Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer series on atomic, optical, and plasma physics

Penning Trap Concept and Implementation

Manuel Vogel

Published Jan 1, 2018• 1 citation
Publisher
DOI
10.1007/978-3-319-76264-7_2

Related papers

Penning Trap Implementation

Manuel Vogel

Springer series on atomic, optical, and plasma physics•Jan 1, 2024•0 citations

Fast adiabatic transport of single laser-cooled 9Be+ ions in a cryogenic Penning trap stack

Teresa Meiners, Julia A. Coenders, Johannes Brombacher +4 more

Abstract High precision mass and g-factor measurements in Penning traps have enabled groundbreaking tests of fundamental physics. The most advanced setups use multi-trap methods, which employ transport of particles between specialized trap zones. Present developments focused on the implementation of sympathetic laser cooling will enable significantly shorter duty cycles and better accuracies in many of these scenarios. To take full advantage of these increased capabilities, we implement fast adiabatic transport concepts developed in the context of trapped-ion quantum information processing in a cryogenic Penning trap system. We show adiabatic transport of a single $$^9\textrm{Be}^+$$ 9 Be + ion initially cooled to 2 mK over a 2.2-cm distance within 15 ms and with less than 10 mK energy gain at a peak velocity of 3 m/s. These results represent an important step towards the implementation of quantum logic spectroscopy in the (anti-)proton system. Applying these developments to other multi-trap systems has the potential to considerably increase the data-sampling rate in these experiments.

arXiv:2309.06776•The European Physical Journal Plus•Mar 15, 2024•7 citations

A planar Penning trap

S. Ståhl, Fernando Galve, Joseba Alonso +6 more

The European Physical Journal D•Dec 6, 2004•76 citations

Preparation and Investigation of Highly Charged Ions in a Penning Trap for the Determination of Atomic Magnetic Moments

M. Wiesel

The ARTEMIS experiment aims at measuring magnetic moments of electrons bound in highly charged ions that are stored in a Penning trap. It will provide access to effects of quantum electrodynamics (QED) in the extreme fields close to an ionic nucleus. Additionally, due to the high magnetic field of the Penning trap, higher-order Zeeman effects can be examined and therefore provide a different access to the theory of QED. In this work, a cooled cloud of boron-like argon ions, Ar13+, was prepared in the creation part of a double Penning trap held at cryogenic temperatures. Systematic measurements were carried out in order to investigate the creation trap and its specific parameters to generate a suitable ion cloud. This ion cloud consisted after further charge breeding of different charge states. It was then cooled and parts of it were excited by the SWIFT-technique and, in combination with fast potential-switching, all ion species except Ar13+ were removed. Together with the successful transport of an ion cloud from the creation trap into the spectroscopy trap all concepts necessary in order to prepare an Ar13+ ion cloud for performing laser microwave double-resonance spectroscopy have been implemented. Additionally, a measurement of the modified cyclotron frequency in the creation trap was carried out by exciting the ions radially while detecting their axial motional frequency. Thus, a value for the magnetic field strength in the creation trap with a 5 parts-per-million accuracy was achieved. A system for irradiating microwaves with a frequency of 65 gigahertz onto the position of the ions was developed, characterized and implemented into the apparatus. It was conceptualized for meeting the challenging conditions of the experiment, such as the high magnetic field, the cryogenic temperatures and the difficult geometry. A novel concept of employing an indium tin oxide (ITO)-coated window as an endcap for a closed Penning trap was implemented in the spectroscopy trap and its functionality was proven. The window improves the fluorescence photon efficiency by at least 17% and increases the planarity over the previously used mesh and therefore decreases the trap anharmonicities. Additionally, a test of the ITO-coated window proved its applicability as a Faraday cup for detecting highly charged ions. During this thesis, experimental studies of the various components of ARTEMIS have been carried out and the full apparatus was assembled and put into operation. The focus of this work was the design of the mechanical parts and their assembly, such as the cryogenic concept and the vibrational decoupling. In the future, ARTEMIS will be connected to the HITRAP beamline at GSI, so heaviest highly charged ions can be examined. During this work, a fast opening valve, that separates the trap vacuum from the beamline vacuum, was assembled and initial tests were conducted.

