Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

انجمن اپتیک و فوتونیک ایران

Sensitivity improvement of optical pumping atomic magnetometers using Bloch equations

Malihe Ranjbaran, Mohammad mahdi Tehranchi, Seyedeh Mehri Hamidi, S.M.H. Khalkhali

Published Feb 10, 2017• 0 citations
OpenAlex

Related papers

A plateau in the sensitivity of a compact optically pumped atomic magnetometer

Natsuhiko Mizutani, Kazuhisa Okano, Kazuhiro Ban +3 more

In a compact optically pumped atomic magnetometer (OPAM), there is a plateau in the sensitivity where the dependence of the sensitivity on pumping power is small compared with that predicted by the uniform polarization model. The mechanism that generates this plateau was explained by numerical analysis. The distribution of spin polarization in the alkali metal cell of an OPAM was modeled using the Bloch equation incorporating a diffusion term and an equation for the attenuation of the pump beam. The model was well-fitted to the experimental results for a module with a cubic cell with 20 mm sides and pump and probe beams with 8 mm diameter. On the plateau, strong magnetic response was generated at the regions that were not illuminated directly by the intense pump beam, while at the same time spin polarization as large as 0.5 was maintained due to diffusion of the spin-polarized atoms. Thus, the sensitivity of the magnetometer monitored with a probe beam decreases only slightly with increasing pump beam intensity because the spin polarization under an intense pump beam is saturated. This plateau, which is characteristic of this type of magnetometer using a narrow pump and probe beams, can be used in arrays of magnetometers because it enables stable operation with little sensitivity fluctuation from changes in pump beam power.

AIP Advances•May 1, 2014•12 citations

Harmonic detection of magnetic resonance for sensitivity improvement of optical atomic magnetometers

Maliheh Ranjbaran, Mohammad Mehdi Tehranchi, Seyedeh Mehri Hamidi +1 more

Journal of Magnetism and Magnetic Materials•Oct 16, 2016•18 citations

Effect of laser detuning frequency and polarization state on optical pumping efficient

Yuyuan Liu, Qingtao Wang, Chong Kang +2 more

The detecting principle of optical pumping cesium magnetometer sensor used for measurement of geomagnetic field is introduced. The population variation of the Zeeman sublevels with time in the laser-pumped cesium atoms is calculated from the approximate form of the optical Bloch equations, and the effect of laser detuning frequency and polarization state on the populations of Zeeman sublevels in cesium atoms is analyzed in detail. Matlab software is used to emulate the population variation curves in different laser detuning frequency and different polarization state. It is obtained from the curves that the polarization degree of cesium atoms is the most obvious and the optical pumping is the most efficient when the detuning frequency is 0 and the laser is left hand circularly polarized light. It is important to improve the detecting sensitivity and enhance the stability of optical pumping magnetometer sensor.

International Conference on Measurement, Information and Control•May 1, 2012•0 citations

Research of optimal pump light intensity in rubidium atomic magnetometers

Jiajia Li, Ding Zhichao, Zhiguo Wang +2 more

Laser Technology•Jan 1, 2016•0 citations

Optimizations of spin-exchange relaxation-free magnetometer based on potassium and rubidium hybrid optical pumping

Jiancheng Fang, Tao Wang, Hong Zhang +2 more

The hybrid optical pumping atomic magnetometers have not realized its theoretical sensitivity, the optimization is critical for optimal performance. The optimizations proposed in this paper are suitable for hybrid optical pumping atomic magnetometer, which contains two alkali species. To optimize the parameters, the dynamic equations of spin evolution with two alkali species were solved, whose steady-state solution is used to optimize the parameters. The demand of the power of the pump beam is large for hybrid optical pumping. Moreover, the sensitivity of the hybrid optical pumping magnetometer increases with the increase of the power density of the pump beam. The density ratio between the two alkali species is especially important for hybrid optical pumping magnetometer. A simple expression for optimizing the density ratio is proposed in this paper, which can help to determine the mole faction of the alkali atoms in fabricating the hybrid cell before the cell is sealed. The spin-exchange rate between the two alkali species is proportional to the saturated density of the alkali vapor, which is highly dependent on the temperature of the cell. Consequently, the sensitivity of the hybrid optical pumping magnetometer is dependent on the temperature of the cell. We proposed the thermal optimization of the hybrid cell for a hybrid optical pumping magnetometer, which can improve the sensitivity especially when the power of the pump beam is low. With these optimizations, a sensitivity of approximately 5 fT/Hz(1/2) is achieved with gradiometer arrangement.

