Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Preparation and Investigation of Highly Charged Ions in a Penning Trap for the Determination of Atomic Magnetic Moments

M. Wiesel

Published Jan 1, 2017• 0 citations
Publisher

Abstract

The ARTEMIS experiment aims at measuring magnetic moments of electrons bound in highly charged ions that are stored in a Penning trap. It will provide access to effects of quantum electrodynamics (QED) in the extreme fields close to an ionic nucleus. Additionally, due to the high magnetic field of the Penning trap, higher-order Zeeman effects can be examined and therefore provide a different access to the theory of QED. In this work, a cooled cloud of boron-like argon ions, Ar13+, was prepared in the creation part of a double Penning trap held at cryogenic temperatures. Systematic measurements were carried out in order to investigate the creation trap and its specific parameters to generate a suitable ion cloud. This ion cloud consisted after further charge breeding of different charge states. It was then cooled and parts of it were excited by the SWIFT-technique and, in combination with fast potential-switching, all ion species except Ar13+ were removed. Together with the successful transport of an ion cloud from the creation trap into the spectroscopy trap all concepts necessary in order to prepare an Ar13+ ion cloud for performing laser microwave double-resonance spectroscopy have been implemented. Additionally, a measurement of the modified cyclotron frequency in the creation trap was carried out by exciting the ions radially while detecting their axial motional frequency. Thus, a value for the magnetic field strength in the creation trap with a 5 parts-per-million accuracy was achieved. A system for irradiating microwaves with a frequency of 65 gigahertz onto the position of the ions was developed, characterized and implemented into the apparatus. It was conceptualized for meeting the challenging conditions of the experiment, such as the high magnetic field, the cryogenic temperatures and the difficult geometry. A novel concept of employing an indium tin oxide (ITO)-coated window as an endcap for a closed Penning trap was implemented in the spectroscopy trap and its functionality was proven. The window improves the fluorescence photon efficiency by at least 17% and increases the planarity over the previously used mesh and therefore decreases the trap anharmonicities. Additionally, a test of the ITO-coated window proved its applicability as a Faraday cup for detecting highly charged ions. During this thesis, experimental studies of the various components of ARTEMIS have been carried out and the full apparatus was assembled and put into operation. The focus of this work was the design of the mechanical parts and their assembly, such as the cryogenic concept and the vibrational decoupling. In the future, ARTEMIS will be connected to the HITRAP beamline at GSI, so heaviest highly charged ions can be examined. During this work, a fast opening valve, that separates the trap vacuum from the beamline vacuum, was assembled and initial tests were conducted.

DOI
10.26083/tuprints-00006280

Related papers

Towards Laser Cooling of Beryllium Ions at the Alphatrap Experiment

Sandro Kraemer

Alphatrap is a Penning-trap experiment aiming for the test of bound-state quantum electrodynamics (QED) by measuring the g-factor of electrons bound in highly charged ions up to hydrogen-like 208Pb81+. The high atomic number Z allows a test of boundstate QED under highest field strengths. Cold ions are necessary for high-precision measurements revealing the small additional effect of QED. As a novel development, laser cooling of beryllium ions will be used to sympathetically cool highly charged ions. The lower achievable temperatures are expected to further increase the precision of the measurement. Additionally, new measurement schemes such as simultaneous g-factor measurements on Coulomb crystallized ion pairs become feasible. In the context of this thesis, a concept for implementation of laser cooling at the Alphatrap experiment using 313nm light was developed. The experiment specific requirements on laser cooling in a Penning trap and sympathetic cooling are discussed and the results of the commissioning of the laser system are presented.

