Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE/LEOS Summer Topical Meetings

In-situ calibration of fiber-optics entangled photon distribution system

Daniel E. Jones, Brian T. Kirby, Michael Brodsky

Published Jul 1, 2017• 5 citations
Publisher

Abstract

A source of entangled photons is connected via optical fibers to two single photon detectors. By simultaneously measuring pump power dependencies of the detection probabilities at each detector, as well as the probability of coincidence counts, we reliably extract all relevant system parameters.
DOI
10.1109/phosst.2017.8012681

Related papers

Joint Characterization of Two Single Photon Detectors with a Fiber-based Source of Entangled Photon Pairs

Daniel E. Jones, Brian T. Kirby, Michael Brodsky

By simultaneously measuring individual and coincidence counts of two single photon detectors connected to an entangled photon pair source, we extract the detector efficiencies, the average number of generated pairs, and the Raman noise floor.

Frontiers in Optics•Jan 1, 2017•6 citations

Calibration of a single-photon counting detectors without the need of input photon flux calibration (Conference Presentation)

Thomas Gerrits

Calibration of fiber-coupled single-photon detectors usually requires knowledge of the input photon flux inside the fiber and/or knowledge of the linearity of a reference power meter. Many approaches have been presented in the past to accurately measure the photon detection probability of a single photon detector [1-6]. Under certain assumptions, one can utilize waveguide-coupled single photon detectors and a series of photon-counting measurements and a single-photon source to calibrate the detection efficiency of a single photon detector without the need of a reference power meter and the knowledge of the incoming photon flux. Here, this method is presented. Furthermore, if a reference detector is used, the detection efficiency of all evanescently coupled waveguide detectors can be measured, and the measurement outcome does not depend on splicing or fiber connection losses within in the setup, i.e., the measurement is setup-independent. In addition, the method, when using a reference detector, can be utilized to measure and distinguish between the absorption of a waveguide-coupled single photon detector and its internal detection efficiency. [1] A. J. Miller et al, Opt. Express 19, 9102–9110 (2011) [2] I. Muller et al., Metrologia 51, S329 (2014). [3] A. L. Migdall, Instrumentation and Measurement, IEEE Transactions on 50, 478–481 (2001). [4] S. V. Polyakov, A. L. Migdall, Optics Express 15, 1390–1407 (2007). [5] A. Avella et al., Optics Express 19, 23249–23257 (2011). [6] T. Lunghi et al., Opt. Express 22, 18078-18092 (2014)

•Jun 9, 2017•0 citations

Characterizing the noise output by a fiber-based entangled photon source

Atiyya A. Davis, Brian T. Kirby, Thomas A. Searles +1 more

By simultaneously measuring individual and coincidence counts of two single photon detectors connected to a fiber-based entangled photon source and fitting the results with a theoretical model of the photon generation rates, we determine the average number of polarization-entangled photon pairs generated by four-wave mixing and the average number of noise photons generated by Raman scattering and self-phase modulation of the pump as a function of power. In contrast to previous efforts to characterize fiber-based entangled photon sources, this method does not require additional coherence-based measurements to distinguish SPM photons from FWM and Raman-scattered photons.

Quantum Communications and Quantum Imaging•Oct 3, 2023•0 citations

Absolute calibration of photon-counting detection efficiency using photon pairs generated in optical fibers

Xiaoying Li, Xiaoxin Ma, Lei Yang +4 more

Using the correlated signal and idler photon pairs in 1550 nm band generated in 300 m dispersion shifted fiber by a pulsed pump, we measure the quantum efficiency of a InGaAs/InP avalanche photodiode based single photon detector. The measurement can be done by using photon pairs with various kinds of bandwidth.

