Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Frontiers in Optics

Progress towards a three-node free-space clock network

Paritosh Manurkar, Sarah Stevenson, Isaac H. Khader, Jean-Daniel Deschênes, William C. Swann, Nathan R. Newbury, Laura C. Sinclair

Published Jan 1, 2018• 1 citation
Publisher

Abstract

We report the latest progress towards the development of a three-node free-space clock network. We will demonstrate clock comparison between two optical nodes via coherent time/frequency transfer through a third node.
DOI
10.1364/fio.2018.fth3c.4

Related papers

Synchronization of distant optical clocks across free-space optical links

Nathan R. Newbury, Laura C. Sinclair, Hugo Bergeron +6 more

The continued remarkable advances in optical clocks and oscillators has led to a parallel strong development of optical clock networks [1]. Such networks have the potential to support a wide range of applications from basic time/frequency dissemination, to clock-based geodesy, to tests of general relativity [1]. To support optical clocks/oscillators at their highest accuracy and precision, these networks must rely on optical signals between the nodes to carry the timing signals. Networks based on the reciprocal transmission across fiber optics have allowed frequency comparisons between remote clocks across Europe and Japan [2, 3]. However, there are many potential applications, both terrestrial and space-based, for which the clocks will not be connected via an optical fiber and the signals must be sent across free space optical links. To this end, we have been developing techniques for the free-space transfer of time and frequency [4-6]. Moreover, rather than pursuing only frequency comparison, we have developed an approach that allows time comparison and even real-time synchronization between nodes. Such a capability can support the wide variety of proposed applications of mobile optical clock networks.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations

Free-Space Optical Time Transfer between an Atomic Frequency Standard and a Simple Optical Clock

Matthew S. Bigelow, Rafe Guidice, Kyle W. Martin +2 more

Conference on Lasers and Electro-Optics•Jan 1, 2019•3 citations

Viewpoint: Next Generation Clock Networks

Peter Wolf

Free-space laser links have been used to synchronize optical clocks with an unprecedented uncertainty of femtoseconds.

•May 11, 2016•1 citation

Optical time-frequency transfer across a free-space, three-node network

Martha I. Bodine, Jennifer L. Ellis, William C. Swann +6 more

We demonstrate frequency-comb-based optical two-way time-frequency transfer across a three-node clock network. A fielded, bidirectional relay node connects laboratory-based master and end nodes, allowing the network to span 28 km of turbulent outdoor air while keeping optical transmit powers below 5 mW. Despite the comparatively high instability of the free-running local oscillator at the relay node, the network transfers frequency with fractional precision below 10−18 at averaging times above 200 s and transfers time with a time deviation below 1 fs at averaging times between 1 s and 1 h. The successful operation of this network represents a promising step toward the operation of future free-space networks of optical atomic clocks.

APL Photonics•Jul 1, 2020•50 citations

Optical Two-Way Time-Frequency Transfer across a Three-Node Free-Space Network

Martha I. Bodine, Jennifer L. Ellis, William C. Swann +6 more

We demonstrate optical two-way time-frequency transfer (O-TWTFT) across a three-node free-space network. The network spans 28 km of outdoor air and relays time and frequency from a master node, through an intermediate fielded node, to an end node. Despite strong atmospheric turbulence along the close-to-ground free-space links and large ambient temperature swings at the fielded node, the network transfers time with relative timing offsets below 5 fs. Additionally, the network transfers frequency with instability below 10-18at averaging times greater than 200 s-i.e. below the level needed to compare state-of-the-art optical atomic clocks.