•Jan 1, 2017•0 citations

Development of a Pulse-Tube-Cooled, Cryogenic, Permanent Magnet Trap for Laser Cooling at μTEx

P. Justus

A direct, high-precision measurement of the 3He2+ nuclear magnetic moment in a Penning trap will provide the most accurate calibration of 3He probes for nuclear magnetic resonance. The magnetic moment measurement at μTEx is carried out using the so-called continuous Stern-Gerlach effect, in which the spin state of the trapped ion is determined via axial frequency shifts in an inhomogeneous magnetic field. However, its mass and small magnetic moment lead to difficulties in determining the spin state, as the axial frequency shifts are on the order of background frequency fluctuations. These fluctuations can be reduced by lowering the energy of the trapped ion. Since traditional resistive cooling is not sufficient, and a bare helium nucleus cannot be laser cooled directly to reduce its energy, sympathetic cooling of 3He2+ is a well-suited technique. It is achieved by coupling the nucleus to a cloud of Doppler-cooled 9Be+ ions - produced by laser ablation from a solid target - in a coupling trap. To characterise laser cooling of 9Be+ at its 2S1/2 →2 P3/2 transition and to test the available coupling trap, a new cryogenic Penning-trap experiment at μTEx is currently being developed. The experiment uses a pair of Penning traps coupled together over their endcaps forming the coupling trap for sympathetic laser cooling of 3He2+ with 9Be+. The setup, developed and characterized within this thesis, utilises a pulse-tube cooler to reach cryogenic temperatures of 4 K and a permanent magnet capable of generating a magnetic field of 240 mT, with the B2 parameter between ±2 T/m2 over a distance of 5 mm, and 0.75 T/m2 at the trap centre. The choice of a pulse tube cooler and permanent magnet makes the experiment capable of supporting frequent cooling cycles and quick changes. Initially, the experiment is supposed to test the coupling traps and to characterise laser cooling of 9Be+ ions, and in future, offer an adjustable platform for further testing of new components related to high-precision experiments in Penning traps.

•Aug 1, 2025•0 citations

A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions

T. Leopold, S. A. King, P. Micke +5 more

A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.

arXiv:1901.03082•Review of Scientific Instruments•Jul 1, 2019•55 citations

Quantum dynamics of small numbers of ions in a penning trap

G. Stutter

Laser-cooled trapped ions are one of the main systems used in experiments in the fields of quantum optics and quantum information. There are two commonly-used types of ion trap, the radiofrequency trap and the Penning trap. In general, the RF trap has been more widely used in quantum information experiments, meaning that the set of experimental tools for conducting these types of experiments in a Penning trap is currently less complete. The aim of the work presented in this thesis is to increase this array of tools. Our experiment uses 40Ca+ ions in a Penning trap alongside lasers. Spectroscopy has been performed on single Doppler cooled ions, and on ions that have been prepared close to their ground state of motion using a multiple-stage sideband cooling technique resulting in an average phonon occupation number of $\nzbar = 0.029\pm 0.011$ from an initial $\nzbar \approx 24$. This corresponds to a quantum ground state population of $97\%$, which is close to the sideband cooling limit in our system. An axial heating rate measurement of $\dot{\bar{n}}_z=\SI{0.56\pm0.52}{\per\second}$ has also been obtained, which is the lowest recorded to date, due in part to the large dimensions of our trap. Additionally improved control of the Penning trap radial motion has been demonstrated and the average phonon occupation number of the modified cyclotron motion has been reduced from $\ncbar\approx150$ after Doppler cooling to $\ncbar=0.6$ after sideband cooling. Some preliminary single-ion coherent operations have also been performed. In the future we hope that this system of ground state cooled ions in a Penning trap can be used to generate highly-entangled states in two or more ions, with a view to performing simple quantum error-correcting codes and eventually an analogue quantum simulation of spin systems.

