Conference on Lasers and Electro-Optics

Sub-mHz Spectral Purity Transfer for Next Generation Strontium Optical Atomic Clocks

Michele Giunta, W. Hänsel, M. Lezius, Marc Fischer, Ronald Holzwarth

Published Jan 1, 2018• 1 citation
Publisher

Abstract

We report on a Er:fiber-based optical frequency comb transferring the stability of ultra-stable lasers from 194THz to 429THz. Sub-mHz level transfer to a fiber-delivered 698.44nm output port for future Strontium QPN-limited lattice clocks is demonstrated.
DOI
10.1364/cleo_si.2018.sm1l.5

Related papers

Sub-Hz Spectral Purity Transfer at the 10–18 level based on optical frequency comb

P. Zou, Michele Giunta, W. Hänsel +3 more

We report on a Er:fiber-based optical frequency comb transferring the stability of ultra-stable lasers from 194THz to 429THz. Sub-Hz level transfer to a fiber-delivered 698.44nm output port for future Strontium QPN-limited lattice clocks is demonstrated.

•Jan 1, 2018•0 citations

Simultaneous spectral purity transfer at three optical clock transitions using an ultra-low noise Er:Fiber frequency comb

Michele Giunta, W. Hänsel, Marc Fischer +2 more

We have performed a multi-branch Er:fiber-based frequency comb comparison for simultaneously address the stability at different spectral regions. The optical beats are synchronously realized for three relevant wavelengths, corresponding to half the Sr, Yb and Hg lattice clock transition frequencies, showing an integrated phase noise below 55 mrad (1 Hz-1 MHz) and modified ADEV of ~6×10-18at 1 s, averaging below 1×10-18in <;20 s (Lambda-mode, 1 s gate time).

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•4 citations

All-polarization-maintaining, single-port Er:fiber comb for high-stability comparison of optical lattice clocks

Noriaki Ohmae, Naoya Kuse, Martin E. Fermann +1 more

All-polarization-maintaining, single-port Er:fiber combs offer long-term robust operation as well as high stability. We have built two such combs and evaluated the transfer noise for linking optical clocks. A uniformly broadened spectrum over 135–285 THz with a high signal-to-noise ratio enables the optical frequency measurement of the subharmonics of strontium, ytterbium, and mercury optical lattice clocks with the fractional frequency-noise power spectral density of (1–2) × 10 −17 Hz −1/2 at 1 Hz. By applying a synchronous clock comparison, the comb enables clock ratio measurements with 10 −17 instability at 1 s, which is one order of magnitude smaller than the best instability of the frequency ratio of optical lattice clocks.

arXiv:1706.00174•Applied Physics Express•May 26, 2017•39 citations

Spectral purity transfer between optical wavelengths at the 10−18 level

Daniele Nicolodi, Bérengère Argence, Wei Zhang +3 more

We present an optical frequency comb-based scheme that transfers 4.5 × 10−16fractional frequency stability from a 1062 nm wavelength laser to a 1542 nm laser. We demonstrate that this scheme does not hinder the transfer down to 3 × 10−18at 1 s, one order of magnitude better than previous reported result. This exceeds, by more than one order of magnitude, the stability of any optical oscillator demonstrated to date, and satisfies the stability requirement for quantum projection noise-limited optical lattice clocks. We will finally describe our latest efforts to apply this technique for improving the performance the LNE-SYRTE Sr-based optical lattice clocks.

Conference on Precision Electromagnetic Measurements•Aug 1, 2014•0 citations

Strontium Optical Lattice Clock at JILA

Michael E. Boyd, Andrew D. Ludlow, Seth M. Foreman +7 more

Results from the JILA optical lattice clock are presented. We report on our development of precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 times 1014) of lattice confined strontium atoms is used for both a high-performance optical clock and atomic structure measurements. The current accuracy and stability of the lattice clock are also discussed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2007•9 citations

SR OPTICAL CLOCK WITH HIGH STABILITY AND ACCURACY

Andrew D. Ludlow, Sebastian Blatt, M. BOYD +12 more

We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16

Laser Spectroscopy•Apr 1, 2008•0 citations
All-polarization-maintaining, single-port Er:fiber combs offer long-term robust operation as well as high stability. We have built two such combs and evaluated the transfer noise for linking optical clocks. A uniformly broadened spectrum over 135–285 THz with a high signal-to-noise ratio enables the optical frequency measurement of the subharmonics of strontium, ytterbium, and mercury optical lattice clocks with the fractional frequency-noise power spectral density of (1–2) × 10 −17 Hz −1/2 at 1 Hz. By applying a synchronous clock comparison, the comb enables clock ratio measurements with 10 −17 instability at 1 s, which is one order of magnitude smaller than the best instability of the frequency ratio of optical lattice clocks.
We present an optical frequency comb-based scheme that transfers 4.5 × 10−16fractional frequency stability from a 1062 nm wavelength laser to a 1542 nm laser. We demonstrate that this scheme does not hinder the transfer down to 3 × 10−18at 1 s, one order of magnitude better than previous reported result. This exceeds, by more than one order of magnitude, the stability of any optical oscillator demonstrated to date, and satisfies the stability requirement for quantum projection noise-limited optical lattice clocks. We will finally describe our latest efforts to apply this technique for improving the performance the LNE-SYRTE Sr-based optical lattice clocks.
Results from the JILA optical lattice clock are presented. We report on our development of precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 times 1014) of lattice confined strontium atoms is used for both a high-performance optical clock and atomic structure measurements. The current accuracy and stability of the lattice clock are also discussed.
We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16