European Frequency and Time Forum

Ramsey-mode Rb cell clock demonstration with a 3D-printed microwave cavity

William Moreno, C. Affolderbach, Matthieu Pellaton, G. Mileti, A. E. Ivanov, Anja K. Skrivervik, Tomislav Debogović, S. Capdevila, D. Hoerni, E. deRijk

Published Apr 1, 2018• 5 citations
Publisher

Abstract

We demonstrate operation of a Ramey-mode Rb vapor-cell atomic clock based on a microwave cavity realized by additive manufacturing (3D-printing). The cavity design is based on a loop-gap approach and its critical electrode structure is realized in one monolithic piece by stereolithography of a polymer which simplifies the assembly of the cavity. The microwave magnetic field in the cavity shows excellent uniformity and high homogeneity across the Rb cell, which results in high-contrast Ramsey fringes observed on the clock transition. A measured clock stability of 2.2×10-13τ-1/2demonstrates the feasibility of the approach. We discuss aging studies performed on 3D-printed test samples that are of relevance for long-term operation of the clock.

DOI
10.1109/eftf.2018.8409001

Related papers

Study of additive manufactured microwave cavities for pulsed optically pumped atomic clock applications

C. Affolderbach, William Moreno, A. E. Ivanov +5 more

Additive manufacturing (AM) of passive microwave components is of high interest for the cost-effective and rapid prototyping or manufacture of devices with complex geometries. Here, we present an experimental study on the properties of recently demonstrated microwave resonator cavities manufactured by AM, in view of their applications to high-performance compact atomic clocks. The microwave cavities employ a loop-gap geometry using six electrodes. The critical electrode structures were manufactured monolithically using two different approaches: Stereolithography (SLA) of a polymer followed by metal coating and Selective Laser Melting (SLM) of aluminum. The tested microwave cavities show the desired TE011-like resonant mode at the Rb clock frequency of ≈6.835 GHz, with a microwave magnetic field highly parallel to the quantization axis across the vapor cell. When operated in an atomic clock setup, the measured atomic Rabi oscillations are comparable to those observed for conventionally manufactured cavities and indicate a good uniformity of the field amplitude across the vapor cell. Employing a time-domain Ramsey scheme on one of the SLA cavities, high-contrast (34%) Ramsey fringes are observed for the Rb clock transition, along with a narrow (166 Hz linewidth) central fringe. The measured clock stability of 2.2 × 10−13 τ−1/2 up to the integration time of 30 s is comparable to the current state-of-the-art stabilities of compact vapor-cell clocks based on conventional microwave cavities and thus demonstrates the feasibility of the approach.

Applied Physics Letters•Mar 12, 2018•22 citations

A compact cold-atom double-resonance clock

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•0 citations

μ POP Clock: A Microcell Atomic Clock Based on a Double-Resonance Ramsey Scheme

Etienne Batori, C. Affolderbach, Matthieu Pellaton +5 more

We demonstrate and study a microcell microwave atomic clock based on optical-microwave double resonance (DR) interrogation operated in a pulsed Ramsey scheme, called the \ensuremath{\mu}POP clock, based on a microfabricated Rb vapor cell and a micro-loop-gap microwave resonator. For the mm-scale dimensions of this cell, the population and coherence relaxation rates of the Rb clock transition are on the order of 4--5 kHz, which puts constraints on the useful Ramsey times and overall pulse sequence in view of optimized clock performance. Our proof-of-principle demonstration of the \ensuremath{\mu}POP clock shows that the pulsed DR approach is nevertheless feasible and results in a short-term clock stability of 1 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}11}$ \ensuremath{\tau}${}^{\ensuremath{-}1/2}$ and reaching the \ensuremath{\le}2 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}12}$ level at timescales of 1000 s to one day. The short-term instability budget established for the \ensuremath{\mu}POP clock shows that the main limitation to the short-term stability arises from the detection noise. Thanks to the pulsed Ramsey scheme, light-shift effects are strongly reduced in the \ensuremath{\mu}POP clock, which opens perspectives for further improvements of long-term clock stability, in view of future generations of miniature vapor-cell clocks with enhanced performances based on the DR scheme.

