Journal of Magnetism and Magnetic Materials

Harmonic detection of magnetic resonance for sensitivity improvement of optical atomic magnetometers

Maliheh Ranjbaran, Mohammad Mehdi Tehranchi, Seyedeh Mehri Hamidi, S.M.H. Khalkhali

Published Oct 16, 2016• 19 citations
Publisher
DOI
10.1016/j.jmmm.2016.10.058

Related papers

Relaxation time dependencies of optically detected magnetic resonance harmonics in highly sensitive Mx magnetometers

Maliheh Ranjbaran, Mohammad Mehdi Tehranchi, Seyedeh Mehri Hamidi +1 more

Journal of Magnetism and Magnetic Materials•Sep 8, 2018•15 citations

Spin-Damping in an Ultra-Sensitive Tunable RF Atomic Magnetometer

Orang Alem

Optically pumped radio frequency (RF) atomic magnetometers have been shown to have an improved sensitivity over standard tuned coils for frequencies less than 50 MHz, making these RF magnetometers attractive for the detection of nuclear quadrupole resonance (NQR) and low-field nuclear magnetic resonance (NMR) signals. In an atomic magnetometer a linearly polarized probe beam measures, through Faraday rotation, the transverse atomic magnetization induced by the resonant RF signal. The resonance, or Larmor, frequency of the magnetometer is easily tuned with a small magnetic field. We construct an atomic magnetometer based on a potassium vapor cell with a measured sensitivity of 0.22 ± 0.02 fT/ √ Hz and a detection bandwidth of 334 ± 11 Hz when tuned to 423 kHz, giving a Q of over 1200. While high Q magnetometers are sensitive to weak magnetic fields, they are also sensitive to magnetic transients, such as those associated with the excitation pulses needed for magnetic resonance. The ringing created by such transients can obscure the signal of interest. This is particularly detrimental for magnetic resonance signals that decay faster than the transverse relaxation rate. We demonstrate that by feeding back part of the optical signal to orthogonal electromagnetic coils, this unwanted ringing can be quickly damped out leaving the magnetometer ready for the detection of the signal. This negative feedback as applied to the K spins is called spin-damping and can be used to relax the K atoms faster by more than two orders of magnitude. Using spin-damping we reduce the dead-time before data acquisition from 0.8 to 0.2 ms in the detection of NQR signals from ammonium nitrate, one of the so-called fertilizer bomb explosives with an NQR frequency of 423 kHz. Furthermore, we discover that spin-damping can not only be used to suppress signals, it can also be used to suppress noise. We show that it can be used to suppress both environmental noise and more fundamental quantum noise, such as photon shot and spin projection noise. The latter suppression opens the door for its use in quantum control to initialize spin systems before measurements. For phase-sensitive detection, as is often used in magnetic resonance, spin-damping suppresses signal and noise in such a way as to increase the sensitivity bandwidth of the magnetometer. We prove, both theoretically and experimentally, that it is possible to increase the magnetometer detection bandwidth by a factor of 3 or more without significant loss in sensitivity. Such gains in bandwidth for a high Q magnetometer translate into savings in detection time, particularly for substance detection where the frequency of the signal of interest may not be completely known.

•Aug 18, 2011•1 citation

Microfabricated Spin Polarized Atomic Magnetometers

Ricardo Jiménez-Martínez

Spin polarized atomic magnetometers involve the preparation of atomic spins and their detection for monitoring magnetic fields. Due to the fact that magnetic fields are ubiquitous in our world, spin polarized atomic magnetometers are used in a wide range of applications from the detection of magnetic fields generated by the human heart and brain to the detection of nuclear magnetic resonance. In this thesis we developed microfabricated spin polarized atomic magnetometers. These sensors are based on optical pumping and spin-exchange collisions between alkali atoms and noble gases contained in microfabricated millimeter-scale vapor cells. In the first part of the thesis, we improved different features of current microfabricated optical magnetometers. Specifically, we improved the bandwidth of these devices, without degrading their magnetic field sensitivity, by broadening their magnetic resonance through spin-exchange collisions between alkali atoms. We also implemented all-optical excitation techniques to avoid problems, such as the magnetic perturbation of the environment, induced by the radio-frequency fields used in some of these sensors. In the second part of the thesis we demonstrated a microfluidic chip for the optical production and detection of hyperpolarized Xe gas through spin-exchange collisions with optically pumped Rb atoms. These devices are critical for the widespread use of spin polarized atomic magnetometers in applications requiring simple, compact, low-cost, and portable instrumentation.