IEEE Photonics Conference•Sep 1, 2020•0 citations

Application of quantum-limited optical time transfer to space-based optical clock comparisons and coherent networks

Emily D. Caldwell, Laura C. Sinclair, Jean-Daniel Deschênes +2 more

With the demonstration of quantum-limited optical time transfer capable of tolerating the losses associated with long ground-to-space links, two future applications of free-space time transfer have emerged: intercontinental clock comparisons for time dissemination and coherence transfer for future distributed sensing in the mm-wave region. In this paper, we estimated the projected performance of these two applications using quantum-limited optical time transfer and assuming existing low-size, low-weight, and low-power hardware. In both cases, we limit the discussion to the simplest case of a single geosynchronous satellite linked to either one or two ground stations. One important consideration for such future space-based operations is the choice of reference oscillator onboard the satellite. We find that with a modestly performing optical reference oscillator and low-power fiber-based frequency combs, quantum-limited time transfer could support intercontinental clock comparisons through a common-view node in geostationary orbit with a modified Allan deviation at the 10−16 level at 10-s averaging time, limited primarily by residual turbulence piston noise. In the second application of coherence transfer from ground-to-geosynchronous orbit, we find the system should support high short-term coherence with ∼10 millirad phase noise on a 300 GHz carrier at essentially unlimited integration times.

APL Photonics•Jan 1, 2024•14 citations
The continued remarkable advances in optical clocks and oscillators has led to a parallel strong development of optical clock networks [1]. Such networks have the potential to support a wide range of applications from basic time/frequency dissemination, to clock-based geodesy, to tests of general relativity [1]. To support optical clocks/oscillators at their highest accuracy and precision, these networks must rely on optical signals between the nodes to carry the timing signals. Networks based on the reciprocal transmission across fiber optics have allowed frequency comparisons between remote clocks across Europe and Japan [2, 3]. However, there are many potential applications, both terrestrial and space-based, for which the clocks will not be connected via an optical fiber and the signals must be sent across free space optical links. To this end, we have been developing techniques for the free-space transfer of time and frequency [4-6]. Moreover, rather than pursuing only frequency comparison, we have developed an approach that allows time comparison and even real-time synchronization between nodes. Such a capability can support the wide variety of proposed applications of mobile optical clock networks.
We demonstrate frequency-comb-based optical two-way time-frequency transfer across a three-node clock network. A fielded, bidirectional relay node connects laboratory-based master and end nodes, allowing the network to span 28 km of turbulent outdoor air while keeping optical transmit powers below 5 mW. Despite the comparatively high instability of the free-running local oscillator at the relay node, the network transfers frequency with fractional precision below 10−18 at averaging times above 200 s and transfers time with a time deviation below 1 fs at averaging times between 1 s and 1 h. The successful operation of this network represents a promising step toward the operation of future free-space networks of optical atomic clocks.
We demonstrate optical two-way time-frequency transfer (O-TWTFT) across a three-node free-space network. The network spans 28 km of outdoor air and relays time and frequency from a master node, through an intermediate fielded node, to an end node. Despite strong atmospheric turbulence along the close-to-ground free-space links and large ambient temperature swings at the fielded node, the network transfers time with relative timing offsets below 5 fs. Additionally, the network transfers frequency with instability below 10-18at averaging times greater than 200 s-i.e. below the level needed to compare state-of-the-art optical atomic clocks.
With the demonstration of quantum-limited optical time transfer capable of tolerating the losses associated with long ground-to-space links, two future applications of free-space time transfer have emerged: intercontinental clock comparisons for time dissemination and coherence transfer for future distributed sensing in the mm-wave region. In this paper, we estimated the projected performance of these two applications using quantum-limited optical time transfer and assuming existing low-size, low-weight, and low-power hardware. In both cases, we limit the discussion to the simplest case of a single geosynchronous satellite linked to either one or two ground stations. One important consideration for such future space-based operations is the choice of reference oscillator onboard the satellite. We find that with a modestly performing optical reference oscillator and low-power fiber-based frequency combs, quantum-limited time transfer could support intercontinental clock comparisons through a common-view node in geostationary orbit with a modified Allan deviation at the 10−16 level at 10-s averaging time, limited primarily by residual turbulence piston noise. In the second application of coherence transfer from ground-to-geosynchronous orbit, we find the system should support high short-term coherence with ∼10 millirad phase noise on a 300 GHz carrier at essentially unlimited integration times.