Review of Scientific Instruments•Dec 1, 2014•41 citations

Research Progress on High Sensitivity and Miniature Optical-Atomic Magnetometer

吴梓楠 Wu Zinan, 赵正钦 Zhao zhengqin, 温钟平 Wen Zhongping +5 more

Laser & Optoelectronics Progress•Jan 1, 2020•4 citations
In a compact optically pumped atomic magnetometer (OPAM), there is a plateau in the sensitivity where the dependence of the sensitivity on pumping power is small compared with that predicted by the uniform polarization model. The mechanism that generates this plateau was explained by numerical analysis. The distribution of spin polarization in the alkali metal cell of an OPAM was modeled using the Bloch equation incorporating a diffusion term and an equation for the attenuation of the pump beam. The model was well-fitted to the experimental results for a module with a cubic cell with 20 mm sides and pump and probe beams with 8 mm diameter. On the plateau, strong magnetic response was generated at the regions that were not illuminated directly by the intense pump beam, while at the same time spin polarization as large as 0.5 was maintained due to diffusion of the spin-polarized atoms. Thus, the sensitivity of the magnetometer monitored with a probe beam decreases only slightly with increasing pump beam intensity because the spin polarization under an intense pump beam is saturated. This plateau, which is characteristic of this type of magnetometer using a narrow pump and probe beams, can be used in arrays of magnetometers because it enables stable operation with little sensitivity fluctuation from changes in pump beam power.
The detecting principle of optical pumping cesium magnetometer sensor used for measurement of geomagnetic field is introduced. The population variation of the Zeeman sublevels with time in the laser-pumped cesium atoms is calculated from the approximate form of the optical Bloch equations, and the effect of laser detuning frequency and polarization state on the populations of Zeeman sublevels in cesium atoms is analyzed in detail. Matlab software is used to emulate the population variation curves in different laser detuning frequency and different polarization state. It is obtained from the curves that the polarization degree of cesium atoms is the most obvious and the optical pumping is the most efficient when the detuning frequency is 0 and the laser is left hand circularly polarized light. It is important to improve the detecting sensitivity and enhance the stability of optical pumping magnetometer sensor.
The hybrid optical pumping atomic magnetometers have not realized its theoretical sensitivity, the optimization is critical for optimal performance. The optimizations proposed in this paper are suitable for hybrid optical pumping atomic magnetometer, which contains two alkali species. To optimize the parameters, the dynamic equations of spin evolution with two alkali species were solved, whose steady-state solution is used to optimize the parameters. The demand of the power of the pump beam is large for hybrid optical pumping. Moreover, the sensitivity of the hybrid optical pumping magnetometer increases with the increase of the power density of the pump beam. The density ratio between the two alkali species is especially important for hybrid optical pumping magnetometer. A simple expression for optimizing the density ratio is proposed in this paper, which can help to determine the mole faction of the alkali atoms in fabricating the hybrid cell before the cell is sealed. The spin-exchange rate between the two alkali species is proportional to the saturated density of the alkali vapor, which is highly dependent on the temperature of the cell. Consequently, the sensitivity of the hybrid optical pumping magnetometer is dependent on the temperature of the cell. We proposed the thermal optimization of the hybrid cell for a hybrid optical pumping magnetometer, which can improve the sensitivity especially when the power of the pump beam is low. With these optimizations, a sensitivity of approximately 5 fT/Hz(1/2) is achieved with gradiometer arrangement.