•Nov 1, 2015•1 citation

Investigation of a Novel Method for Sympathetic Laser Cooling of Highly Charged Ions in a Penning Trap

F.J.W. Hahne

The Penning trap experiment Alphatrap tests quantum electrodynamics via g- factor measurements of bound electrons in highly charged ions (HCI). The precision of the measurements can be improved by cooling the HCI. This thesis describes a novel and versatile method to sympathetically cool HCIs with laser-cooled beryllium ions efficiently in high-precision Penning traps. The method is based on increasing the coupling of two ions stored in separate penning traps by adding an electrical tank circuit. In a proof of principle measurement this was demonstrated using a 84Kr23+ and 40Ar11+ ion: first, we saw an avoided crossing of the ion modes, and second, we showed a Rabi oscillation in the energy transfer. Our coupling technique enables active control of the coupling strength between the ions, so that a coupling time of τ = 0:856(16) s was achieved. We see this as a possible tool to efficiently cool a wide range of ion species. In addition, an active beam stabilization system was installed to reduce fluctuations of the cooling laser beam position and orientation, and to improve the alignment of the laser with respect to the beryllium ions. This system was calibrated and geometric losses of the laser transmission through our Penning trap setup were estimated.

•Jan 1, 2020•0 citations

Detection Electronics Design and First Observation of Bound-Electron Spin Transitions at the ALPHATRAP g-Factor Experiment

Weigel, Andreas

ALPHATRAP is a Penning-trap based experiment located at the Max-Planck-Institut für Kernphysik (MPIK). It is dedicated to the exploration of ground-state properties of heavy, highly charged ions (HCI). The major goal of the ALPHATRAP \nexperiment are high precision measurements of the bound-electron g-factor. The comparison of the experimental result with recent theoretical calculations will not only serve as a sensitive test of bound-state quantum electrodynamics (BS-QED) but also yields a new approach for the determination of fundamental constants such as the electron mass or the fine structure constant. The measurement of the bound-electron g-factor of a single HCI is performed in an optimized cryogenic double Penning-trap setup, utilizing the continuous Stern-Gerlach effect. For injection of externally produced HCI up to 208Pb81+ the ALPHATRAP experiment is \ncoupled to various ion sources, including the Heidelberg Electron-Beam Ion Trap. \nThis thesis describes the setup and preparation of the ALPHATRAP experiment on its way towards its first g-factor measurement. In this context a new highly sensitive detection system was implemented and successfully tested. This enabled a first commissioning of the whole apparatus with in situ generated HCI as well as HCI injected through the room temperature beamline. The first-time integration \nof an externally operable cryogenic valve allowed for excellent vacuum conditions with long ion storage times. The implementation of typical ion detection and manipulation techniques was demonstrated by characterization measurements of the detection system and the trapping fields. The commissioning culminated in the first direct observation of induced bound-electron spin transitions at the \nALPHATRAP experiment.

