Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Microwave SQUID Multiplexer for Cosmic Microwave Background Imagers

Bradley Dober, Daniel Becker, D. A. Bennett, Sean Bryan, Shannon M. Duff, Johnathon D. Gard, James Prewitt Hays-Wehle, Gene C Hilton, Johannes Hubmayr, C. D. Reintsema, L. R. Vale, Joel N. Ullom

Published Oct 11, 2017• 0 citations
OpenAlex

Abstract

Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($\mu$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $\mu$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density exhibits a white spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the $\mu$MUX as a viable readout technique for future CMB imaging instruments.

Related papers

Microwave SQUID multiplexer demonstration for cosmic microwave background imagers

B. Dober, D. T. Becker, D. A. Bennett +10 more

Key performance characteristics are demonstrated for the microwave SQUID multiplexer (µmux) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the µmux produces a white, input referred current noise level of [Formula: see text] at -77 dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure [Formula: see text] in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e. phonon) noise. Furthermore, the power spectral density is white over a range of frequencies down to ~ 100 mHz, which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the µmux as a viable readout technique for future CMB imaging instruments.

arXiv:1710.04326•Applied Physics Letters•Dec 11, 2017•58 citations

Development of a microwave SQUID multiplexer for superconducting transition-edge sensor bolometer arrays

Zhi-Fa Feng, Xian-Feng Zhou, M Y Li +10 more

Abstract A microwave SQUID multiplexer ( μ MUX) with a high multiplexing factor is a promising readout approach for large-scale superconducting transition-edge sensor (TES) bolometer arrays. This paper reports on the characteristics of 16-channel μ MUX prototype chips and a 60-channel readout module developed to read out TES bolometers for the Ali cosmic microwave background polarization telescope (AliCPT). We designed two different coupling structures between the resonator and the radio-frequency superconducting interference device: design A with a mutual inductance ( M T ) of 2.3 pH and design B with an M T of 6.5 pH. For design A, the mean resonator bandwidth ( Δ f BW ) and peak-to-peak frequency shift ( Δ f pp ) are approximately 610 kHz and 290 kHz, respectively. The measured mean open-loop current noise is less than 40 pA / Hz . Preliminary results indicate that crosstalk between adjacent channels is below 1% in our design A μ MUX chip. A measured channel with design B shows a Δ f BW of 586 kHz and a current noise of 33 pA / Hz , similar to the design A channels. In comparison, the Δ f pp of 803 kHz is much larger than the design A channels due to a larger M T . The readout module, consisting of two design A chips and two design B chips, shows 60 resonances, corresponding to a yield of 94%. In the future, we will place 32 design A channels within the same chip dimension to increase the channel density and build a larger readout module suitable for AliCPT TES arrays.

Superconductor Science and Technology•Sep 1, 2026•0 citations

Readout demonstration of 512 TES bolometers using a single microwave SQUID multiplexer (Conference Presentation)

Bradley Dober, Zeeshan Ahmed, Jason E. Austermann +30 more

To enable the next-generation of bolometric cameras, we are developing the microwave SQUID multiplexer (μMUX). Upcoming receivers such as Simons Observatory, CCAT-prime, BICEP array, Ali-CPT, and CMB-S4 plan to instrument focal planes with 50,000-500,000 sensors. Sensor count is achieved by tiling many 150 mm-diameter densely packed detector arrays into these focal planes. The fabrication and quality of large-format bolometer arrays has been demonstrated and is now mature. In contrast, the readout technology required for next-generation receivers needs development. The sensitivity, low cross-talk, high multiplexing density, and small component size make the μMUX well-suited for this goal. In this approach, the TES signal modulates the inductance of an rf-SQUID that loads a high-Q microwave resonator. The coupled signal therefore modulates the microwave resonance frequency, which may be read out using homodyne techniques. By coupling each resonator to the same microwave feedline, many detectors can be read out on a single coaxial cable pair. The multiplexing density is in practice limited by signal bandwidth, allowable cross-talk, and the digitization bandwidth of room-temperature readout electronics. We present the design and performance of a scalable 64-channel multiplexer chip optimized for bolometric applications. We utilize a new quarter wave resonator design that increases the physical linear density by a factor of two, therefore achieving a smaller footprint for simplified detector packaging. Measurements of this design show 100 kHz resonator bandwidth, uniform 1.8 MHz frequency spacing, and an input referred current noise of 35 pA/√Hz that is well below the level of an optimized, background-limited TES bolometer. Using 8 daisy-chained and frequency scaled chips, we create a 512-channel multiplexer and use it to readout a 512 TES-bolometer array. We present the results of this large-scale μMUX demonstration including system yield, signal cross-talk, and an analysis of noise in various TES bias configurations. The result demonstrates the multiplexing density required to read out 2,000 sensors between 4-8 GHz.

Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XI•Jul 10, 2018•1 citation

A microwave SQUID multiplexer optimized for bolometric applications

B. Dober, Zeeshan Ahmed, K. Arnold +27 more

A microwave superconducting quantum interference device multiplexer has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4–8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4–5 GHz. The median white-noise level is 45 pA/Hz, evaluated at 2 Hz, with a 1/f knee ≤ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is ≤ 0.3%.

arXiv:2010.07998•Applied Physics Letters•Feb 8, 2021•56 citations

Investigation of Large Coupling Between TES X-Ray Microcalorimeter and Microwave Multiplexer Based on Microstrip SQUID

Y. Nakashima, Fuminori Hirayama, Satoshi Kohjiro +5 more

We report on the study of a microwave superconducting quantum interference device (SQUID) multiplexer (MW-Mux) with current noise lower than that of our typical transition-edge sensor (TES) X-ray microcalorimeter. A large mutual inductance, between SQUID loop and input inductor connected to a TES X-ray microcalorimeter in series, realizes such low current noise referred to the SQUID input, but also can cause undesirable resonances which affect the SQUID performances. In this paper, we have developed the MW-Mux with mutual inductance of about 370 pH, which is six times larger than that of the previous one, by adopting a spiral input coil longer than a half wavelength at the readout microwave frequency. Its characteristics are evaluated, and the results have shown that the distortion of the SQUID characteristics and the degradation of its noise performance are not clearly observed. Finally, we have developed an MW-Mux microstrip SQUID with a low current noise of <; 20 pA/√(Hz) which is below the typical noise of our TES X-ray microcalorimeter, 30 pA/√(Hz).

IEEE Transactions on Applied Superconductivity•Mar 21, 2019•8 citations

The Microwave SQUID Multiplexer

J. A. B. Mates

This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.

