Key engineering materials

The Unique Property in Magnetic Noise of Spin Modulated Atomic Magnetometer

Xiaofei Wang, Ji Min Li

Published Nov 1, 2018• 0 citations
Publisher

Abstract

This paper presents a spin modulated atomic magnetometer, different from other kinds of atomic magnetometers, the conversion coefficient between the polarization signal and the magnetic field to be measured is independent of the transverse relaxation time, which means that the higher sensitivity can be achieved when polarization is kept constant. For better understanding, the magnetic noise of spin modulated magnetometer is demonstrated and compared to SERF magnetometer. The magnetic noise measurement experiment is designed, the experimental results are consistent with the theoretical prediction. This paper validate the unique property of spin modulated magnetometer and this property will play an important role in guiding the optimization of future experiments.

DOI
10.4028/www.scientific.net/kem.787.75

Related papers

In-Situ Relaxation Rate Measurement in Magnetic Modulated Atomic Magnetometers

Kaifeng Yin, Binquan Zhou, Jixi Lu +4 more

Traditional practice of suppressing low-frequency noise in atomic magnetometers is mainly through the application of magnetic field modulation, while magnetic fields of this kind introduce extra transverse relaxation, which results in a decrease of sensitivity. In this study, a novel method of measuring relaxation rate induced by spin-destruction, wall collisions and modulation magnetic fields is proposed. The optical pumping model is studied both in optical-thin and optical-thick vapor cell through the analysis of total relaxation, thus the optical pumping rate can be separated from total relaxation by analyzing the optical depth. Furthermore, based on the analysis of optical pumping rate and relaxation rate, the polarization of the electron ensemble was evaluated. A compact magnetometer with single-beam configuration is developed for the proof of concept, and the experimental results show good agreements with theoretical calculation. Our method provides a simple and feasible approach to in-situ measurement of transverse relaxation rate and optical pumping rate with physical structure of the device untouched, which is especially advantageous for designing and optimizing compact atomic magnetometers.

IEEE Sensors Journal•Nov 30, 2021•14 citations

Effects of Stochastic Magnetic Noise on the SERF Co‐Magnetometer

Feng Li, Zhuo Wang, Wenfeng Fan +4 more

Abstract Stochastic magnetic field noise has a non‐negligible negative impact on the performance of quantum precision measurement instruments such as spin‐exchange relaxation‐free (SERF) co‐magnetometer in terms of sensitivity and stability. Conventional magnetic field error analysis and suppression methods are not applicable to stochastic magnetic field noise. In this paper, a stochastic model of the SERF co‐magnetometer is proposed to analyze the mechanism of stochastic magnetic field noise. The mean and covariance propagation model of the SERF co‐magnetometer is given based on the stochasticity model and statistical principles. The analysis of simulation experiments reveals that reducing the longitudinal electron spin polarization can somewhat reduce the standard deviation of the system output caused by stochastic magnetic field noise. And the atomic ensembles are most resistant to stochastic magnetic field noise when the electron spin polarization strongly couples with the nuclear spin polarization. Finally, the experiments verified the above conclusions. In conclusion, this paper provides theoretical and experimental support for analyzing and suppressing the effect of stochastic magnetic field noise on the SERF co‐magnetometer, which is of great significance for improving the sensitivity and stability of the measurement.

Advanced Quantum Technologies•Apr 19, 2024•6 citations

A Novel Measurement Method for Spin Polarization Three Axis Spatial Distribution in Spin-Exchange Relaxation Free Atomic Magnetometer

Xiujie Fang, Jin Chun Li, Yanning Ma +5 more

The measurement of atomic spin polarization distribution in spin-exchange relaxation free (SERF) magnetometer is an important topic for improving the sensitivity and consistency of multi-channel magnetic field measurement applications. A novel spin polarization spatial distribution measurement method is presented based on the transient response of the magnetometer after modulating the pumped light with a chopper. Polarization is obtained by a slow-down factor based on the fast spin-exchange interaction effects. Longitudinal and transverse polarization distributions are measured simultaneously without interrupting the operation of the SERF status. Under different oscillating magnetic fields, the spin polarization is measured at the cell centroid. Residual magnetic field inside the magnetometer is obtained from the linear relationship between the precession frequency and the oscillating magnetic field. The one-dimensional polarization distributions in the x, y, and z axes are measured using a digital micromirror device with a resolution of 0.25 cm. The measurement results conform to the Lambert-Bier absorption law and the Gaussian distribution law. Furthermore, 7 × 7 two-dimensional spatial distribution measurements of polarization on the xy and yz planes are performed. Nonuniformity of 1.04 in the xy plane and 1.82 in the yz plane in the built magnetometer. Compared with other measurement methods, the distribution measurement method proposed is independent of optical depth and suitable for low polarization and high polarization applications. Based on the results of the proposed measurement method of spin polarization spatial distribution, further compensation can improve the application consistency of multi-channel magnetic field measurements and improve the sensitivity of single-channel differential measurements.

