Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical clocks and fiber links

Jérôme Lodewyck

Published Mar 18, 2017• 0 citations
OpenAlex

Abstract

Optical clocks are now the most stable and accurate frequency standards, withperformances in the low 10 −18 , outperforming by two orders of magnitude thebest microwave primary standards based on cesium. This opens the question of apossible redefinition of the SI (Système International) second with an opticaltransition. However, several operational steps have to be demonstrated beforesuch a redefinition can be effective: reliable and interconnected clocks arenecessary to realize the definition. Here, we report on several experimentaladvents in this direction, including the remote comparison of optical latticeclocks via phase compensated optical fiber links between different metrologyinstitutes across Europe.

Related papers

When should we change the definition of the second?

Patrick Robert Gill

The microwave caesium (Cs) atomic clock has formed an enduring basis for the second in the International System of Units (SI) over the last few decades. The advent of laser cooling has underpinned the development of cold Cs fountain clocks, which now achieve frequency uncertainties of approximately 5×10(-16). Since 2000, optical atomic clock research has quickened considerably, and now challenges Cs fountain clock performance. This has been suitably shown by recent results for the aluminium Al(+) quantum logic clock, where a fractional frequency inaccuracy below 10(-17) has been reported. A number of optical clock systems now achieve or exceed the performance of the Cs fountain primary standards used to realize the SI second, raising the issues of whether, how and when to redefine it. Optical clocks comprise frequency-stabilized lasers probing very weak absorptions either in a single cold ion confined in an electromagnetic trap or in an ensemble of cold atoms trapped within an optical lattice. In both cases, different species are under consideration as possible redefinition candidates. In this paper, I consider options for redefinition, contrast the performance of various trapped ion and optical lattice systems, and point to potential limiting environmental factors, such as magnetic, electric and light fields, collisions and gravity, together with the challenge of making remote comparisons of optical frequencies between standards laboratories worldwide.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Sep 19, 2011•102 citations

Study of optical frequency transfer via fiber

Jie Liu, Jing Gao, Guanjun Xu +6 more

Optical clocks are considered as promising candidates for redefining the second in the International System of Units. Compared with microwave clocks, optical clocks are powerful tools for the fundamental research such as the constancy of the fundamental constants, the validity of Einstein’s theory of general relativity, and the predictions of quantum electrodynamics. Recently two research groups have demonstrated the optical clocks with an unprecedented precision level of 10-18, which is two orders better than the present primary frequency standard. Using two Sr optical clocks and three Cs fountain clocks, SYRTE group has demonstrated the definition of second with optical clocks.#br#For redefining the second with optical clocks in the future, the optical clocks from the remote laboratories should have a high precision and the frequency of the optical clocks need to be transferred over a long distance, with extremely high precision. Unfortunately the conventional means of frequency transfer such as two-way satellite time and frequency transfer can reach a 10-16 level in one day which is far below the requirement for an optical clocks. Various methods have been developed to transfer optical frequency signal via optical fibers. Especially a research group from Germany has achieved a frequency transfer stability of 10-19 level in hundreds of seconds with a fiber length of 1840 km.#br#We demonstrate the recent development of optical frequency transfer over a 70-km fiber spool at National Time Service Center. The measurement shows that the compensation for the fiber noise is close to the limitation induced by the fiber delay for the Fourier frequency from 1 Hz to 250 Hz. The transfer stability (Allan deviation) of the fiber link is 1.2×10-15 in 1 s averaging time, and 1.4×10-18 in 10000 s. A preliminary test of the optical frequency transfer over a 100-km spooled fiber is achieved with a stability of roughly one order worse than the 71 km result, 5×10-15 in 1 s.#br#We demonstrate a new scheme of remote compensation for optical frequency transfer via fibers against conventional local compensation method. This new scheme has the advantage of great simplification of the local site, which can find applications in massive extension of star network. The key feature is that we transfer the mixture of the round-trip signal and local reference to the remote user’s end via an auxiliary fiber. At remote site, the fiber noise is measured and compensated by AOM2 accordingly.#br#Transfer stabilities of 13×10-15 in 1 s averaging time and 4.8×10-18 in 10000 s are achieved with the remote fiber noise compensation via a 25 km fiber spool. The demonstrated transfer stability is comparable to that obtained by the local fiber noise compensation method.#br#The future star fiber network of optical frequency transfer can benefit from this method, because the simpler local setup is required and even can be shared in the central site for multitudinous remote users.

