IEICE Technical Report; IEICE Tech. Rep.

Development of superconducting image sensors in the submillimeter wavelength

Yutaro Sekímoto

Published Apr 15, 2015• 0 citations
OpenAlex

Related papers

Development of superconducting image sensors in the submillimeter wavelength

裕太郎 関本

IEICE technical report. Speech•Apr 22, 2015•0 citations

Superconducting Sensors for Submillimeter Heterodyne Receiver Systems

Henry George LeDuc, B. Bumble, Koko G. Megerian +1 more

•Jan 1, 1996•0 citations

Recent Progress of a Submillimeter Superconducting Integrated Receiver for Imaging Applications

S. V. Shitov, V. P. Koshelets, A. M. Baryshev +4 more

•Aug 1, 1997•0 citations

Background Limited Quantum Superconducting Detector for Submillimeter Wavelengths

Gregory N Gol'tsman, Alexei D. Semenov, Konstantin Smirnov +1 more

Softwaretechnik-Trends•Dec 1, 2001•1 citation

Superconducting antenna-coupled YBCO bolometers at submillimeter wavelengths

A. Scheuring, Petra Probst, C. Dischke +2 more

•Jan 1, 2010•0 citations

Superconducting integrated receiver as 400-600 GHz tester for coolable devices

S. V. Shitov, M. Levitchev, A. V. Veretennikov +7 more

A laboratory-purpose submillimeter wavelength receiver is developed and tested. The device can in situ detect the spectrum of an rf source working below 100 K within the frequency range 400-600 GHz. A sample is placed close to the receiver sensor; both are in vacuum inside the probe stick and cooled by liquid helium in the standard transport dewar. The quasioptical sensor design is based on the superconducting integrated receiver chip; its noise temperature below 300 K was measured at /spl ap/500 GHz with a variable-temperature black body. The output level of the tester is suitable for the direct readout by a spectrum analyzer. Details of the design and main test data are reported.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•6 citations
A laboratory-purpose submillimeter wavelength receiver is developed and tested. The device can in situ detect the spectrum of an rf source working below 100 K within the frequency range 400-600 GHz. A sample is placed close to the receiver sensor; both are in vacuum inside the probe stick and cooled by liquid helium in the standard transport dewar. The quasioptical sensor design is based on the superconducting integrated receiver chip; its noise temperature below 300 K was measured at /spl ap/500 GHz with a variable-temperature black body. The output level of the tester is suitable for the direct readout by a spectrum analyzer. Details of the design and main test data are reported.