Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Information and Measurement (QIM)

Measuring Motion Below the Standard Quantum Limit by Strong Optomechanical Quantum Correlations

Junxin Chen, David Mason, Massimiliano Rossi, Yeghishe Tsaturyan, Albert Schließer

Published Jan 1, 2019• 0 citations
Publisher

Abstract

In interferometric displacement and force measurement, the tradeoff between imprecision noise and quantum backaction sets the standard quantum limit (SQL). By exploiting quantum correlations in an optomechanical system, we demonstrate the first sub-SQL interferometric measurement.
DOI
10.1364/qim.2019.s3c.5

Related papers

Quantum Measurement of a Mechanical Resonator at and Below the Standard Quantum Limit

Massimiliano Rossi, David Mason, Junxin Chen +2 more

Interferometrie techniques to measure mechanical displacement are subject to constraints ultimately governed by quantum mechanics. In a "standard" measurement of a mechanically induced optical phase shift, there exists a trade-off between measurement imprecision and motion disturbance, known as standard quantum limit (SQL) [1]. For a mechanical resonator with susceptibility χm(Ω), this limit is SSQL(Ω) = ħ|χm(Ω)| (ħ reduced Planck constant), at any frequency Ω. In the last half-century, a number of systems, including advanced LIGO and ultracold atoms have progressed towards this limit, but excess sources of noise have yet prevented fully reaching the SQL. Here, we show measurements of an ultracoherent mechanical resonator performed at the SQL within 33% [2] and, for the first time, below the SQL by 1.5 dB[3]. The latter has been possible by a non-standard measurement scheme that explois quantum correlations between optical quadratures induced in the optomechanical device.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2019•1 citation

Measuring nanomechanical motion with an imprecision below the standard quantum limit

G. Anetsberger, E. Gavartin, O. Arcizet +5 more

We report a room-temperature measurement of nanomechanical motion with an imprecision below the standard quantum limit (SQL), using cavity-enhanced optical near fields. Fundamental thermodynamical cavity frequency fluctuation limits the total imprecision to $3 \mathrm{dB}$ below the SQL at room temperature [corresponding to $(530 \mathrm{am}/\sqrt{\mathrm{Hz}}){}^{2}$ in absolute units] and is expected to reduce to negligible values at moderate cryogenic temperatures. Coupling strengths exceeding those required to reach the SQL by more than two orders of magnitude are achieved, allowing a shot-noise limited imprecision more than $10 \mathrm{dB}$ below the SQL. The transducer, thus, in principle, allows access to the quantum backaction dominated regime, a prerequisite for exploring quantum backaction, measurement-induced squeezing, and obtaining sub-SQL sensitivity using backaction evading techniques.

arXiv:1003.3752•Physical Review A•Dec 29, 2010•164 citations

Quantum Measurement of a Mechanical Resonator at and Below the Standard Quantum Limit

Massimiliano Rossi, David L. Mason, Junxin Chen +2 more

We measure mechanical displacements within 35% of the Heisenberg limit. By exploiting quantum correlations in an optomechanical system, we achieve for the first time a total sensitivity below the standard quantum limit by 1.5 dB. © 2019 The Author(s)

Conference on Lasers and Electro-Optics•May 1, 2019•0 citations

Measuring nanomechanical motion with an imprecision below that at the standard quantum limit

G. Anetsberger, P. Verlot, E. Gavartin +6 more

Using optical readout, we demonstrate for the first time sub-SQL imprecision for nanomechanical motion at room temperature.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2011•7 citations

Entanglement-enhanced optical magnetometry beyond the standard quantum limit

Jun Jia, Túlio Brito Brasil, Maimouna Bocoum +6 more

Optical atomic magnetometry is a powerful tool for continuous sensing applications, yet, in the absence of quantum correlations, its sensitivity is limited by the standard quantum limit (SQL) stemming from a trade-off between optical probe imprecision and quantum measurement backaction. Beyond-SQL sensitivity requires quantum correlations that modify these measurement noise sources. Here we demonstrate such sensitivity by using entangled state of the probe light and by engineering correlations between measurement imprecision and backaction. Having first explored SQL in a broad range of frequencies, we demonstrate overcoming the limit by combining variational readout with coupling the magnetometer to one mode of a bipartite entangled light state and conditioning the results on the other entangled mode. Tuning the detected light quadratures and combining the signals from the two measurement channels, we achieve sensitivity beyond the SQL in a broad range of acoustic frequencies which has so far remained inaccessible to quantum-noise-limited optical magnetometry.

