now to develop large-scale interferometric gravitational wave (GW) detectors with sensitivities which would allow a direct measurement of a GW caused by an astrophysical event, such as a nearby supernova explosion.GW detectors have steadily improved over recent years and are currently producing a continuous stream of scientifically relevant data.The limiting noise in the higher frequency range of the GW detection band is shot noise, which is caused by vacuum fluctuations entering the detector through its dark port.Current GW detectors use high-power lasers to reduce shot noise.In addition, techniques such as power recycling and signal recycling have been developed.These techniques increase the laser power in the interferometer arms and amplify the GW induced signal sidebands respectively, to increase the shot noise limited sensitivity even further.In 1981 Caves proposed using squeezed light to reduce the vacuum fluctuations, thereby increasing the signal-to-noise ratio of the GW detector.The generation of squeezed states was first experimentally demonstrated by Slusher et al. in 1985.Since then, the technique of squeezing has evolved and today it can be used as a tool in real applications such as GW detection.It is planned to use squeezed light in future generations of GW detectors to enhance their sensitivity beyond quantum noise.This thesis analyzes and demonstrates the compatibility of squeezed light and advanced techniques of high-precision laser interferometry for GW detection.Initially, an optical parametric amplifier (OPA) is set up to produce the desired squeezed states of light (Chapter 3).This source is characterized-and consequently optimized-to deliver a maximum squeezing strength of up to 5.7 dB.The detuned signal-recycling cavity of GEO 600 and future GW detectors inevitably requires study of the effects caused by reflection of an initially frequency-independent squeezed state of light at such a cavity.The squeezing ellipse orientation of the reflected light is frequency-dependent; consequently, the sensitivity of the GW detector is only enhanced in a small frequency range.In Chapter 4 such frequency-dependent squeezed states are generated and characterized.The demonstration of a squeezed-light-enhanced dual-recycled Michelson interferometer with a broadband improved sensitivity is presented in Chapter 5. Here, a smaller version of GEO 600, downsized by a factor of 1000, is set up as a tabletop experiment.A detuned filter cavity is used to compensate the effects of the signal-recycling cavity, which results in a non-classical sensitivity improvement in the entire frequency band of interest.The enhancement of a large scale GW detector demands the availability of squeezed light in the GW detection band from 10 Hz-10 kHz.Chapter 6 describes the newly developed locking scheme required for the generation of such low-frequency squeezing, along with the results obtained.Finally, an outlook is given in Chapter 7 of the possible performance increase of the next generation GW detector, GEO-HF, due to squeezed-light injection.Different options for filter cavities and their implementation in the current vacuum system are discussed, as well as a detuned twin-signal-recycling option.

•Jan 1, 2007•16 citations
The shot-noise limited peak sensitivity of cavity-enhanced interferometric measurement devices, such as gravitational-wave detectors, can be improved by increasing the cavity finesse, even when comparing fixed intracavity light powers. For a fixed light power inside the detector, this comes at the price of a proportional reduction in the detection bandwidth. High sensitivity over a large span of signal frequencies, however, is essential for astronomical observations. It is possible to overcome this standard sensitivity-bandwidth limit using nonclassical correlations in the light field. Here, we investigate the internal squeezing approach, where the parametric amplification process creates a nonclassical correlation directly inside the interferometer cavity. We theoretically analyze the limits of the approach and measure 36% increase in the sensitivity-bandwidth product compared to the classical case. To our knowledge, this is the first experimental demonstration of an improvement in the sensitivity-bandwidth product using internal squeezing, opening the way for a new class of optomechanical force sensing devices.
The quantum uncertainty of laser light limits the sensitivity of gravitational-wave observatories. Over the past 30 years, techniques for squeezing the quantum uncertainty, as well as for enhancing gravitational-wave signals with optical resonators have been invented. Resonators, however, have finite linewidths, and the high signal frequencies that are produced during the highly scientifically interesting ring-down of astrophysical compact-binary mergers still cannot be resolved. Here, we propose a purely optical approach for expanding the detection bandwidth. It uses quantum uncertainty squeezing inside one of the optical resonators, compensating for the finite resonators' linewidths while keeping the low-frequency sensitivity unchanged. This quantum expander is intended to enhance the sensitivity of future gravitational-wave detectors, and we suggest the use of this new tool in other cavity-enhanced metrological experiments.
Based on the General Theory of Relativity Albert Einstein predicted the existence of gravitational waves as early as 1916.It took until now to develop large-scale interferometric gravitational wave (GW) detectors with sensitivities which would allow a direct measurement of a GW caused by an astrophysical event, such as a nearby supernova explosion.GW detectors have steadily improved over recent years and are currently producing a continuous stream of scientifically relevant data.The limiting noise in the higher frequency range of the GW detection band is shot noise, which is caused by vacuum fluctuations entering the detector through its dark port.Current GW detectors use high-power lasers to reduce shot noise.In addition, techniques such as power recycling and signal recycling have been developed.These techniques increase the laser power in the interferometer arms and amplify the GW induced signal sidebands respectively, to increase the shot noise limited sensitivity even further.In 1981 Caves proposed using squeezed light to reduce the vacuum fluctuations, thereby increasing the signal-to-noise ratio of the GW detector.The generation of squeezed states was first experimentally demonstrated by Slusher et al. in 1985.Since then, the technique of squeezing has evolved and today it can be used as a tool in real applications such as GW detection.It is planned to use squeezed light in future generations of GW detectors to enhance their sensitivity beyond quantum noise.This thesis analyzes and demonstrates the compatibility of squeezed light and advanced techniques of high-precision laser interferometry for GW detection.Initially, an optical parametric amplifier (OPA) is set up to produce the desired squeezed states of light (Chapter 3).This source is characterized-and consequently optimized-to deliver a maximum squeezing strength of up to 5.7 dB.The detuned signal-recycling cavity of GEO 600 and future GW detectors inevitably requires study of the effects caused by reflection of an initially frequency-independent squeezed state of light at such a cavity.The squeezing ellipse orientation of the reflected light is frequency-dependent; consequently, the sensitivity of the GW detector is only enhanced in a small frequency range.In Chapter 4 such frequency-dependent squeezed states are generated and characterized.The demonstration of a squeezed-light-enhanced dual-recycled Michelson interferometer with a broadband improved sensitivity is presented in Chapter 5. Here, a smaller version of GEO 600, downsized by a factor of 1000, is set up as a tabletop experiment.A detuned filter cavity is used to compensate the effects of the signal-recycling cavity, which results in a non-classical sensitivity improvement in the entire frequency band of interest.The enhancement of a large scale GW detector demands the availability of squeezed light in the GW detection band from 10 Hz-10 kHz.Chapter 6 describes the newly developed locking scheme required for the generation of such low-frequency squeezing, along with the results obtained.Finally, an outlook is given in Chapter 7 of the possible performance increase of the next generation GW detector, GEO-HF, due to squeezed-light injection.Different options for filter cavities and their implementation in the current vacuum system are discussed, as well as a detuned twin-signal-recycling option.