Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

Direct generation of continuous-wave optical squeezing at 532 nm via degenerated parametric down-conversion

Guozhu Chen, Qu Liu, Yong Shen, Hongxin Zou

Published Dec 7, 2018• 2 citations
Publisher
DOI
10.1016/j.optcom.2018.11.082

Related papers

Bright squeezed-light generation by a continuous-wave semimonolithic parametric amplifier

K. Schneider, Robert Bruckmeier, Hauke Hansen +2 more

Continuous-wave amplitude-squeezed light at 1064 nm has been generated with excellent long-term stability by use of a dual-port type I degenerate optical parametric amplifier pumped by a frequency-doubled Nd:YAG laser. A seed wave at 1064 nm is resonantly injected through the low-transmission cavity port, whereas the parametrically deamplified and squeezed output wave is extracted from the high-transmission port. Amplitude noise reduction of as much as 4.3 dB is observed directly at an output power of 0.15 mW. Stable noise suppression exceeding 3.8 dB is obtained for several hours by phase locking of the pump wave. The longterm stability and simplicity make this device suitable for sub-shot-noise metrology.

Optics Letters•Sep 1, 1996•64 citations

Continuous-Wave Squeezed-Light Generation Using a Triply Resonant Optical Parametric Oscillator

Katsuyuki Kasai

Springer eBooks•Jan 1, 1995•1 citation

Two-mode squeezing in a coherently driven degenerate parametric down conversion

Sintayehu Tesfa

The European Physical Journal D•Oct 18, 2007•15 citations

Generation of Quantum Correlated Optical - Terahertz Photon Pairs and Calibration of Nonlinear-Optical Detectors via Parametric Down-Conversion

Vladimir V. Kornienko, Kirill A. Kuznetsov, A.A. Leontyev +2 more

Quantum effect of parametric down-conversion is studied in a strongly frequency non-degenerate regime, when pairs of correlated optical and terahertz photons are generated along with parametric amplification and frequency conversion of thermal fluctuations and external radiation at terahertz frequencies. The terahertz photon fluxes emitted due to parametric down-conversion are registered. Direct incoherent nonlinear-optical detection is demonstrated for continuous wave sources at 0.2-0.4 THz.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2018•0 citations

Generation of bright squeezed light at 1.5 m telecommunication band and its Wigner function reconstruction

孙志妮 SUN Zhi-ni, Feng Jin-Xia, Wan Zhen-Ju +1 more

The squeezed light at 1.5 m telecommunication band has been considered as an important resource of continuous variable (CV) practical fiber-based quantum information research because it is the lowest loss in fiber. A bright phase quadrature squeezed light for continuous variable at 1.5 m is demonstrated from a semi-monolithic degenerate optical parametric amplifier (DOPA) based on a periodically poled KTiOPO4 (PPKTP) crystal. The laser source is a continuous wave (CW) single-frequency fiber laser at 1.5 m, which is sent through a ring mode cleaner (MC) as a preliminary spatial and noise filter. And then the main portion of the output from the MC is used for external-enhanced second harmonic generation to obtain a CW single-frequency low noise laser at 780 nm that acts as the pump of the DOPA. The residual light of the output from the MC at 1.5 m is used as the injected signal light of the DOPA and the local oscillator (LO) of a balanced homodyne detector (BHD) system. The DOPA is built by using a type-I PPKTP crystal and a piezo-actuated output coupler and works in double-resonance case with a threshold power of 230 mW. When the DOPA is operating in the state of amplification, the output down-conversion field should be a bright phase quadrature squeezed light, where the relative phase between the pump and the injected signal is locked to 0. A 4.7 dB bright phase quadrature squeezed light is measured by the BHD system with the pump light of 110 mW and the injected signal of 3 mW, where the relative phase between the down-conversion field and the LO is locked to 0. Our measurement is limited by the optical losses and the detection efficiency. We have taken into account the detection efficiency of 86.6%, and the actual squeezing of the squeezed light being 6.3 dB. Moreover, because it is so crucial a process for CV quantum information system that the transmission and evolution of the CV squeezed states in the fiber may reappear in all information of the quantum states in the phase space, then the bright squeezed light is detected by a BHD system in the time domain, and its Wigner quasi-probability distribution function can be reconstructed by using a quantum tomographic technique. Furthermore, the bright squeezed state at 1.5 m is an ideal source for fiber-based long-distance quantum information because of its stability and bright mean field.

Acta Physica Sinica•Jan 1, 2016•4 citations

Generation of polarization squeezed light with an optical parametric amplifier at 795 nm

Yashuai Han, Xin Wen, Jinyu Liu +2 more

arXiv:1705.08696•Optics Communications•Feb 7, 2018•9 citations
Continuous-wave amplitude-squeezed light at 1064 nm has been generated with excellent long-term stability by use of a dual-port type I degenerate optical parametric amplifier pumped by a frequency-doubled Nd:YAG laser. A seed wave at 1064 nm is resonantly injected through the low-transmission cavity port, whereas the parametrically deamplified and squeezed output wave is extracted from the high-transmission port. Amplitude noise reduction of as much as 4.3 dB is observed directly at an output power of 0.15 mW. Stable noise suppression exceeding 3.8 dB is obtained for several hours by phase locking of the pump wave. The longterm stability and simplicity make this device suitable for sub-shot-noise metrology.
The squeezed light at 1.5 m telecommunication band has been considered as an important resource of continuous variable (CV) practical fiber-based quantum information research because it is the lowest loss in fiber. A bright phase quadrature squeezed light for continuous variable at 1.5 m is demonstrated from a semi-monolithic degenerate optical parametric amplifier (DOPA) based on a periodically poled KTiOPO4 (PPKTP) crystal. The laser source is a continuous wave (CW) single-frequency fiber laser at 1.5 m, which is sent through a ring mode cleaner (MC) as a preliminary spatial and noise filter. And then the main portion of the output from the MC is used for external-enhanced second harmonic generation to obtain a CW single-frequency low noise laser at 780 nm that acts as the pump of the DOPA. The residual light of the output from the MC at 1.5 m is used as the injected signal light of the DOPA and the local oscillator (LO) of a balanced homodyne detector (BHD) system. The DOPA is built by using a type-I PPKTP crystal and a piezo-actuated output coupler and works in double-resonance case with a threshold power of 230 mW. When the DOPA is operating in the state of amplification, the output down-conversion field should be a bright phase quadrature squeezed light, where the relative phase between the pump and the injected signal is locked to 0. A 4.7 dB bright phase quadrature squeezed light is measured by the BHD system with the pump light of 110 mW and the injected signal of 3 mW, where the relative phase between the down-conversion field and the LO is locked to 0. Our measurement is limited by the optical losses and the detection efficiency. We have taken into account the detection efficiency of 86.6%, and the actual squeezing of the squeezed light being 6.3 dB. Moreover, because it is so crucial a process for CV quantum information system that the transmission and evolution of the CV squeezed states in the fiber may reappear in all information of the quantum states in the phase space, then the bright squeezed light is detected by a BHD system in the time domain, and its Wigner quasi-probability distribution function can be reconstructed by using a quantum tomographic technique. Furthermore, the bright squeezed state at 1.5 m is an ideal source for fiber-based long-distance quantum information because of its stability and bright mean field.