Acta Physica Sinica•Jan 1, 2015•8 citations

A clock network for geodesy and fundamental science

Christian Lisdat, Gesine Grosche, Nicolas Quintin +32 more

Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.

arXiv:1511.07735•Nature Communications•Aug 9, 2016•460 citations

Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks

Boulder Atomic Clock Optical Network, Collaboration, : +35 more

Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.

arXiv:2005.14694•May 29, 2020•13 citations

All-optical link for direct comparison of distant optical clocks

Miho Fujieda, Motohiro Kumagai, Shigeo Nagano +3 more

We developed an all-optical link system for making remote comparisons of two distant ultra-stable optical clocks. An optical carrier transfer system based on a fiber interferometer was employed to compensate the phase noise accumulated during the propagation through a fiber link. Transfer stabilities of 2 × 10(-15) at 1 second and 4 × 10(-18) at 1000 seconds were achieved in a 90-km link. An active polarization control system was additionally introduced to maintain the transmitted light in an adequate polarization, and consequently, a stable and reliable comparison was accomplished. The instabilities of the all-optical link system, including those of the erbium doped fiber amplifiers (EDFAs) which are free from phase-noise compensation, were below 2 × 10(-15) at 1 second and 7 × 10(-17) at 1000 seconds. The system was available for the direct comparison of two distant (87)Sr lattice clocks via an urban fiber link of 60 km. This technique will be essential for the measuring the reproducibility of optical frequency standards.

arXiv:1108.2775•Optics Express•Aug 11, 2011•93 citations

Optical fiber link for ultra-stable frequency dissemination and atomic clock comparisons

Anne Amy‐Klein, Nicolas Quintin, N. Chiodo +42 more

The transfer of ultra-stable frequencies between distant laboratories is required by many applications from fundamental metrology to high-precision measurements. For that purpose, optical fibre links have been intensively studied over the last decade. They have demonstrated impressive results far beyond the GPS capabilities on distances up to 2000 km, thanks to an active compensation of the fiber propagation noise.Up to now, optical links has been mainly implemented between two labs, when future applications will require the development of metrological fiber networks. Towards this goal, we have developed a few techniques which allow us to distribute the ultrastable optical signal to many users simultaneously. We have designed repeater laser stations, which can be used to build a cascaded link or to distribute the ultrastable signal among two optical links [1]. These stations allow us also to compare the output end signals of two optical links. These versatile stations will be a key-component of the national metrological network currently being developed in France within the Refimeve+ project. To complete the network, we have demonstrated the extraction of the ultrastable signal from a main link and its seeding to a secondary link [2].Optical links are already been successfully used for clocks comparison. Recently we were able to compare the atomic clocks of the French and German National Metrology Institutes through two connected optical links of total length 1415-km [3]. We found that the two fully independent Sr lattice optical clocks at the two sites agreed to better than 5x10-17 limited only by the clocks uncertainties. A fractional statistical uncertainty of 3x10-17 was reached after only 1000 s averaging time, which is 10 times better, and more than four orders of magnitude faster than with any other existing frequency transfer method. The atomic fountain primary frequency standards from the two institutes were also compared and they were found to agree well within their combined uncertainties of a few 10-16 [4].