Physical Review Applied•Nov 14, 2022•30 citations

Demonstration of a high-performance pulsed optically pumped Rb clock based on a compact magnetron-type microwave cavity

Seung Won Kang, Mohammadreza Gharavipour, C. Affolderbach +2 more

We demonstrate a high-performance pulsed optically pumped (POP) Rb vapor-cell clock based on a magnetron-type microwave cavity of only 44 cm3 external volume. Using optical detection, an unprecedented 35% contrast of the Ramsey signal has been obtained. Both the signal-to-noise ratio (of 30 000) and the estimated shot-noise limit of 1.7 × 10−14 τ−1/2 are at the same level as those found with a bigger cylindrical TE011 cavity (100 cm3 inner volume) and are sufficient for achieving excellent clock stability. Rabi oscillations are measured and indicate a sufficiently uniform microwave magnetic field distribution inside the cavity. The instability sources for the POP clock's performance are analyzed. A short-term stability of 2.1 × 10−13 τ−1/2 is demonstrated which is consistent with the noise budget.

Journal of Applied Physics•Mar 12, 2015•63 citations

An additive-manufactured microwave cavity for a compact cold-atom clock

Etienne Batori, Alan Bregazzi, Ben Lewis +4 more

We present an additive-manufactured microwave cavity for a Ramsey-type, double resonance, compact cold-atom clock. Atoms can be laser cooled inside the cavity using a grating magneto-optic trap with the cavity providing an excellent TE011-like mode while maintaining sufficient optical access for atomic detection. The cavity features a low Q-factor of 360 which conveniently reduces the cavity pulling of the future clock. Despite the potential porosity of the additive-manufacturing process, we demonstrate that the cavity is well-suited for vacuum. A preliminary clock setup using cold atoms allows for measuring the Zeeman spectrum and Rabi oscillations in the cavity which enables us to infer excellent field uniformity and homogeneity, respectively, across the volume accessed by the cold atoms. Ramsey spectroscopy is demonstrated, indicating that the cavity is suitable for clock applications. Finally, we discuss the limitations of the future clock.

arXiv:2305.02898•Journal of Applied Physics•Jun 8, 2023•4 citations

Pulsed optical pumping in a Rb vapor cell using a compact magnetron-type microwave cavity

Songbai Kang, C. Affolderbach, Florian Gruet +3 more

A compact magnetron-type microwave cavity has previously been developed for a high performance Rb atomic clock based on conventional continuous-wave double-resonance (DR) interrogation. This magnetron-type cavity shows a homogenous microwave field distribution while having a cavity volume of only 35 cm3. So it is interesting for realizing a high performance Rb cell clock based on pulsed optical pumping (POP) technique with a reduced physics package size. In this proceeding we report on the evaluation of pulsed optical pumping with our magnetron-type cavity. Using the pulsed technique and optical detection, high-contrast Ramsey fringes were observed. The central fringe of the Ramsey signal has a linewidth of 160 Hz and contrast of 35%. Under these conditions, the shot-noise limit is estimated at a level around 2×10-14τ-1/2which shows the great potential of a POP clock based on the compact magnetron-type cavity. The Rabi oscillation result also indicates an acceptable uniform field distribution inside the cavity for a high-performance POP clock. Some optimizations of pumping and detection power for improving the contrast are also presented.