•Dec 1, 2011•38 citations
Key performance characteristics are demonstrated for the microwave SQUID multiplexer (μ\muμMUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the μ\muμMUX produces a white, input referred current noise level of 29pA/Hz/\sqrt{\mathrm{Hz}}/Hz​ at -77dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98~pA/Hz/\sqrt{\mathrm{Hz}}/Hz​ in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density exhibits a white spectrum at low frequencies (∼\sim∼100mHz), which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the μ\muμMUX as a viable readout technique for future CMB imaging instruments.
Key performance characteristics are demonstrated for the microwave SQUID multiplexer (µmux) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the µmux produces a white, input referred current noise level of [Formula: see text] at -77 dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure [Formula: see text] in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e. phonon) noise. Furthermore, the power spectral density is white over a range of frequencies down to ~ 100 mHz, which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the µmux as a viable readout technique for future CMB imaging instruments.
Abstract A microwave SQUID multiplexer ( μ MUX) with a high multiplexing factor is a promising readout approach for large-scale superconducting transition-edge sensor (TES) bolometer arrays. This paper reports on the characteristics of 16-channel μ MUX prototype chips and a 60-channel readout module developed to read out TES bolometers for the Ali cosmic microwave background polarization telescope (AliCPT). We designed two different coupling structures between the resonator and the radio-frequency superconducting interference device: design A with a mutual inductance ( M T ) of 2.3 pH and design B with an M T of 6.5 pH. For design A, the mean resonator bandwidth ( Δ f BW ) and peak-to-peak frequency shift ( Δ f pp ) are approximately 610 kHz and 290 kHz, respectively. The measured mean open-loop current noise is less than 40 pA / Hz . Preliminary results indicate that crosstalk between adjacent channels is below 1% in our design A μ MUX chip. A measured channel with design B shows a Δ f BW of 586 kHz and a current noise of 33 pA / Hz , similar to the design A channels. In comparison, the Δ f pp of 803 kHz is much larger than the design A channels due to a larger M T . The readout module, consisting of two design A chips and two design B chips, shows 60 resonances, corresponding to a yield of 94%. In the future, we will place 32 design A channels within the same chip dimension to increase the channel density and build a larger readout module suitable for AliCPT TES arrays.
To enable the next-generation of bolometric cameras, we are developing the microwave SQUID multiplexer (μMUX). Upcoming receivers such as Simons Observatory, CCAT-prime, BICEP array, Ali-CPT, and CMB-S4 plan to instrument focal planes with 50,000-500,000 sensors. Sensor count is achieved by tiling many 150 mm-diameter densely packed detector arrays into these focal planes. The fabrication and quality of large-format bolometer arrays has been demonstrated and is now mature. In contrast, the readout technology required for next-generation receivers needs development. The sensitivity, low cross-talk, high multiplexing density, and small component size make the μMUX well-suited for this goal. In this approach, the TES signal modulates the inductance of an rf-SQUID that loads a high-Q microwave resonator. The coupled signal therefore modulates the microwave resonance frequency, which may be read out using homodyne techniques. By coupling each resonator to the same microwave feedline, many detectors can be read out on a single coaxial cable pair. The multiplexing density is in practice limited by signal bandwidth, allowable cross-talk, and the digitization bandwidth of room-temperature readout electronics. We present the design and performance of a scalable 64-channel multiplexer chip optimized for bolometric applications. We utilize a new quarter wave resonator design that increases the physical linear density by a factor of two, therefore achieving a smaller footprint for simplified detector packaging. Measurements of this design show 100 kHz resonator bandwidth, uniform 1.8 MHz frequency spacing, and an input referred current noise of 35 pA/√Hz that is well below the level of an optimized, background-limited TES bolometer. Using 8 daisy-chained and frequency scaled chips, we create a 512-channel multiplexer and use it to readout a 512 TES-bolometer array. We present the results of this large-scale μMUX demonstration including system yield, signal cross-talk, and an analysis of noise in various TES bias configurations. The result demonstrates the multiplexing density required to read out 2,000 sensors between 4-8 GHz.
A microwave superconducting quantum interference device multiplexer has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4–8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4–5 GHz. The median white-noise level is 45 pA/Hz, evaluated at 2 Hz, with a 1/f knee ≤ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is ≤ 0.3%.
We report on the study of a microwave superconducting quantum interference device (SQUID) multiplexer (MW-Mux) with current noise lower than that of our typical transition-edge sensor (TES) X-ray microcalorimeter. A large mutual inductance, between SQUID loop and input inductor connected to a TES X-ray microcalorimeter in series, realizes such low current noise referred to the SQUID input, but also can cause undesirable resonances which affect the SQUID performances. In this paper, we have developed the MW-Mux with mutual inductance of about 370 pH, which is six times larger than that of the previous one, by adopting a spiral input coil longer than a half wavelength at the readout microwave frequency. Its characteristics are evaluated, and the results have shown that the distortion of the SQUID characteristics and the degradation of its noise performance are not clearly observed. Finally, we have developed an MW-Mux microstrip SQUID with a low current noise of <; 20 pA/√(Hz) which is below the typical noise of our TES X-ray microcalorimeter, 30 pA/√(Hz).
This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.