Review of Scientific Instruments

Note: Pulsed optically pumped atomic clock based on a paraffin-coated cell

Haixiao Lin, Jianliao Deng, Jinda Lin, Song Zhang, Yao Hu, Yuzhu Wang

Published Jun 1, 2018• 4 citations
Publisher

Abstract

We report on the implementation of a pulsed optically pumped atomic clock based on a paraffin-coated cell. The relaxation times are measured, with the longitudinal relaxation time, T1 = 9.7 ± 0.4 ms, and the transversal relaxation time, T2 = 0.40 ± 0.03 ms. We demonstrated that the measured frequency stability of the clock is 3.9 × 10−13 τ−1/2 (1 s ≤ τ ≤ 100 s) and reaches a value of 3.1 × 10−14 for τ = 1000 s, where τ is the averaging time. This is an unprecedented result for a paraffin-coated vapor cell clock, and it makes significant contributions toward improving the performance of the wall-coated vapor cell atomic clock.

DOI
10.1063/1.5030956

Related papers

Laser-pumped paraffin-coated cell rubidium frequency standard

Thejesh Bandi, C. Affolderbach, G. Mileti

We have realized and studied a rubidium atomic frequency standard based on a paraffin-coated cell, exhibiting a short-term frequency stability <3 × 10−12 τ−1/2 between τ = 1 and 100 s. Characterization of the wall-coating is performed by measuring the T1 and T2 relaxation times. Perturbations of the medium- to long-term clock stability, due to variations in the laser-intensity, laser frequency, the microwave power shift, and the shifts due to temperature variations are measured and analyzed. A method for reducing the intensity light-shift by detuning the laser frequency and the resulting improvement in clock stability is demonstrated. This work is of relevance for further improvements on Rb cell standards using anti-relaxation wall-coating technology.

Journal of Applied Physics•Jun 15, 2012•37 citations

Pulsed optically pumped rubidium clock with high frequency-stability performance

Salvatore Micalizio, A. Godone, Claudio Eligio Calosso +3 more

In this paper, we present the performance of a vapor-cell rubidium frequency standard working in the pulsed regime, in which the clock signal is represented by a Ramsey pattern observed on an optically detected laser absorption signal. The main experimental results agree with previously reported theoretical predictions. In particular, we measured a relative frequency stability of σy(τ) - 1.6 × 10(-13)τ-1/2 for integration times, τ, up to 200 s, which represents a record in short-term stability for a vapor-cell clock. We also discuss the most important physical phenomena that contribute to this result.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2012•30 citations

Study of coherent population trapping occurring in 87Rb atoms contained in wall-coated cells

Evelina Breschi, G. Mileti

We report on the continuous CPT-interrogation of87Rb atoms contained in a paraffin wall-coated cell. Based on the signal-to-noise measurements we predict a short-term stability better than 10-12tau-1/2. This result confirms the interest on wall-coated cells for applications in high performance and compact vapor cell atomic clocks. We also report on our results on the influence of the cell temperature in the clock signal which has not be studied in this specific case as far as we know.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•1 citation

Improving short and long term stability of pulsed optically pumped vapor cell frequency standards

Salvatore Micalizio, A. Godone, Filippo Levi +1 more

In this paper we discuss how to improve both short and medium-long term frequency stability of a vapor cell frequency standard working in pulsed regime. We propose in particular a multi-step pumping technique that is able to put almost all the atoms in one of the two clock levels, increasing in this way the signal-to-noise ratio with respect to the usual optical pumping made with a single laser pulse. Moreover, we discuss the phenomena affecting the medium-long term frequency stability and how it is possible to control them, making the overall clock stability compatible with sigmay(tau) =3x10-13tau-frac12for integration times up to tau = 105s.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•0 citations

Improvement of short-term stability of pulsed optically pumped rubidium atomic clock

I. H. Choi, S. B. Lee, Taeg Yong Kwon +1 more

We present a87Rb vapor-cell atomic clock using pulsed optical pumping with an optical detection technique. The pulsed optical pumping technique can eliminate the light shifts and increase the stability of vapor-cell atomic clock. For simplicity, direct laser absorption signal is used for the detection of a clock transition. A frequency stability of about 2×10-11at 1s has been measured and short term stability is improved by reducing the pulse sequence time with a real time control system.