Ruprecht-Karls-Universität Heidelberg eBooks•Jan 1, 2019•1 citation
The ARTEMIS experiment aims at measuring magnetic moments of electrons bound in highly charged ions that are stored in a Penning trap. It will provide access to effects of quantum electrodynamics (QED) in the extreme fields close to an ionic nucleus. Additionally, due to the high magnetic field of the Penning trap, higher-order Zeeman effects can be examined and therefore provide a different access to the theory of QED. In this work, a cooled cloud of boron-like argon ions, Ar13+, was prepared in the creation part of a double Penning trap held at cryogenic temperatures. Systematic measurements were carried out in order to investigate the creation trap and its specific parameters to generate a suitable ion cloud. This ion cloud consisted after further charge breeding of different charge states. It was then cooled and parts of it were excited by the SWIFT-technique and, in combination with fast potential-switching, all ion species except Ar13+ were removed. Together with the successful transport of an ion cloud from the creation trap into the spectroscopy trap all concepts necessary in order to prepare an Ar13+ ion cloud for performing laser microwave double-resonance spectroscopy have been implemented. Additionally, a measurement of the modified cyclotron frequency in the creation trap was carried out by exciting the ions radially while detecting their axial motional frequency. Thus, a value for the magnetic field strength in the creation trap with a 5 parts-per-million accuracy was achieved. A system for irradiating microwaves with a frequency of 65 gigahertz onto the position of the ions was developed, characterized and implemented into the apparatus. It was conceptualized for meeting the challenging conditions of the experiment, such as the high magnetic field, the cryogenic temperatures and the difficult geometry. A novel concept of employing an indium tin oxide (ITO)-coated window as an endcap for a closed Penning trap was implemented in the spectroscopy trap and its functionality was proven. The window improves the fluorescence photon efficiency by at least 17% and increases the planarity over the previously used mesh and therefore decreases the trap anharmonicities. Additionally, a test of the ITO-coated window proved its applicability as a Faraday cup for detecting highly charged ions. During this thesis, experimental studies of the various components of ARTEMIS have been carried out and the full apparatus was assembled and put into operation. The focus of this work was the design of the mechanical parts and their assembly, such as the cryogenic concept and the vibrational decoupling. In the future, ARTEMIS will be connected to the HITRAP beamline at GSI, so heaviest highly charged ions can be examined. During this work, a fast opening valve, that separates the trap vacuum from the beamline vacuum, was assembled and initial tests were conducted.
Alphatrap is a Penning-trap experiment aiming for the test of bound-state quantum electrodynamics (QED) by measuring the g-factor of electrons bound in highly charged ions up to hydrogen-like 208Pb81+. The high atomic number Z allows a test of boundstate QED under highest field strengths. Cold ions are necessary for high-precision measurements revealing the small additional effect of QED. As a novel development, laser cooling of beryllium ions will be used to sympathetically cool highly charged ions. The lower achievable temperatures are expected to further increase the precision of the measurement. Additionally, new measurement schemes such as simultaneous g-factor measurements on Coulomb crystallized ion pairs become feasible. In the context of this thesis, a concept for implementation of laser cooling at the Alphatrap experiment using 313nm light was developed. The experiment specific requirements on laser cooling in a Penning trap and sympathetic cooling are discussed and the results of the commissioning of the laser system are presented.
A direct, high-precision measurement of the 3He2+ nuclear magnetic moment in a Penning trap will provide the most accurate calibration of 3He probes for nuclear magnetic resonance. The magnetic moment measurement at μTEx is carried out using the so-called continuous Stern-Gerlach effect, in which the spin state of the trapped ion is determined via axial frequency shifts in an inhomogeneous magnetic field. However, its mass and small magnetic moment lead to difficulties in determining the spin state, as the axial frequency shifts are on the order of background frequency fluctuations. These fluctuations can be reduced by lowering the energy of the trapped ion. Since traditional resistive cooling is not sufficient, and a bare helium nucleus cannot be laser cooled directly to reduce its energy, sympathetic cooling of 3He2+ is a well-suited technique. It is achieved by coupling the nucleus to a cloud of Doppler-cooled 9Be+ ions - produced by laser ablation from a solid target - in a coupling trap. To characterise laser cooling of 9Be+ at its 2S1/2 →2 P3/2 transition and to test the available coupling trap, a new cryogenic Penning-trap experiment at μTEx is currently being developed. The experiment uses a pair of Penning traps coupled together over their endcaps forming the coupling trap for sympathetic laser cooling of 3He2+ with 9Be+. The setup, developed and characterized within this thesis, utilises a pulse-tube cooler to reach cryogenic temperatures of 4 K and a permanent magnet capable of generating a magnetic field of 240 mT, with the B2 parameter between ±2 T/m2 over a distance of 5 mm, and 0.75 T/m2 at the trap centre. The choice of a pulse tube cooler and permanent magnet makes the experiment capable of supporting frequent cooling cycles and quick changes. Initially, the experiment is supposed to test the coupling traps and to characterise laser cooling of 9Be+ ions, and in future, offer an adjustable platform for further testing of new components related to high-precision experiments in Penning traps.