•Jan 1, 2017•0 citations
Optical clocks are now the most stable and accurate frequency standards, withperformances in the low 10 −18 , outperforming by two orders of magnitude thebest microwave primary standards based on cesium. This opens the question of apossible redefinition of the SI (Système International) second with an opticaltransition. However, several operational steps have to be demonstrated beforesuch a redefinition can be effective: reliable and interconnected clocks arenecessary to realize the definition. Here, we report on several experimentaladvents in this direction, including the remote comparison of optical latticeclocks via phase compensated optical fiber links between different metrologyinstitutes across Europe.
The microwave caesium (Cs) atomic clock has formed an enduring basis for the second in the International System of Units (SI) over the last few decades. The advent of laser cooling has underpinned the development of cold Cs fountain clocks, which now achieve frequency uncertainties of approximately 5×10(-16). Since 2000, optical atomic clock research has quickened considerably, and now challenges Cs fountain clock performance. This has been suitably shown by recent results for the aluminium Al(+) quantum logic clock, where a fractional frequency inaccuracy below 10(-17) has been reported. A number of optical clock systems now achieve or exceed the performance of the Cs fountain primary standards used to realize the SI second, raising the issues of whether, how and when to redefine it. Optical clocks comprise frequency-stabilized lasers probing very weak absorptions either in a single cold ion confined in an electromagnetic trap or in an ensemble of cold atoms trapped within an optical lattice. In both cases, different species are under consideration as possible redefinition candidates. In this paper, I consider options for redefinition, contrast the performance of various trapped ion and optical lattice systems, and point to potential limiting environmental factors, such as magnetic, electric and light fields, collisions and gravity, together with the challenge of making remote comparisons of optical frequencies between standards laboratories worldwide.
Optical clocks are considered as promising candidates for redefining the second in the International System of Units. Compared with microwave clocks, optical clocks are powerful tools for the fundamental research such as the constancy of the fundamental constants, the validity of Einstein’s theory of general relativity, and the predictions of quantum electrodynamics. Recently two research groups have demonstrated the optical clocks with an unprecedented precision level of 10-18, which is two orders better than the present primary frequency standard. Using two Sr optical clocks and three Cs fountain clocks, SYRTE group has demonstrated the definition of second with optical clocks.#br#For redefining the second with optical clocks in the future, the optical clocks from the remote laboratories should have a high precision and the frequency of the optical clocks need to be transferred over a long distance, with extremely high precision. Unfortunately the conventional means of frequency transfer such as two-way satellite time and frequency transfer can reach a 10-16 level in one day which is far below the requirement for an optical clocks. Various methods have been developed to transfer optical frequency signal via optical fibers. Especially a research group from Germany has achieved a frequency transfer stability of 10-19 level in hundreds of seconds with a fiber length of 1840 km.#br#We demonstrate the recent development of optical frequency transfer over a 70-km fiber spool at National Time Service Center. The measurement shows that the compensation for the fiber noise is close to the limitation induced by the fiber delay for the Fourier frequency from 1 Hz to 250 Hz. The transfer stability (Allan deviation) of the fiber link is 1.2×10-15 in 1 s averaging time, and 1.4×10-18 in 10000 s. A preliminary test of the optical frequency transfer over a 100-km spooled fiber is achieved with a stability of roughly one order worse than the 71 km result, 5×10-15 in 1 s.#br#We demonstrate a new scheme of remote compensation for optical frequency transfer via fibers against conventional local compensation method. This new scheme has the advantage of great simplification of the local site, which can find applications in massive extension of star network. The key feature is that we transfer the mixture of the round-trip signal and local reference to the remote user’s end via an auxiliary fiber. At remote site, the fiber noise is measured and compensated by AOM2 accordingly.#br#Transfer stabilities of 13×10-15 in 1 s averaging time and 4.8×10-18 in 10000 s are achieved with the remote fiber noise compensation via a 25 km fiber spool. The demonstrated transfer stability is comparable to that obtained by the local fiber noise compensation method.#br#The future star fiber network of optical frequency transfer can benefit from this method, because the simpler local setup is required and even can be shared in the central site for multitudinous remote users.
Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the 27^{27}27Al+^++, 171^{171}171Yb and 87^{87}87Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between 6×10−186\times10^{-18}6×10−18 and 8×10−188\times10^{-18}8×10−18, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.
We developed an all-optical link system for making remote comparisons of two distant ultra-stable optical clocks. An optical carrier transfer system based on a fiber interferometer was employed to compensate the phase noise accumulated during the propagation through a fiber link. Transfer stabilities of 2 × 10(-15) at 1 second and 4 × 10(-18) at 1000 seconds were achieved in a 90-km link. An active polarization control system was additionally introduced to maintain the transmitted light in an adequate polarization, and consequently, a stable and reliable comparison was accomplished. The instabilities of the all-optical link system, including those of the erbium doped fiber amplifiers (EDFAs) which are free from phase-noise compensation, were below 2 × 10(-15) at 1 second and 7 × 10(-17) at 1000 seconds. The system was available for the direct comparison of two distant (87)Sr lattice clocks via an urban fiber link of 60 km. This technique will be essential for the measuring the reproducibility of optical frequency standards.
The transfer of ultra-stable frequencies between distant laboratories is required by many applications from fundamental metrology to high-precision measurements. For that purpose, optical fibre links have been intensively studied over the last decade. They have demonstrated impressive results far beyond the GPS capabilities on distances up to 2000 km, thanks to an active compensation of the fiber propagation noise.Up to now, optical links has been mainly implemented between two labs, when future applications will require the development of metrological fiber networks. Towards this goal, we have developed a few techniques which allow us to distribute the ultrastable optical signal to many users simultaneously. We have designed repeater laser stations, which can be used to build a cascaded link or to distribute the ultrastable signal among two optical links [1]. These stations allow us also to compare the output end signals of two optical links. These versatile stations will be a key-component of the national metrological network currently being developed in France within the Refimeve+ project. To complete the network, we have demonstrated the extraction of the ultrastable signal from a main link and its seeding to a secondary link [2].Optical links are already been successfully used for clocks comparison. Recently we were able to compare the atomic clocks of the French and German National Metrology Institutes through two connected optical links of total length 1415-km [3]. We found that the two fully independent Sr lattice optical clocks at the two sites agreed to better than 5x10-17 limited only by the clocks uncertainties. A fractional statistical uncertainty of 3x10-17 was reached after only 1000 s averaging time, which is 10 times better, and more than four orders of magnitude faster than with any other existing frequency transfer method. The atomic fountain primary frequency standards from the two institutes were also compared and they were found to agree well within their combined uncertainties of a few 10-16 [4].