Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Measuring nanomechanical motion with an imprecision below that at the standard quantum limit

G. Anetsberger, P. Verlot, E. Gavartin, O. Arcizet, Quirin P. Unterreithmeier, Eva Maria Weig, M. L. Gorodetsky, J. P. Kotthaus, Tobias Jan Kippenberg

Published May 1, 2011• 7 citations
Publisher

Abstract

Using optical readout, we demonstrate for the first time sub-SQL imprecision for nanomechanical motion at room temperature.
DOI
10.1109/cleoe.2011.5943378

Related papers

Measuring nanomechanical motion with an imprecision below the standard quantum limit

G. Anetsberger, E. Gavartin, O. Arcizet +5 more

We report a room-temperature measurement of nanomechanical motion with an imprecision below the standard quantum limit (SQL), using cavity-enhanced optical near fields. Fundamental thermodynamical cavity frequency fluctuation limits the total imprecision to $3 \mathrm{dB}$ below the SQL at room temperature [corresponding to $(530 \mathrm{am}/\sqrt{\mathrm{Hz}}){}^{2}$ in absolute units] and is expected to reduce to negligible values at moderate cryogenic temperatures. Coupling strengths exceeding those required to reach the SQL by more than two orders of magnitude are achieved, allowing a shot-noise limited imprecision more than $10 \mathrm{dB}$ below the SQL. The transducer, thus, in principle, allows access to the quantum backaction dominated regime, a prerequisite for exploring quantum backaction, measurement-induced squeezing, and obtaining sub-SQL sensitivity using backaction evading techniques.

arXiv:1003.3752•Physical Review A•Dec 29, 2010•164 citations

Nanomechanical motion measured with an imprecision below that at the standard quantum limit

John D. Teufel, Tobias Donner, Manuel A. Castellanos-Beltran +2 more

arXiv:0906.1212•Nature Nanotechnology•Nov 1, 2009•557 citations

Measuring Motion Below the Standard Quantum Limit by Strong Optomechanical Quantum Correlations

Junxin Chen, David Mason, Massimiliano Rossi +2 more

In interferometric displacement and force measurement, the tradeoff between imprecision noise and quantum backaction sets the standard quantum limit (SQL). By exploiting quantum correlations in an optomechanical system, we demonstrate the first sub-SQL interferometric measurement.

Quantum Information and Measurement (QIM)•Jan 1, 2019•0 citations

Entanglement-enhanced optical magnetometry beyond the standard quantum limit

Jun Jia, Túlio Brito Brasil, Maimouna Bocoum +6 more

Optical atomic magnetometry is a powerful tool for continuous sensing applications, yet, in the absence of quantum correlations, its sensitivity is limited by the standard quantum limit (SQL) stemming from a trade-off between optical probe imprecision and quantum measurement backaction. Beyond-SQL sensitivity requires quantum correlations that modify these measurement noise sources. Here we demonstrate such sensitivity by using entangled state of the probe light and by engineering correlations between measurement imprecision and backaction. Having first explored SQL in a broad range of frequencies, we demonstrate overcoming the limit by combining variational readout with coupling the magnetometer to one mode of a bipartite entangled light state and conditioning the results on the other entangled mode. Tuning the detected light quadratures and combining the signals from the two measurement channels, we achieve sensitivity beyond the SQL in a broad range of acoustic frequencies which has so far remained inaccessible to quantum-noise-limited optical magnetometry.

quant-pharXiv:2608.06815•Aug 10, 2026•0 citations

On the quantum limit for resolution in force measurement using an optical displacement transducer

Sergey P. Vyatchanin, Elena A. Zubova, Andrey B. Matsko

Optics Communications•Jul 1, 1994•21 citations

Interferometer readout noise below the standard quantum limit of a membrane

T. Westphal, D. Friedrich, H. Kaufer +7 more

Here we report on the realization of a Michelson-Sagnac interferometer whose purpose is the precise characterization of the motion of, i.e., membranes showing significant light transmission. Our interferometer has a readout noise spectral density (imprecision) of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}\phantom{\rule{0.16em}{0ex}}\mathrm{m}/\sqrt{\mathrm{Hz}}$ at frequencies around the fundamental resonance of a SiN${}_{\mathrm{x}}$ membrane at about 100 kHz, without using optical cavities. The readout noise demonstrated is more than 16 dB below the peak value of the membrane's standard quantum limit (SQL). This margin is significantly bigger than those of previous works with nanowires [Teufel et al., Nature Nano. 4, 820 (2009); Anetsberger et al., Nature Phys. 5, 909 (2009)]. We discuss the meaning of the SQL for force measurements and its relation to the readout performance and emphasize that neither our nor previous experiments achieved a total noise spectral density as low as the SQL due to thermal noise.

Physical Review A•Jun 6, 2012•30 citations
We report a room-temperature measurement of nanomechanical motion with an imprecision below the standard quantum limit (SQL), using cavity-enhanced optical near fields. Fundamental thermodynamical cavity frequency fluctuation limits the total imprecision to 3dB3 \mathrm{dB}3dB below the SQL at room temperature [corresponding to (530am/Hz)2(530 \mathrm{am}/\sqrt{\mathrm{Hz}}){}^{2}(530am/Hz​)2 in absolute units] and is expected to reduce to negligible values at moderate cryogenic temperatures. Coupling strengths exceeding those required to reach the SQL by more than two orders of magnitude are achieved, allowing a shot-noise limited imprecision more than 10dB10 \mathrm{dB}10dB below the SQL. The transducer, thus, in principle, allows access to the quantum backaction dominated regime, a prerequisite for exploring quantum backaction, measurement-induced squeezing, and obtaining sub-SQL sensitivity using backaction evading techniques.
Optical atomic magnetometry is a powerful tool for continuous sensing applications, yet, in the absence of quantum correlations, its sensitivity is limited by the standard quantum limit (SQL) stemming from a trade-off between optical probe imprecision and quantum measurement backaction. Beyond-SQL sensitivity requires quantum correlations that modify these measurement noise sources. Here we demonstrate such sensitivity by using entangled state of the probe light and by engineering correlations between measurement imprecision and backaction. Having first explored SQL in a broad range of frequencies, we demonstrate overcoming the limit by combining variational readout with coupling the magnetometer to one mode of a bipartite entangled light state and conditioning the results on the other entangled mode. Tuning the detected light quadratures and combining the signals from the two measurement channels, we achieve sensitivity beyond the SQL in a broad range of acoustic frequencies which has so far remained inaccessible to quantum-noise-limited optical magnetometry.
Here we report on the realization of a Michelson-Sagnac interferometer whose purpose is the precise characterization of the motion of, i.e., membranes showing significant light transmission. Our interferometer has a readout noise spectral density (imprecision) of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}\phantom{\rule{0.16em}{0ex}}\mathrm{m}/\sqrt{\mathrm{Hz}}$ at frequencies around the fundamental resonance of a SiNx{}_{\mathrm{x}}x​ membrane at about 100 kHz, without using optical cavities. The readout noise demonstrated is more than 16 dB below the peak value of the membrane's standard quantum limit (SQL). This margin is significantly bigger than those of previous works with nanowires [Teufel et al., Nature Nano. 4, 820 (2009); Anetsberger et al., Nature Phys. 5, 909 (2009)]. We discuss the meaning of the SQL for force measurements and its relation to the readout performance and emphasize that neither our nor previous experiments achieved a total noise spectral density as low as the SQL due to thermal noise.