Photonics•Mar 20, 2023•2 citations

Comprehensive analysis of the influence of magnetic field gradients on single-beam SERF atomic magnetometer

Jiajie Li, Ying Liu, Renjie Li +3 more

Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model,we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.

Results in Physics•Nov 30, 2023•11 citations

Measurement Sensitivity Improvement of All-Optical Atomic Spin Magnetometer by Suppressing Noises

Xiyuan Chen, Hong Zhang, Sheng Zou

Quantum manipulation technology and photoelectric detection technology have jointly facilitated the rapid development of ultra-sensitive atomic spin magnetometers. To improve the output signal and sensitivity of the spin-exchange-relaxation-free (SERF) atomic spin magnetometer, the noises influencing on the output signal and the sensitivity were analyzed, and the corresponding noise suppression methods were presented. The magnetic field noises, including the residual magnetic field noise and the light shift noise, were reduced to approximately zero by employing the magnetic field compensation method and by adjusting the frequency of the pump beam, respectively. With respect to the operation temperature, the simulation results showed that the temperature of the potassium atomic spin magnetometer realizing the spin-exchange relaxation-free regime was 180 °C. Moreover, the fluctuation noises of the frequency and the power were suppressed by using the frequency and the power stable systems. The experimental power stability results showed that the light intensity stability was enhanced 10%. Contrast experiments on the sensitivity were carried out to demonstrate the validity of the suppression methods. Finally, a sensitivity of 13 fT/Hz(1/2) was successfully achieved by suppressing noises and optimizing parameters.

Sensors•Jun 17, 2016•9 citations

Probe noise characteristics of the spin-exchange relaxation-free (SERF) magnetometer

Bozheng Xing, Chang Sun, Ziao Liu +4 more

In the spin-exchange relaxation-free (SERF) magnetometer, the probe noise is a consequential factor affecting the gradiometric measurement sensitivities. In this paper, we proposed a new characteristics model of the probe noise based on noise separation. Different from noise analysis on single noise source, we considered most of the noise sources influencing the probe system and realized noise sources level measurement experimentally. The results demonstrate that the major noise type changes with the signal frequency. Below 10 Hz, the probe noise mainly comes from the sources independent of light intensity such as the vibration, which accounts for more than 50%; while at 30 Hz, the photon shot noise and the magnetic noise are the main origins, with proportion about 43% and 32%, respectively. Moreover, the results indicate that the optimal probe light intensity with highest sensitivity appears when the response of the magnetic noise is equal to the sum of the electronic noise and half of the shot noise. The optimal intensity gets larger with higher signal frequency. The noise characteristics model could be applied in modulating or differential optical systems and helps sensitivity improvement in SERF magnetometer.