AIP conference proceedings•Jan 1, 2011•0 citations

Proposal for calibration of a single-photon counting detector without the need of input photon flux calibration

Thomas Gerrits

A method for calibration of single-photon detectors without the need of input photon flux calibration is presented. The method relies on the use of waveguide-coupled single photon detectors and a series of photon-counting measurements using a single-photon source. It is shown that the method can yield relative uncertainties of less than 1% including counting statistics and fiber splice loss uncertainties with a total measurement time of about 1 h under the assumptions that the fractional losses of the waveguide-coupled detectors are known or zero and the loss along the waveguide is constant. It is also shown that the fractional losses of the waveguide-coupled detectors can be determined if they are equal. However, in this case an input photon flux calibration is required.

Optics Express•Apr 4, 2016•0 citations

All-fiber photon-pair source for practical quantum communications

Prem Kumar, Marco Fiorentino B, Paul L. Voss +1 more

Q uantum entanglement refers to the nonclassical dependency of physically separated quantum systems. It is an essential resource that must be freely available for implementing many of the novel functions of quantum information processing, such as database searching, clock synchronization, teleportation, computing and cryptography.1 The efficient generation and transmission of quantum entanglement is therefore of prime importance. With the ubiquitous standard optical fiber serving as the transmission medium and the widespread availability of efficient active and passive fiber devices, technological synergy between the generation and propagation components of the overall quantum network can be achieved by deploying sources of entanglement that rely on the nonlinearity of the fiber itself. Such fiber-based sources of quantum entanglement would also have the advantage of modal purity over their crystal counterparts,2,3 which is very important for realizing complex networks that involve many quantum operations. In our quest to develop fiber-based devices for quantum information processing, we have recently demonstrated an allfiber source of quantum-correlated photon pairs.4 The operating physical mechanism in this source is nondegenerate fourphoton mixing, wherein two pump photons scatter through the Kerr nonlinearity of the fiber to create simultaneous signal and idler photons. Our experiment is conducted near the zero-dispersion wavelength of standard dispersion-shifted fiber, where such scattering is enhanced owing to phase matching of the photon wave functions. It must be pointed out here that in a conventional wavelength-divisionmultiplexed classical optical communication line, one strives to suppress the fourphoton or four-wave mixing process, which otherwise causes cross talk between the wavelength channels and sets limits on the total data capacity of the communication line. In our experiment, the four-photon mixing takes place in a nonlinear-fiber Sagnac interferometer (NFSI), which we previously used to generate quantum-correlated twin beams in the fiber.5 The pump is a mode-locked train of ~3-ps-long pulses. The pulsed operation serves two important purposes: the NFSI amplifier can be operated at low average powers and the production of the signal/ idler fluorescence photons is confined to well-defined temporal windows, allowing use of a gated detection scheme to increase the signal-to-noise ratio. To measure the nonclassical (i.e., quantum) correlations between the signal and the idler photons, one must effectively suppress the pump photons from reaching the detectors. Since a typical pump pulse contains ~108 photons and we are interested in detecting ~0.01 signal (idler) photons/pulse, a pump-to-signal (idler) rejection ratio in excess of 100 dB is required. We achieved this specification by sending the fluorescence photons through a free-space double-grating spectral filter that separates the signal and idler photons from each other and from the pump photons not rejected by the NFSI. To demonstrate the quantum nature of the four-photon scattering at the single photon level, we assembled a photonFigure 1.C oincidence rates as a function of the single-photon rates in two different cases: signalidler fluorescence produced by a pump pulse (diamonds) and signal-idler fluorescence produced by two consecutive pump pulses (triangles). T he line represents the calculated accidental counts. T he inset shows a plot of the detected idler photons as a function of the injected pump photons (hollow circles). A second-order polynomial is shown to fit the experimental data. T he contributions of the dark counts, linear scattering and quadratic scattering are plotted separately as well. counting apparatus for detecting the signal and idler photons in coincidence. This apparatus is based on commercial InGaAs avalanche photodiodes operating in the gated Geiger mode.4 In the inset in Fig. 1, we show the number of scattered photons, NS, versus the number of pump photons, NP, injected into the NFSI. We fit the experimental data with a second-order polynomial fit, including the number of dark counts during the gate interval, ND. The fit clearly shows that the quadratic scattering ( ∝NP) in the fiber can dominate over the residual linear scattering ( ∝NP) of the pump, owing to imperfect filtering. The main body of Fig. 1 shows the coincidence-counting results. The diamonds represent the rate of coincidence counts versus the rate of the signal (idler) photons generated during the same pump pulse. The triangles represent the measured coincidence rate versus the signalphoton count rate when the signal is delayed with respect to the idler by one pulse period. For two independent photon sources, each with a count rate RS <<1, the accidental coincidence rate RC is given by RC = RS 2, regardless of the photon statistics of the sources. This quadratic relation is plotted as the solid line in Fig. 1, which fits the delayed-coincidence data (triangles) very well. These measurements show that while the fluorescence photons produced by the adjacent pump pulses are independent, those coming from the same pump pulse show a strong correlation, which is a signature of their non-classical behavior. This work was supported by the Department of Defense Multidisciplinary University Research Initiative program administered by the Army Research Office under Grants DAAD19-00-1-0177 and DAAD19-00-1-0469, and by the U.S. Office of Naval Research under Grant N00014-91-J-1268.

