Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Improving the Collection Efficiency of Bulk Diamond NV Center Fluorescence with Solid Immersion Lenses

T.O. Brundage, Sorawis Sangtawesin, J. R. Petta

Published Mar 20, 2013• 0 citations
OpenAlex

Related papers

Collection Efficiency Improvement of NV center by Selective Growth of Diamond

Satoko Furuyama

The Japan Society of Applied Physics•Feb 6, 2015•0 citations

Nanostructured Diamond for Enhanced Collection Efficiency from NV Centers

Brendan Shields, Nathalie P. de Leon, Alexander S. Zibrov +2 more

Bulletin of the American Physical Society•Jun 6, 2013•0 citations

Strongly enhanced photon collection from diamond defect centers under microfabricated integrated solid immersion lenses

John Patrick Hadden, J. P. Harrison, A. C. Stanley‐Clarke +5 more

The efficiency of photon collection from optically active defect centers in bulk diamond is greatly reduced by refraction at the diamond-air interface. We report on the fabrication and measurement of a geometrical solution to the problem; integrated solid immersion lenses (SILs) etched directly into the surface of diamond. An increase of a factor of 10 was observed in the saturated count-rate from a single negatively charged nitrogen-vacancy (NV−) within a 5 μm diameter SIL compared with NV−’s under a planar surface in the same crystal. Such a system is potentially scalable and easily adaptable to other defect centers in bulk diamond.

arXiv:1006.2093•Applied Physics Letters•Dec 13, 2010•292 citations

Towards quantum computing using nitrogen vacancy centers: optimising photon collection

Mai, ZF

Nitrogen vacancy centres in diamond have shown strong potential for use as qubits in quantum computing. However, nitrogen vacancy centres have a low percentage of overall emission emitted through the Zero Phonon Line (ZPL). In addition, the fabrication of NV centres with controlled positioning is limited. This thesis presents the ZPL linewidth characterisation of NV centres fabricated using laser writing and laser diffusion. Only one out of the six NV centres characterised showed a <100 MHz average single scan linewidth, which suggests that the laser diffusion process needs to improved. The low ZPL emission can be enhanced by cavity coupling to Fabry-Pérot microcavities. Fabry-Pérot microcavities are susceptible to vibrations, which will decouple the cavity from the NV centre and reduce the photon enhancement. A cavity stabilisation system based on cavity fringe stabilisation is implemented, and the results of the stability are presented. The Fabry-Pérot microcavity can be stabilised with 0.13 nm using fringe stabilisation. High collection efficiency of the emission is also desired for maximising the entanglement rate and is reduced by optical aberrations. For NV centres in bulk diamond, using Solid Immersion Lenses (SILs) removes the spherical aberration that is introduced when collecting NV emission through a planar interface. This thesis presents the results of modelling the aberrations for NV centres cavity coupled to a Fabry-Pérot microcavity and for hemispherical SILs on diamond. The wavefronts of the aberrations introduced by the planar mirror of the microcavity and the aberrations introduced by the positioning error of the SIL are modelled numerically. A deformable mirror is implemented into a confocal microscope to monitor the aberrations of the photonic devices and the results are compared with the numerical model. For Fabry-Pérot microcavities, the intensity loss caused by the aberrations introduced by the planar mirror was predicted to be less than 10 \% due to the thin mirror substrate and low numerical aperture of the cavity mode. This prediction was consistent with the experimental results where an effective 3 \% increase in light collection was observed with aberration correction. For the SILs, the model predicts that the collection efficiency is more sensitive to the lateral positioning of the SIL relative to the NV centre than the axial positioning error.