Optics Express•Jan 25, 2021•30 citations
This paper presents a spin modulated atomic magnetometer, different from other kinds of atomic magnetometers, the conversion coefficient between the polarization signal and the magnetic field to be measured is independent of the transverse relaxation time, which means that the higher sensitivity can be achieved when polarization is kept constant. For better understanding, the magnetic noise of spin modulated magnetometer is demonstrated and compared to SERF magnetometer. The magnetic noise measurement experiment is designed, the experimental results are consistent with the theoretical prediction. This paper validate the unique property of spin modulated magnetometer and this property will play an important role in guiding the optimization of future experiments.
Traditional practice of suppressing low-frequency noise in atomic magnetometers is mainly through the application of magnetic field modulation, while magnetic fields of this kind introduce extra transverse relaxation, which results in a decrease of sensitivity. In this study, a novel method of measuring relaxation rate induced by spin-destruction, wall collisions and modulation magnetic fields is proposed. The optical pumping model is studied both in optical-thin and optical-thick vapor cell through the analysis of total relaxation, thus the optical pumping rate can be separated from total relaxation by analyzing the optical depth. Furthermore, based on the analysis of optical pumping rate and relaxation rate, the polarization of the electron ensemble was evaluated. A compact magnetometer with single-beam configuration is developed for the proof of concept, and the experimental results show good agreements with theoretical calculation. Our method provides a simple and feasible approach to in-situ measurement of transverse relaxation rate and optical pumping rate with physical structure of the device untouched, which is especially advantageous for designing and optimizing compact atomic magnetometers.
Abstract Stochastic magnetic field noise has a non‐negligible negative impact on the performance of quantum precision measurement instruments such as spin‐exchange relaxation‐free (SERF) co‐magnetometer in terms of sensitivity and stability. Conventional magnetic field error analysis and suppression methods are not applicable to stochastic magnetic field noise. In this paper, a stochastic model of the SERF co‐magnetometer is proposed to analyze the mechanism of stochastic magnetic field noise. The mean and covariance propagation model of the SERF co‐magnetometer is given based on the stochasticity model and statistical principles. The analysis of simulation experiments reveals that reducing the longitudinal electron spin polarization can somewhat reduce the standard deviation of the system output caused by stochastic magnetic field noise. And the atomic ensembles are most resistant to stochastic magnetic field noise when the electron spin polarization strongly couples with the nuclear spin polarization. Finally, the experiments verified the above conclusions. In conclusion, this paper provides theoretical and experimental support for analyzing and suppressing the effect of stochastic magnetic field noise on the SERF co‐magnetometer, which is of great significance for improving the sensitivity and stability of the measurement.
The measurement of atomic spin polarization distribution in spin-exchange relaxation free (SERF) magnetometer is an important topic for improving the sensitivity and consistency of multi-channel magnetic field measurement applications. A novel spin polarization spatial distribution measurement method is presented based on the transient response of the magnetometer after modulating the pumped light with a chopper. Polarization is obtained by a slow-down factor based on the fast spin-exchange interaction effects. Longitudinal and transverse polarization distributions are measured simultaneously without interrupting the operation of the SERF status. Under different oscillating magnetic fields, the spin polarization is measured at the cell centroid. Residual magnetic field inside the magnetometer is obtained from the linear relationship between the precession frequency and the oscillating magnetic field. The one-dimensional polarization distributions in the x, y, and z axes are measured using a digital micromirror device with a resolution of 0.25 cm. The measurement results conform to the Lambert-Bier absorption law and the Gaussian distribution law. Furthermore, 7 × 7 two-dimensional spatial distribution measurements of polarization on the xy and yz planes are performed. Nonuniformity of 1.04 in the xy plane and 1.82 in the yz plane in the built magnetometer. Compared with other measurement methods, the distribution measurement method proposed is independent of optical depth and suitable for low polarization and high polarization applications. Based on the results of the proposed measurement method of spin polarization spatial distribution, further compensation can improve the application consistency of multi-channel magnetic field measurements and improve the sensitivity of single-channel differential measurements.
Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model,we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.
Quantum manipulation technology and photoelectric detection technology have jointly facilitated the rapid development of ultra-sensitive atomic spin magnetometers. To improve the output signal and sensitivity of the spin-exchange-relaxation-free (SERF) atomic spin magnetometer, the noises influencing on the output signal and the sensitivity were analyzed, and the corresponding noise suppression methods were presented. The magnetic field noises, including the residual magnetic field noise and the light shift noise, were reduced to approximately zero by employing the magnetic field compensation method and by adjusting the frequency of the pump beam, respectively. With respect to the operation temperature, the simulation results showed that the temperature of the potassium atomic spin magnetometer realizing the spin-exchange relaxation-free regime was 180 °C. Moreover, the fluctuation noises of the frequency and the power were suppressed by using the frequency and the power stable systems. The experimental power stability results showed that the light intensity stability was enhanced 10%. Contrast experiments on the sensitivity were carried out to demonstrate the validity of the suppression methods. Finally, a sensitivity of 13 fT/Hz(1/2) was successfully achieved by suppressing noises and optimizing parameters.
In the spin-exchange relaxation-free (SERF) magnetometer, the probe noise is a consequential factor affecting the gradiometric measurement sensitivities. In this paper, we proposed a new characteristics model of the probe noise based on noise separation. Different from noise analysis on single noise source, we considered most of the noise sources influencing the probe system and realized noise sources level measurement experimentally. The results demonstrate that the major noise type changes with the signal frequency. Below 10 Hz, the probe noise mainly comes from the sources independent of light intensity such as the vibration, which accounts for more than 50%; while at 30 Hz, the photon shot noise and the magnetic noise are the main origins, with proportion about 43% and 32%, respectively. Moreover, the results indicate that the optimal probe light intensity with highest sensitivity appears when the response of the magnetic noise is equal to the sum of the electronic noise and half of the shot noise. The optimal intensity gets larger with higher signal frequency. The noise characteristics model could be applied in modulating or differential optical systems and helps sensitivity improvement in SERF magnetometer.