•Jan 1, 2002•5 citations
Calibration of fiber-coupled single-photon detectors usually requires knowledge of the input photon flux inside the fiber and/or knowledge of the linearity of a reference power meter. Many approaches have been presented in the past to accurately measure the photon detection probability of a single photon detector [1-6]. Under certain assumptions, one can utilize waveguide-coupled single photon detectors and a series of photon-counting measurements and a single-photon source to calibrate the detection efficiency of a single photon detector without the need of a reference power meter and the knowledge of the incoming photon flux. Here, this method is presented. Furthermore, if a reference detector is used, the detection efficiency of all evanescently coupled waveguide detectors can be measured, and the measurement outcome does not depend on splicing or fiber connection losses within in the setup, i.e., the measurement is setup-independent. In addition, the method, when using a reference detector, can be utilized to measure and distinguish between the absorption of a waveguide-coupled single photon detector and its internal detection efficiency. [1] A. J. Miller et al, Opt. Express 19, 9102–9110 (2011) [2] I. Muller et al., Metrologia 51, S329 (2014). [3] A. L. Migdall, Instrumentation and Measurement, IEEE Transactions on 50, 478–481 (2001). [4] S. V. Polyakov, A. L. Migdall, Optics Express 15, 1390–1407 (2007). [5] A. Avella et al., Optics Express 19, 23249–23257 (2011). [6] T. Lunghi et al., Opt. Express 22, 18078-18092 (2014)
By simultaneously measuring individual and coincidence counts of two single photon detectors connected to a fiber-based entangled photon source and fitting the results with a theoretical model of the photon generation rates, we determine the average number of polarization-entangled photon pairs generated by four-wave mixing and the average number of noise photons generated by Raman scattering and self-phase modulation of the pump as a function of power. In contrast to previous efforts to characterize fiber-based entangled photon sources, this method does not require additional coherence-based measurements to distinguish SPM photons from FWM and Raman-scattered photons.
A method for calibration of single-photon detectors without the need of input photon flux calibration is presented. The method relies on the use of waveguide-coupled single photon detectors and a series of photon-counting measurements using a single-photon source. It is shown that the method can yield relative uncertainties of less than 1% including counting statistics and fiber splice loss uncertainties with a total measurement time of about 1 h under the assumptions that the fractional losses of the waveguide-coupled detectors are known or zero and the loss along the waveguide is constant. It is also shown that the fractional losses of the waveguide-coupled detectors can be determined if they are equal. However, in this case an input photon flux calibration is required.
Q uantum entanglement refers to the nonclassical dependency of physically separated quantum systems. It is an essential resource that must be freely available for implementing many of the novel functions of quantum information processing, such as database searching, clock synchronization, teleportation, computing and cryptography.1 The efficient generation and transmission of quantum entanglement is therefore of prime importance. With the ubiquitous standard optical fiber serving as the transmission medium and the widespread availability of efficient active and passive fiber devices, technological synergy between the generation and propagation components of the overall quantum network can be achieved by deploying sources of entanglement that rely on the nonlinearity of the fiber itself. Such fiber-based sources of quantum entanglement would also have the advantage of modal purity over their crystal counterparts,2,3 which is very important for realizing complex networks that involve many quantum operations. In our quest to develop fiber-based devices for quantum information processing, we have recently demonstrated an allfiber source of quantum-correlated photon pairs.4 The operating physical mechanism in this source is nondegenerate