•Jun 1, 2010•1 citation

Pulsed optically pumped Rb clock: A high stability vapor cell frequency standard

Filippo Levi, Claudio Eligio Calosso, A. Godone +1 more

In this paper we report the results we obtained with a prototype of pulsed optically pumped (POP) Rb clock. In terms of frequency stability, an Allan deviation σy(τ)=1.7 ×10-13τ-1/2has been measured, where τ is the integration time. In addition, the long term frequency drift results below 10-14/day. In the paper we also describe a technique to stabilize the amplitude of the microwave signal using the atoms themselves as discriminator. Moreover, an anomalously large temperature sensitivity of the clock frequency and a technique to keep it under control are also reported. Finally, we describe some non linear effects that modify the shape of the clock signal represented by the Ramsey central fringe.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•1 citation
We report on the implementation of a pulsed optically pumped atomic clock based on a paraffin-coated cell. The relaxation times are measured, with the longitudinal relaxation time, T1 = 9.7 ± 0.4 ms, and the transversal relaxation time, T2 = 0.40 ± 0.03 ms. We demonstrated that the measured frequency stability of the clock is 3.9 × 10−13 τ−1/2 (1 s ≤ τ ≤ 100 s) and reaches a value of 3.1 × 10−14 for τ = 1000 s, where τ is the averaging time. This is an unprecedented result for a paraffin-coated vapor cell clock, and it makes significant contributions toward improving the performance of the wall-coated vapor cell atomic clock.
We have realized and studied a rubidium atomic frequency standard based on a paraffin-coated cell, exhibiting a short-term frequency stability <3 × 10−12 τ−1/2 between τ = 1 and 100 s. Characterization of the wall-coating is performed by measuring the T1 and T2 relaxation times. Perturbations of the medium- to long-term clock stability, due to variations in the laser-intensity, laser frequency, the microwave power shift, and the shifts due to temperature variations are measured and analyzed. A method for reducing the intensity light-shift by detuning the laser frequency and the resulting improvement in clock stability is demonstrated. This work is of relevance for further improvements on Rb cell standards using anti-relaxation wall-coating technology.
In this paper, we present the performance of a vapor-cell rubidium frequency standard working in the pulsed regime, in which the clock signal is represented by a Ramsey pattern observed on an optically detected laser absorption signal. The main experimental results agree with previously reported theoretical predictions. In particular, we measured a relative frequency stability of σy(τ) - 1.6 × 10(-13)τ-1/2 for integration times, τ, up to 200 s, which represents a record in short-term stability for a vapor-cell clock. We also discuss the most important physical phenomena that contribute to this result.
In this paper we discuss how to improve both short and medium-long term frequency stability of a vapor cell frequency standard working in pulsed regime. We propose in particular a multi-step pumping technique that is able to put almost all the atoms in one of the two clock levels, increasing in this way the signal-to-noise ratio with respect to the usual optical pumping made with a single laser pulse. Moreover, we discuss the phenomena affecting the medium-long term frequency stability and how it is possible to control them, making the overall clock stability compatible with sigmay(tau) =3x10-13tau-frac12for integration times up to tau = 105s.
In this paper we report the results we obtained with a prototype of pulsed optically pumped (POP) Rb clock. In terms of frequency stability, an Allan deviation σy(τ)=1.7 ×10-13τ-1/2has been measured, where τ is the integration time. In addition, the long term frequency drift results below 10-14/day. In the paper we also describe a technique to stabilize the amplitude of the microwave signal using the atoms themselves as discriminator. Moreover, an anomalously large temperature sensitivity of the clock frequency and a technique to keep it under control are also reported. Finally, we describe some non linear effects that modify the shape of the clock signal represented by the Ramsey central fringe.