•Jan 1, 2017•0 citations

Ion-photon entanglement and state mapping in an optical cavity

Tracy E. Northup, Andreas Stute, Bernardo Casabone +3 more

At the University of Sussex we are building a coplanar-waveguide (CPW) Penning trap. This is a novel planar Penning trap, which results form the projection of the well-known cylindrical trap onto the surface of a chip [1]. The trap allows for the compensation of electrical anharmonicities up to the sixth order and permits the observation of a single trapped electron, a primary goal not yet achieved with planar Penning trap technology. The electron can be coupled to a distant superconducting coplanar-waveguide resonator, such as those used in circuit-QED with artificial two level systems. The cyclotron motion interacts coherently with the microwave resonator, implementing a system of two coupled quantum harmonic oscillators and with applications in quantum metrology and quantum computation. In the poster, we report on recent experimental progress in the construction of a cryogenic CPW- Penning trap.

Bulletin of the American Physical Society•Jun 6, 2012•0 citations

The tunneling approach

WORLD SCIENTIFIC eBooks•Jul 3, 2018•0 citations
Abstract High precision mass and g-factor measurements in Penning traps have enabled groundbreaking tests of fundamental physics. The most advanced setups use multi-trap methods, which employ transport of particles between specialized trap zones. Present developments focused on the implementation of sympathetic laser cooling will enable significantly shorter duty cycles and better accuracies in many of these scenarios. To take full advantage of these increased capabilities, we implement fast adiabatic transport concepts developed in the context of trapped-ion quantum information processing in a cryogenic Penning trap system. We show adiabatic transport of a single 9Be+^9\textrm{Be}^+9Be+ 9 Be + ion initially cooled to 2 mK over a 2.2-cm distance within 15 ms and with less than 10 mK energy gain at a peak velocity of 3 m/s. These results represent an important step towards the implementation of quantum logic spectroscopy in the (anti-)proton system. Applying these developments to other multi-trap systems has the potential to considerably increase the data-sampling rate in these experiments.
The ARTEMIS experiment aims at measuring magnetic moments of electrons bound in highly charged ions that are stored in a Penning trap. It will provide access to effects of quantum electrodynamics (QED) in the extreme fields close to an ionic nucleus. Additionally, due to the high magnetic field of the Penning trap, higher-order Zeeman effects can be examined and therefore provide a different access to the theory of QED. In this work, a cooled cloud of boron-like argon ions, Ar13+, was prepared in the creation part of a double Penning trap held at cryogenic temperatures. Systematic measurements were carried out in order to investigate the creation trap and its specific parameters to generate a suitable ion cloud. This ion cloud consisted after further charge breeding of different charge states. It was then cooled and parts of it were excited by the SWIFT-technique and, in combination with fast potential-switching, all ion species except Ar13+ were removed. Together with the successful transport of an ion cloud from the creation trap into the spectroscopy trap all concepts necessary in order to prepare an Ar13+ ion cloud for performing laser microwave double-resonance spectroscopy have been implemented. Additionally, a measurement of the modified cyclotron frequency in the creation trap was carried out by exciting the ions radially while detecting their axial motional frequency. Thus, a value for the magnetic field strength in the creation trap with a 5 parts-per-million accuracy was achieved. A system for irradiating microwaves with a frequency of 65 gigahertz onto the position of the ions was developed, characterized and implemented into the apparatus. It was conceptualized for meeting the challenging conditions of the experiment, such as the high magnetic field, the cryogenic temperatures and the difficult geometry. A novel concept of employing an indium tin oxide (ITO)-coated window as an endcap for a closed Penning trap was implemented in the spectroscopy trap and its functionality was proven. The window improves the fluorescence photon efficiency by at least 17% and increases the planarity over the previously used mesh and therefore decreases the trap anharmonicities. Additionally, a test of the ITO-coated window proved its applicability as a Faraday cup for detecting highly charged ions. During this thesis, experimental studies of the various components of ARTEMIS have been carried out and the full apparatus was assembled and put into operation. The focus of this work was the design of the mechanical parts and their assembly, such as the cryogenic concept and the vibrational decoupling. In the future, ARTEMIS will be connected to the HITRAP beamline at GSI, so heaviest highly charged ions can be examined. During this work, a fast opening valve, that separates the trap vacuum from the beamline vacuum, was assembled and initial tests were conducted.
At the University of Sussex we are building a coplanar-waveguide (CPW) Penning trap. This is a novel planar Penning trap, which results form the projection of the well-known cylindrical trap onto the surface of a chip [1]. The trap allows for the compensation of electrical anharmonicities up to the sixth order and permits the observation of a single trapped electron, a primary goal not yet achieved with planar Penning trap technology. The electron can be coupled to a distant superconducting coplanar-waveguide resonator, such as those used in circuit-QED with artificial two level systems. The cyclotron motion interacts coherently with the microwave resonator, implementing a system of two coupled quantum harmonic oscillators and with applications in quantum metrology and quantum computation. In the poster, we report on recent experimental progress in the construction of a cryogenic CPW- Penning trap.