Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEICE technical report. Speech

Development of superconducting image sensors in the submillimeter wavelength

裕太郎 関本

Published Apr 22, 2015• 0 citations
OpenAlex

Related papers

Development of superconducting image sensors in the submillimeter wavelength

Yutaro Sekímoto

IEICE Technical Report; IEICE Tech. Rep.•Apr 15, 2015•0 citations

Superconducting Sensors for Submillimeter Heterodyne Receiver Systems

Henry George LeDuc, B. Bumble, Koko G. Megerian +1 more

•Jan 1, 1996•0 citations

Recent Progress of a Submillimeter Superconducting Integrated Receiver for Imaging Applications

S. V. Shitov, V. P. Koshelets, A. M. Baryshev +4 more

•Aug 1, 1997•0 citations

Background Limited Quantum Superconducting Detector for Submillimeter Wavelengths

Gregory N Gol'tsman, Alexei D. Semenov, Konstantin Smirnov +1 more

Softwaretechnik-Trends•Dec 1, 2001•1 citation

Superconducting antenna-coupled YBCO bolometers at submillimeter wavelengths

A. Scheuring, Petra Probst, C. Dischke +2 more

•Jan 1, 2010•0 citations

Superconducting integrated receiver as 400-600 GHz tester for coolable devices

S. V. Shitov, M. Levitchev, A. V. Veretennikov +7 more

A laboratory-purpose submillimeter wavelength receiver is developed and tested. The device can in situ detect the spectrum of an rf source working below 100 K within the frequency range 400-600 GHz. A sample is placed close to the receiver sensor; both are in vacuum inside the probe stick and cooled by liquid helium in the standard transport dewar. The quasioptical sensor design is based on the superconducting integrated receiver chip; its noise temperature below 300 K was measured at /spl ap/500 GHz with a variable-temperature black body. The output level of the tester is suitable for the direct readout by a spectrum analyzer. Details of the design and main test data are reported.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•6 citations
A laboratory-purpose submillimeter wavelength receiver is developed and tested. The device can in situ detect the spectrum of an rf source working below 100 K within the frequency range 400-600 GHz. A sample is placed close to the receiver sensor; both are in vacuum inside the probe stick and cooled by liquid helium in the standard transport dewar. The quasioptical sensor design is based on the superconducting integrated receiver chip; its noise temperature below 300 K was measured at /spl ap/500 GHz with a variable-temperature black body. The output level of the tester is suitable for the direct readout by a spectrum analyzer. Details of the design and main test data are reported.