quant-pharXiv:2608.06815•Aug 10, 2026•0 citations

Surpassing the Standard Quantum Limit Using an Optical Spring

T. J. Cullen, Ronald Pagano, Scott Aronson +9 more

Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements imposes a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a backaction evading measurement technique, reduce thermal noise to below the level of backaction, and exploit cancellations of any excess noise contributions at the detector. Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL sensitivity nearly two times better than previous measurements, and with an architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. We measure a total sensitivity below the SQL by 2.8 dB, corresponding to a reduction in the noise power by 72±5.1% below the quantum limit. Through the use of a detuned cavity and the optical spring effect, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the Universe.

arXiv:2210.12222•Physical Review Letters•Sep 13, 2024•6 citations
Interferometrie techniques to measure mechanical displacement are subject to constraints ultimately governed by quantum mechanics. In a "standard" measurement of a mechanically induced optical phase shift, there exists a trade-off between measurement imprecision and motion disturbance, known as standard quantum limit (SQL) [1]. For a mechanical resonator with susceptibility χm(Ω), this limit is SSQL(Ω) = ħ|χm(Ω)| (ħ reduced Planck constant), at any frequency Ω. In the last half-century, a number of systems, including advanced LIGO and ultracold atoms have progressed towards this limit, but excess sources of noise have yet prevented fully reaching the SQL. Here, we show measurements of an ultracoherent mechanical resonator performed at the SQL within 33% [2] and, for the first time, below the SQL by 1.5 dB[3]. The latter has been possible by a non-standard measurement scheme that explois quantum correlations between optical quadratures induced in the optomechanical device.
We report a room-temperature measurement of nanomechanical motion with an imprecision below the standard quantum limit (SQL), using cavity-enhanced optical near fields. Fundamental thermodynamical cavity frequency fluctuation limits the total imprecision to 3dB3 \mathrm{dB}3dB below the SQL at room temperature [corresponding to (530am/Hz)2(530 \mathrm{am}/\sqrt{\mathrm{Hz}}){}^{2}(530am/Hz​)2 in absolute units] and is expected to reduce to negligible values at moderate cryogenic temperatures. Coupling strengths exceeding those required to reach the SQL by more than two orders of magnitude are achieved, allowing a shot-noise limited imprecision more than 10dB10 \mathrm{dB}10dB below the SQL. The transducer, thus, in principle, allows access to the quantum backaction dominated regime, a prerequisite for exploring quantum backaction, measurement-induced squeezing, and obtaining sub-SQL sensitivity using backaction evading techniques.
Optical atomic magnetometry is a powerful tool for continuous sensing applications, yet, in the absence of quantum correlations, its sensitivity is limited by the standard quantum limit (SQL) stemming from a trade-off between optical probe imprecision and quantum measurement backaction. Beyond-SQL sensitivity requires quantum correlations that modify these measurement noise sources. Here we demonstrate such sensitivity by using entangled state of the probe light and by engineering correlations between measurement imprecision and backaction. Having first explored SQL in a broad range of frequencies, we demonstrate overcoming the limit by combining variational readout with coupling the magnetometer to one mode of a bipartite entangled light state and conditioning the results on the other entangled mode. Tuning the detected light quadratures and combining the signals from the two measurement channels, we achieve sensitivity beyond the SQL in a broad range of acoustic frequencies which has so far remained inaccessible to quantum-noise-limited optical magnetometry.
Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements imposes a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a backaction evading measurement technique, reduce thermal noise to below the level of backaction, and exploit cancellations of any excess noise contributions at the detector. Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL sensitivity nearly two times better than previous measurements, and with an architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. We measure a total sensitivity below the SQL by 2.8 dB, corresponding to a reduction in the noise power by 72±5.1% below the quantum limit. Through the use of a detuned cavity and the optical spring effect, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the Universe.