European Frequency and Time Forum•Jun 1, 2014•6 citations
We demonstrate operation of a Ramey-mode Rb vapor-cell atomic clock based on a microwave cavity realized by additive manufacturing (3D-printing). The cavity design is based on a loop-gap approach and its critical electrode structure is realized in one monolithic piece by stereolithography of a polymer which simplifies the assembly of the cavity. The microwave magnetic field in the cavity shows excellent uniformity and high homogeneity across the Rb cell, which results in high-contrast Ramsey fringes observed on the clock transition. A measured clock stability of 2.2×10-13τ-1/2demonstrates the feasibility of the approach. We discuss aging studies performed on 3D-printed test samples that are of relevance for long-term operation of the clock.
Additive manufacturing (AM) of passive microwave components is of high interest for the cost-effective and rapid prototyping or manufacture of devices with complex geometries. Here, we present an experimental study on the properties of recently demonstrated microwave resonator cavities manufactured by AM, in view of their applications to high-performance compact atomic clocks. The microwave cavities employ a loop-gap geometry using six electrodes. The critical electrode structures were manufactured monolithically using two different approaches: Stereolithography (SLA) of a polymer followed by metal coating and Selective Laser Melting (SLM) of aluminum. The tested microwave cavities show the desired TE011-like resonant mode at the Rb clock frequency of ≈6.835 GHz, with a microwave magnetic field highly parallel to the quantization axis across the vapor cell. When operated in an atomic clock setup, the measured atomic Rabi oscillations are comparable to those observed for conventionally manufactured cavities and indicate a good uniformity of the field amplitude across the vapor cell. Employing a time-domain Ramsey scheme on one of the SLA cavities, high-contrast (34%) Ramsey fringes are observed for the Rb clock transition, along with a narrow (166 Hz linewidth) central fringe. The measured clock stability of 2.2 × 10−13 τ−1/2 up to the integration time of 30 s is comparable to the current state-of-the-art stabilities of compact vapor-cell clocks based on conventional microwave cavities and thus demonstrates the feasibility of the approach.
We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.
We demonstrate and study a microcell microwave atomic clock based on optical-microwave double resonance (DR) interrogation operated in a pulsed Ramsey scheme, called the \ensuremath{\mu}POP clock, based on a microfabricated Rb vapor cell and a micro-loop-gap microwave resonator. For the mm-scale dimensions of this cell, the population and coherence relaxation rates of the Rb clock transition are on the order of 4--5 kHz, which puts constraints on the useful Ramsey times and overall pulse sequence in view of optimized clock performance. Our proof-of-principle demonstration of the \ensuremath{\mu}POP clock shows that the pulsed DR approach is nevertheless feasible and results in a short-term clock stability of 1 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}11}$ \ensuremath{\tau}${}^{\ensuremath{-}1/2}$ and reaching the \ensuremath{\le}2 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}12}$ level at timescales of 1000 s to one day. The short-term instability budget established for the \ensuremath{\mu}POP clock shows that the main limitation to the short-term stability arises from the detection noise. Thanks to the pulsed Ramsey scheme, light-shift effects are strongly reduced in the \ensuremath{\mu}POP clock, which opens perspectives for further improvements of long-term clock stability, in view of future generations of miniature vapor-cell clocks with enhanced performances based on the DR scheme.
We demonstrate a high-performance pulsed optically pumped (POP) Rb vapor-cell clock based on a magnetron-type microwave cavity of only 44 cm3 external volume. Using optical detection, an unprecedented 35% contrast of the Ramsey signal has been obtained. Both the signal-to-noise ratio (of 30 000) and the estimated shot-noise limit of 1.7 × 10−14 τ−1/2 are at the same level as those found with a bigger cylindrical TE011 cavity (100 cm3 inner volume) and are sufficient for achieving excellent clock stability. Rabi oscillations are measured and indicate a sufficiently uniform microwave magnetic field distribution inside the cavity. The instability sources for the POP clock's performance are analyzed. A short-term stability of 2.1 × 10−13 τ−1/2 is demonstrated which is consistent with the noise budget.
We present an additive-manufactured microwave cavity for a Ramsey-type, double resonance, compact cold-atom clock. Atoms can be laser cooled inside the cavity using a grating magneto-optic trap with the cavity providing an excellent TE011-like mode while maintaining sufficient optical access for atomic detection. The cavity features a low Q-factor of 360 which conveniently reduces the cavity pulling of the future clock. Despite the potential porosity of the additive-manufacturing process, we demonstrate that the cavity is well-suited for vacuum. A preliminary clock setup using cold atoms allows for measuring the Zeeman spectrum and Rabi oscillations in the cavity which enables us to infer excellent field uniformity and homogeneity, respectively, across the volume accessed by the cold atoms. Ramsey spectroscopy is demonstrated, indicating that the cavity is suitable for clock applications. Finally, we discuss the limitations of the future clock.
A compact magnetron-type microwave cavity has previously been developed for a high performance Rb atomic clock based on conventional continuous-wave double-resonance (DR) interrogation. This magnetron-type cavity shows a homogenous microwave field distribution while having a cavity volume of only 35 cm3. So it is interesting for realizing a high performance Rb cell clock based on pulsed optical pumping (POP) technique with a reduced physics package size. In this proceeding we report on the evaluation of pulsed optical pumping with our magnetron-type cavity. Using the pulsed technique and optical detection, high-contrast Ramsey fringes were observed. The central fringe of the Ramsey signal has a linewidth of 160 Hz and contrast of 35%. Under these conditions, the shot-noise limit is estimated at a level around 2×10-14τ-1/2which shows the great potential of a POP clock based on the compact magnetron-type cavity. The Rabi oscillation result also indicates an acceptable uniform field distribution inside the cavity for a high-performance POP clock. Some optimizations of pumping and detection power for improving the contrast are also presented.