A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.
Laser-cooled trapped ions are one of the main systems used in experiments in the fields of quantum optics and quantum information. There are two commonly-used types of ion trap, the radiofrequency trap and the Penning trap. In general, the RF trap has been more widely used in quantum information experiments, meaning that the set of experimental tools for conducting these types of experiments in a Penning trap is currently less complete. The aim of the work presented in this thesis is to increase this array of tools. Our experiment uses 40Ca+ ions in a Penning trap alongside lasers. Spectroscopy has been performed on single Doppler cooled ions, and on ions that have been prepared close to their ground state of motion using a multiple-stage sideband cooling technique resulting in an average phonon occupation number of $\nzbar = 0.029\pm 0.011$ from an initial $\nzbar \approx 24$. This corresponds to a quantum ground state population of 97%97\%97%, which is close to the sideband cooling limit in our system. An axial heating rate measurement of $\dot{\bar{n}}_z=\SI{0.56\pm0.52}{\per\second}$ has also been obtained, which is the lowest recorded to date, due in part to the large dimensions of our trap. Additionally improved control of the Penning trap radial motion has been demonstrated and the average phonon occupation number of the modified cyclotron motion has been reduced from $\ncbar\approx150$ after Doppler cooling to $\ncbar=0.6$ after sideband cooling. Some preliminary single-ion coherent operations have also been performed. In the future we hope that this system of ground state cooled ions in a Penning trap can be used to generate highly-entangled states in two or more ions, with a view to performing simple quantum error-correcting codes and eventually an analogue quantum simulation of spin systems.
The Penning trap experiment Alphatrap tests quantum electrodynamics via g- factor measurements of bound electrons in highly charged ions (HCI). The precision of the measurements can be improved by cooling the HCI. This thesis describes a novel and versatile method to sympathetically cool HCIs with laser-cooled beryllium ions efficiently in high-precision Penning traps. The method is based on increasing the coupling of two ions stored in separate penning traps by adding an electrical tank circuit. In a proof of principle measurement this was demonstrated using a 84Kr23+ and 40Ar11+ ion: first, we saw an avoided crossing of the ion modes, and second, we showed a Rabi oscillation in the energy transfer. Our coupling technique enables active control of the coupling strength between the ions, so that a coupling time of τ = 0:856(16) s was achieved. We see this as a possible tool to efficiently cool a wide range of ion species. In addition, an active beam stabilization system was installed to reduce fluctuations of the cooling laser beam position and orientation, and to improve the alignment of the laser with respect to the beryllium ions. This system was calibrated and geometric losses of the laser transmission through our Penning trap setup were estimated.
ALPHATRAP is a Penning-trap based experiment located at the Max-Planck-Institut für Kernphysik (MPIK). It is dedicated to the exploration of ground-state properties of heavy, highly charged ions (HCI). The major goal of the ALPHATRAP \nexperiment are high precision measurements of the bound-electron g-factor. The comparison of the experimental result with recent theoretical calculations will not only serve as a sensitive test of bound-state quantum electrodynamics (BS-QED) but also yields a new approach for the determination of fundamental constants such as the electron mass or the fine structure constant. The measurement of the bound-electron g-factor of a single HCI is performed in an optimized cryogenic double Penning-trap setup, utilizing the continuous Stern-Gerlach effect. For injection of externally produced HCI up to 208Pb81+ the ALPHATRAP experiment is \ncoupled to various ion sources, including the Heidelberg Electron-Beam Ion Trap. \nThis thesis describes the setup and preparation of the ALPHATRAP experiment on its way towards its first g-factor measurement. In this context a new highly sensitive detection system was implemented and successfully tested. This enabled a first commissioning of the whole apparatus with in situ generated HCI as well as HCI injected through the room temperature beamline. The first-time integration \nof an externally operable cryogenic valve allowed for excellent vacuum conditions with long ion storage times. The implementation of typical ion detection and manipulation techniques was demonstrated by characterization measurements of the detection system and the trapping fields. The commissioning culminated in the first direct observation of induced bound-electron spin transitions at the \nALPHATRAP experiment.