•Jan 1, 2024•0 citations

Study on fluorescence collection enhancement of NV color centers in diamond by anti-reflection gradient refractive index diamond-like coatings

Zhiyu He, Yang Du, Xin Tan +4 more

Photonics and Nanostructures - Fundamentals and Applications•Aug 8, 2025•1 citation

Laser written nitrogen vacancy centers in diamond integrated with transfer print GaN solid immersion lenses

Xingrui Cheng, Nils Kolja Wessling, Saptarsi Ghosh +9 more

Laser-written Nitrogen Vacancy (NV−) centers are combined with transfer-printed GaN micro-lenses to increase fluorescent light collection by reducing total internal reflection at the planar diamond interface. We find a 2x improvement of fluorescent light collection using a 0.95 NA air objective at room temperature, in agreement with FDTD simulations. The nature of the transfer print micro-lenses leads to better performance with lower Numerical Aperture (NA) collection, as confirmed by results with a 0.5NA air objective which show improvement greater than 5x. The approach is attractive for scalable integrated quantum technologies.

Nanoscale and Quantum Materials: From Synthesis and Laser Processing to Applications•Mar 12, 2024•0 citations
The efficiency of photon collection from optically active defect centers in bulk diamond is greatly reduced by refraction at the diamond-air interface. We report on the fabrication and measurement of a geometrical solution to the problem; integrated solid immersion lenses (SILs) etched directly into the surface of diamond. An increase of a factor of 10 was observed in the saturated count-rate from a single negatively charged nitrogen-vacancy (NV−) within a 5 μm diameter SIL compared with NV−’s under a planar surface in the same crystal. Such a system is potentially scalable and easily adaptable to other defect centers in bulk diamond.
Nitrogen vacancy centres in diamond have shown strong potential for use as qubits in quantum computing. However, nitrogen vacancy centres have a low percentage of overall emission emitted through the Zero Phonon Line (ZPL). In addition, the fabrication of NV centres with controlled positioning is limited. This thesis presents the ZPL linewidth characterisation of NV centres fabricated using laser writing and laser diffusion. Only one out of the six NV centres characterised showed a <100 MHz average single scan linewidth, which suggests that the laser diffusion process needs to improved. The low ZPL emission can be enhanced by cavity coupling to Fabry-Pérot microcavities. Fabry-Pérot microcavities are susceptible to vibrations, which will decouple the cavity from the NV centre and reduce the photon enhancement. A cavity stabilisation system based on cavity fringe stabilisation is implemented, and the results of the stability are presented. The Fabry-Pérot microcavity can be stabilised with 0.13 nm using fringe stabilisation. High collection efficiency of the emission is also desired for maximising the entanglement rate and is reduced by optical aberrations. For NV centres in bulk diamond, using Solid Immersion Lenses (SILs) removes the spherical aberration that is introduced when collecting NV emission through a planar interface. This thesis presents the results of modelling the aberrations for NV centres cavity coupled to a Fabry-Pérot microcavity and for hemispherical SILs on diamond. The wavefronts of the aberrations introduced by the planar mirror of the microcavity and the aberrations introduced by the positioning error of the SIL are modelled numerically. A deformable mirror is implemented into a confocal microscope to monitor the aberrations of the photonic devices and the results are compared with the numerical model. For Fabry-Pérot microcavities, the intensity loss caused by the aberrations introduced by the planar mirror was predicted to be less than 10 \% due to the thin mirror substrate and low numerical aperture of the cavity mode. This prediction was consistent with the experimental results where an effective 3 \% increase in light collection was observed with aberration correction. For the SILs, the model predicts that the collection efficiency is more sensitive to the lateral positioning of the SIL relative to the NV centre than the axial positioning error.
Laser-written Nitrogen Vacancy (NV−) centers are combined with transfer-printed GaN micro-lenses to increase fluorescent light collection by reducing total internal reflection at the planar diamond interface. We find a 2x improvement of fluorescent light collection using a 0.95 NA air objective at room temperature, in agreement with FDTD simulations. The nature of the transfer print micro-lenses leads to better performance with lower Numerical Aperture (NA) collection, as confirmed by results with a 0.5NA air objective which show improvement greater than 5x. The approach is attractive for scalable integrated quantum technologies.