•Jan 1, 2013•2 citations

Research Progress on High Sensitivity and Miniature Optical-Atomic Magnetometer

吴梓楠 Wu Zinan, 赵正钦 Zhao zhengqin, 温钟平 Wen Zhongping +5 more

Laser & Optoelectronics Progress•Jan 1, 2020•4 citations

Improving the sensitivity of an optically pumped rubidium atomic magnetometer by using of a repumping laser beam

Lulu Zhang, Le-Le Bai, Yu-Lin Yang +5 more

For the experimental implementation of an optically pumped atomic magnetometer, the magnetic resonance signal with a narrow linewidth and a high signal-to-noise ratio (SNR) is required for achieving a high sensitivity. Using 795-nm laser as both the pumping and the probe laser, we compare the magnetic resonance signals from different rubidium atomic vapor cells and investigate the variations of magnetic resonance signals with temperature. Optimized magnetic resonance signal is achieved with a paraffin-coated rubidium atomic vapor cell. Then the 780-nm laser at rubidium D2 line is introduced as a repumping laser, and we explore the changes of linewidth and SNR of the magnetic resonance signal under different power of the pumping laser and the repumping laser. Owing to the 780-nm repumping laser beam, the signal amplitude of rubidium-85 magnetic resonance signal is improved remarkably because more rubidium-85 atoms are spin- polarized by the 795-nm pumping laser beam. At the same time, the linewidth of rubidium-85 magnetic resonance signal is roughly not broadened anymore. We realize a closed-loop optically pumped rubidium-85 atomic magnetometer with a bandwidth of ~1.2 kHz, and the sensitivity is calibrated to be ~245.5 pT/Hz1/2 only with the 795-nm pumping laser beam. Owing to the employment of the 780-nm repumping laser beam, the sensitivity is improved to be ~26.4 pT/Hz1/2 which is improved roughly by one order of magnitude. We also calibrate the measurement accuracy and deviation of a commercial fluxgate magnetometer by using the enhanced rubidium magnetic resonance signal.

