Applied Physics Letters

Coherent population trapping atomic clock by phase modulation for wide locking range

Yuichiro Yano, Masatoshi Kajita, T. Ido, Motoaki Hara

Published Nov 13, 2017• 15 citations
Publisher

Abstract

A method of detecting Coherent Population Trapping resonance by phase modulation (PM) was studied to expand the frequency locking range (LR). We calculated error signals by density matrix analysis using an eigenvector algorithm and verified the calculated result using an 87Rb vapor cell and a Rb-D1 vertical cavity surface-emitting laser. By comparing the error signal for PM with that for conventional frequency modulation (FM), it was found that the LR with PM is one order of magnitude wider than that with FM without degrading the frequency stability.

DOI
10.1063/1.4991560

Related papers

Theoretical and experimental study of Rb coherent population trapping atomic clock with phase modulation detection

Yuichiro Yano, Motoaki Hara, Masatoshi Kajita +1 more

We theoretically and experimentally study Coherent Population Trapping (CPT) resonance with phase modulation detection. We measured the time response behavior of CPT resonance using an87Rb gas cell and the D1-line vertical-cavity surface-emitting laser(VCSEL) and calculated the periodic behavior of the density matrix based on eigenvector algorithm. Experiment results are good agreement with calculation results.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

Passive atomic frequency standard based on coherent population trapping in ^87Rb using injection-locked lasers

Han Seb Moon, Sang Eon Park, Young‐Ho Park +2 more

We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.

Journal of the Optical Society of America B•Nov 1, 2006•23 citations

Frequency locking: A distinctive feature of the coherent population trapping

Eugene A. Tsygankov, Dmitry S. Chuchelov, Maria I. Vaskovskaya +3 more

We investigate the use of phase modulation to generate an error signal for frequency stabilization to a reference atomic transition. The study focuses on the high-frequency modulation regime. Our theoretical analysis shows that, in the case of coherent population trapping, the maximal slope of the error signal remains constant as the modulation frequency increases, whereas it steadily decreases for other types of resonances. Experimental results with 87Rb atoms confirm this behavior under comparison with the double radio-optical resonance.

Journal of Applied Physics•Mar 12, 2025•4 citations

Stabilization method for atomic clocks to detect the maximum coherent-population-trapping resonance signal

Yusuke Odagiri, Satoshi Hatano, Yuichiro Yano +3 more

Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.

Japanese Journal of Applied Physics•Jun 1, 2025•2 citations

Comparison of field shifts in an atomic clock based on the effect of coherent population trapping in 87Rb atoms under modulation of laser pump current at frequencies of 3.4 and 6.8 GHz

S M Ignatovich, Mikhail N Skvortsov, I. S. Mesenzova +4 more

Abstract Experimental parameters of the resonance of coherent population trapping (CTP) on D1 line in 87Rb and light shifts are compared under modulation of the laser pump current at frequencies of 3.4 and 6.8 GHz. Reproducibility of the parameters of a laser with a vertical cavity needed for long-term stability of an atomic clock is considered. The instabilities of atomic CPT-clock obtained for 1 s are 1.2 × 10−11 and 3 × 10−12 for frequencies of 3.4 GHz and 6.8 GHz, respectively.

Quantum Electronics•Mar 30, 2022•1 citation

Optimization of FM spectroscopy parameters for a frequency locking loop in small scale CPT based atomic clocks

Ido Ben-Aroya, Matan Kahanov, G. Eisenstein

We describe the optimization of a Frequency Locked Loop (FLL) in an atomic clock which is based on Coherent Population Trapping (CPT) in (87)Rb vapor using the D(2) transition. The FLL uses frequency modulation (FM) spectroscopy and we study the effect of FM parameters (modulation frequency and index) on the sensitivity and the signal to noise ratio of the feedback signal in the FLL. The clock which employs a small spherical glass cell containing (87)Rb atoms and a buffer gas, exhibits a short term stability of 3x10(-11)/ radicaltau. The long term relative frequency stability of the 10 MHz output is better than 10(-10) with a drift of 10(-11) per day.

Optics Express•Jan 1, 2007•18 citations
A method of detecting Coherent Population Trapping resonance by phase modulation (PM) was studied to expand the frequency locking range (LR). We calculated error signals by density matrix analysis using an eigenvector algorithm and verified the calculated result using an 87Rb vapor cell and a Rb-D1 vertical cavity surface-emitting laser. By comparing the error signal for PM with that for conventional frequency modulation (FM), it was found that the LR with PM is one order of magnitude wider than that with FM without degrading the frequency stability.
We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.
We investigate the use of phase modulation to generate an error signal for frequency stabilization to a reference atomic transition. The study focuses on the high-frequency modulation regime. Our theoretical analysis shows that, in the case of coherent population trapping, the maximal slope of the error signal remains constant as the modulation frequency increases, whereas it steadily decreases for other types of resonances. Experimental results with 87Rb atoms confirm this behavior under comparison with the double radio-optical resonance.
Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.
We describe the optimization of a Frequency Locked Loop (FLL) in an atomic clock which is based on Coherent Population Trapping (CPT) in (87)Rb vapor using the D(2) transition. The FLL uses frequency modulation (FM) spectroscopy and we study the effect of FM parameters (modulation frequency and index) on the sensitivity and the signal to noise ratio of the feedback signal in the FLL. The clock which employs a small spherical glass cell containing (87)Rb atoms and a buffer gas, exhibits a short term stability of 3x10(-11)/ radicaltau. The long term relative frequency stability of the 10 MHz output is better than 10(-10) with a drift of 10(-11) per day.