fourphoton mixing, wherein two pump photons scatter through the Kerr nonlinearity of the fiber to create simultaneous signal and idler photons. Our experiment is conducted near the zero-dispersion wavelength of standard dispersion-shifted fiber, where such scattering is enhanced owing to phase matching of the photon wave functions. It must be pointed out here that in a conventional wavelength-divisionmultiplexed classical optical communication line, one strives to suppress the fourphoton or four-wave mixing process, which otherwise causes cross talk between the wavelength channels and sets limits on the total data capacity of the communication line. In our experiment, the four-photon mixing takes place in a nonlinear-fiber Sagnac interferometer (NFSI), which we previously used to generate quantum-correlated twin beams in the fiber.5 The pump is a mode-locked train of ~3-ps-long pulses. The pulsed operation serves two important purposes: the NFSI amplifier can be operated at low average powers and the production of the signal/ idler fluorescence photons is confined to well-defined temporal windows, allowing use of a gated detection scheme to increase the signal-to-noise ratio. To measure the nonclassical (i.e., quantum) correlations between the signal and the idler photons, one must effectively suppress the pump photons from reaching the detectors. Since a typical pump pulse contains ~108 photons and we are interested in detecting ~0.01 signal (idler) photons/pulse, a pump-to-signal (idler) rejection ratio in excess of 100 dB is required. We achieved this specification by sending the fluorescence photons through a free-space double-grating spectral filter that separates the signal and idler photons from each other and from the pump photons not rejected by the NFSI. To demonstrate the quantum nature of the four-photon scattering at the single photon level, we assembled a photonFigure 1.C oincidence rates as a function of the single-photon rates in two different cases: signalidler fluorescence produced by a pump pulse (diamonds) and signal-idler fluorescence produced by two consecutive pump pulses (triangles). T he line represents the calculated accidental counts. T he inset shows a plot of the detected idler photons as a function of the injected pump photons (hollow circles). A second-order polynomial is shown to fit the experimental data. T he contributions of the dark counts, linear scattering and quadratic scattering are plotted separately as well. counting apparatus for detecting the signal and idler photons in coincidence. This apparatus is based on commercial InGaAs avalanche photodiodes operating in the gated Geiger mode.4 In the inset in Fig. 1, we show the number of scattered photons, NS, versus the number of pump photons, NP, injected into the NFSI. We fit the experimental data with a second-order polynomial fit, including the number of dark counts during the gate interval, ND. The fit clearly shows that the quadratic scattering ( ∝NP) in the fiber can dominate over the residual linear scattering ( ∝NP) of the pump, owing to imperfect filtering. The main body of Fig. 1 shows the coincidence-counting results. The diamonds represent the rate of coincidence counts versus the rate of the signal (idler) photons generated during the same pump pulse. The triangles represent the measured coincidence rate versus the signalphoton count rate when the signal is delayed with respect to the idler by one pulse period. For two independent photon sources, each with a count rate RS <<1, the accidental coincidence rate RC is given by RC = RS 2, regardless of the photon statistics of the sources. This quadratic relation is plotted as the solid line in Fig. 1, which fits the delayed-coincidence data (triangles) very well. These measurements show that while the fluorescence photons produced by the adjacent pump pulses are independent, those coming from the same pump pulse show a strong correlation, which is a signature of their non-classical behavior. This work was supported by the Department of Defense Multidisciplinary University Research Initiative program administered by the Army Research Office under Grants DAAD19-00-1-0177 and DAAD19-00-1-0469, and by the U.S. Office of Naval Research under Grant N00014-91-J-1268.