Acta Physica Sinica•Jan 1, 2021•5 citations

Magnetic Resonance Based Atomic Magnetometers

Antoine Weis, G. Bison, Z. D. Grujić

Smart sensors, measurement and instrumentation•Sep 20, 2016•26 citations
Optically pumped radio frequency (RF) atomic magnetometers have been shown to have an improved sensitivity over standard tuned coils for frequencies less than 50 MHz, making these RF magnetometers attractive for the detection of nuclear quadrupole resonance (NQR) and low-field nuclear magnetic resonance (NMR) signals. In an atomic magnetometer a linearly polarized probe beam measures, through Faraday rotation, the transverse atomic magnetization induced by the resonant RF signal. The resonance, or Larmor, frequency of the magnetometer is easily tuned with a small magnetic field. We construct an atomic magnetometer based on a potassium vapor cell with a measured sensitivity of 0.22 ± 0.02 fT/ √ Hz and a detection bandwidth of 334 ± 11 Hz when tuned to 423 kHz, giving a Q of over 1200. While high Q magnetometers are sensitive to weak magnetic fields, they are also sensitive to magnetic transients, such as those associated with the excitation pulses needed for magnetic resonance. The ringing created by such transients can obscure the signal of interest. This is particularly detrimental for magnetic resonance signals that decay faster than the transverse relaxation rate. We demonstrate that by feeding back part of the optical signal to orthogonal electromagnetic coils, this unwanted ringing can be quickly damped out leaving the magnetometer ready for the detection of the signal. This negative feedback as applied to the K spins is called spin-damping and can be used to relax the K atoms faster by more than two orders of magnitude. Using spin-damping we reduce the dead-time before data acquisition from 0.8 to 0.2 ms in the detection of NQR signals from ammonium nitrate, one of the so-called fertilizer bomb explosives with an NQR frequency of 423 kHz. Furthermore, we discover that spin-damping can not only be used to suppress signals, it can also be used to suppress noise. We show that it can be used to suppress both environmental noise and more fundamental quantum noise, such as photon shot and spin projection noise. The latter suppression opens the door for its use in quantum control to initialize spin systems before measurements. For phase-sensitive detection, as is often used in magnetic resonance, spin-damping suppresses signal and noise in such a way as to increase the sensitivity bandwidth of the magnetometer. We prove, both theoretically and experimentally, that it is possible to increase the magnetometer detection bandwidth by a factor of 3 or more without significant loss in sensitivity. Such gains in bandwidth for a high Q magnetometer translate into savings in detection time, particularly for substance detection where the frequency of the signal of interest may not be completely known.
Spin polarized atomic magnetometers involve the preparation of atomic spins and their detection for monitoring magnetic fields. Due to the fact that magnetic fields are ubiquitous in our world, spin polarized atomic magnetometers are used in a wide range of applications from the detection of magnetic fields generated by the human heart and brain to the detection of nuclear magnetic resonance. In this thesis we developed microfabricated spin polarized atomic magnetometers. These sensors are based on optical pumping and spin-exchange collisions between alkali atoms and noble gases contained in microfabricated millimeter-scale vapor cells. In the first part of the thesis, we improved different features of current microfabricated optical magnetometers. Specifically, we improved the bandwidth of these devices, without degrading their magnetic field sensitivity, by broadening their magnetic resonance through spin-exchange collisions between alkali atoms. We also implemented all-optical excitation techniques to avoid problems, such as the magnetic perturbation of the environment, induced by the radio-frequency fields used in some of these sensors. In the second part of the thesis we demonstrated a microfluidic chip for the optical production and detection of hyperpolarized Xe gas through spin-exchange collisions with optically pumped Rb atoms. These devices are critical for the widespread use of spin polarized atomic magnetometers in applications requiring simple, compact, low-cost, and portable instrumentation.
For the experimental implementation of an optically pumped atomic magnetometer, the magnetic resonance signal with a narrow linewidth and a high signal-to-noise ratio (SNR) is required for achieving a high sensitivity. Using 795-nm laser as both the pumping and the probe laser, we compare the magnetic resonance signals from different rubidium atomic vapor cells and investigate the variations of magnetic resonance signals with temperature. Optimized magnetic resonance signal is achieved with a paraffin-coated rubidium atomic vapor cell. Then the 780-nm laser at rubidium D2 line is introduced as a repumping laser, and we explore the changes of linewidth and SNR of the magnetic resonance signal under different power of the pumping laser and the repumping laser. Owing to the 780-nm repumping laser beam, the signal amplitude of rubidium-85 magnetic resonance signal is improved remarkably because more rubidium-85 atoms are spin- polarized by the 795-nm pumping laser beam. At the same time, the linewidth of rubidium-85 magnetic resonance signal is roughly not broadened anymore. We realize a closed-loop optically pumped rubidium-85 atomic magnetometer with a bandwidth of ~1.2 kHz, and the sensitivity is calibrated to be ~245.5 pT/Hz1/2 only with the 795-nm pumping laser beam. Owing to the employment of the 780-nm repumping laser beam, the sensitivity is improved to be ~26.4 pT/Hz1/2 which is improved roughly by one order of magnitude. We also calibrate the measurement accuracy and deviation of a commercial fluxgate magnetometer by using the enhanced rubidium magnetic resonance signal.