In-situ calibration of fiber-optics entangled photon distribution system

Daniel E. Jones, Brian T. Kirby, Michael Brodsky

Published Jul 1, 2017• 6 citations
Publisher

Abstract

A source of entangled photons is connected via optical fibers to two single photon detectors. By simultaneously measuring pump power dependencies of the detection probabilities at each detector, as well as the probability of coincidence counts, we reliably extract all relevant system parameters.
DOI
10.1109/phosst.2017.8012681

Related papers

Joint Characterization of Two Single Photon Detectors with a Fiber-based Source of Entangled Photon Pairs

Daniel E. Jones, Brian T. Kirby, Michael Brodsky

By simultaneously measuring individual and coincidence counts of two single photon detectors connected to an entangled photon pair source, we extract the detector efficiencies, the average number of generated pairs, and the Raman noise floor.

Frontiers in Optics•Jan 1, 2017•7 citations

Calibration of a single-photon counting detectors without the need of input photon flux calibration (Conference Presentation)

Thomas Gerrits

Calibration of fiber-coupled single-photon detectors usually requires knowledge of the input photon flux inside the fiber and/or knowledge of the linearity of a reference power meter. Many approaches have been presented in the past to accurately measure the photon detection probability of a single photon detector [1-6]. Under certain assumptions, one can utilize waveguide-coupled single photon detectors and a series of photon-counting measurements and a single-photon source to calibrate the detection efficiency of a single photon detector without the need of a reference power meter and the knowledge of the incoming photon flux. Here, this method is presented. Furthermore, if a reference detector is used, the detection efficiency of all evanescently coupled waveguide detectors can be measured, and the measurement outcome does not depend on splicing or fiber connection losses within in the setup, i.e., the measurement is setup-independent. In addition, the method, when using a reference detector, can be utilized to measure and distinguish between the absorption of a waveguide-coupled single photon detector and its internal detection efficiency. [1] A. J. Miller et al, Opt. Express 19, 9102–9110 (2011) [2] I. Muller et al., Metrologia 51, S329 (2014). [3] A. L. Migdall, Instrumentation and Measurement, IEEE Transactions on 50, 478–481 (2001). [4] S. V. Polyakov, A. L. Migdall, Optics Express 15, 1390–1407 (2007). [5] A. Avella et al., Optics Express 19, 23249–23257 (2011). [6] T. Lunghi et al., Opt. Express 22, 18078-18092 (2014)

•Jun 9, 2017•0 citations

Characterizing the noise output by a fiber-based entangled photon source

Atiyya A. Davis, Brian T. Kirby, Thomas A. Searles +1 more

By simultaneously measuring individual and coincidence counts of two single photon detectors connected to a fiber-based entangled photon source and fitting the results with a theoretical model of the photon generation rates, we determine the average number of polarization-entangled photon pairs generated by four-wave mixing and the average number of noise photons generated by Raman scattering and self-phase modulation of the pump as a function of power. In contrast to previous efforts to characterize fiber-based entangled photon sources, this method does not require additional coherence-based measurements to distinguish SPM photons from FWM and Raman-scattered photons.

Quantum Communications and Quantum Imaging•Oct 3, 2023•0 citations

Absolute calibration of photon-counting detection efficiency using photon pairs generated in optical fibers

Xiaoying Li, Xiaoxin Ma, Lei Yang +4 more

Using the correlated signal and idler photon pairs in 1550 nm band generated in 300 m dispersion shifted fiber by a pulsed pump, we measure the quantum efficiency of a InGaAs/InP avalanche photodiode based single photon detector. The measurement can be done by using photon pairs with various kinds of bandwidth.

AIP conference proceedings•Jan 1, 2011•0 citations

Proposal for calibration of a single-photon counting detector without the need of input photon flux calibration

Thomas Gerrits

A method for calibration of single-photon detectors without the need of input photon flux calibration is presented. The method relies on the use of waveguide-coupled single photon detectors and a series of photon-counting measurements using a single-photon source. It is shown that the method can yield relative uncertainties of less than 1% including counting statistics and fiber splice loss uncertainties with a total measurement time of about 1 h under the assumptions that the fractional losses of the waveguide-coupled detectors are known or zero and the loss along the waveguide is constant. It is also shown that the fractional losses of the waveguide-coupled detectors can be determined if they are equal. However, in this case an input photon flux calibration is required.

Journal of Optics•Apr 4, 2016•4 citations

Proposal for calibration of a single-photon counting detector without the need of input photon flux calibration

Thomas Gerrits

A method for calibration of single-photon detectors without the need of input photon flux calibration is presented. The method relies on the use of waveguide-coupled single photon detectors and a series of photon-counting measurements using a single-photon source. It is shown that the method can yield relative uncertainties of less than 1% including counting statistics and fiber splice loss uncertainties with a total measurement time of about 1 h under the assumptions that the fractional losses of the waveguide-coupled detectors are known or zero and the loss along the waveguide is constant. It is also shown that the fractional losses of the waveguide-coupled detectors can be determined if they are equal. However, in this case an input photon flux calibration is required.

Optics Express•Apr 4, 2016•0 citations
Calibration of fiber-coupled single-photon detectors usually requires knowledge of the input photon flux inside the fiber and/or knowledge of the linearity of a reference power meter. Many approaches have been presented in the past to accurately measure the photon detection probability of a single photon detector [1-6]. Under certain assumptions, one can utilize waveguide-coupled single photon detectors and a series of photon-counting measurements and a single-photon source to calibrate the detection efficiency of a single photon detector without the need of a reference power meter and the knowledge of the incoming photon flux. Here, this method is presented. Furthermore, if a reference detector is used, the detection efficiency of all evanescently coupled waveguide detectors can be measured, and the measurement outcome does not depend on splicing or fiber connection losses within in the setup, i.e., the measurement is setup-independent. In addition, the method, when using a reference detector, can be utilized to measure and distinguish between the absorption of a waveguide-coupled single photon detector and its internal detection efficiency. [1] A. J. Miller et al, Opt. Express 19, 9102–9110 (2011) [2] I. Muller et al., Metrologia 51, S329 (2014). [3] A. L. Migdall, Instrumentation and Measurement, IEEE Transactions on 50, 478–481 (2001). [4] S. V. Polyakov, A. L. Migdall, Optics Express 15, 1390–1407 (2007). [5] A. Avella et al., Optics Express 19, 23249–23257 (2011). [6] T. Lunghi et al., Opt. Express 22, 18078-18092 (2014)
By simultaneously measuring individual and coincidence counts of two single photon detectors connected to a fiber-based entangled photon source and fitting the results with a theoretical model of the photon generation rates, we determine the average number of polarization-entangled photon pairs generated by four-wave mixing and the average number of noise photons generated by Raman scattering and self-phase modulation of the pump as a function of power. In contrast to previous efforts to characterize fiber-based entangled photon sources, this method does not require additional coherence-based measurements to distinguish SPM photons from FWM and Raman-scattered photons.
A method for calibration of single-photon detectors without the need of input photon flux calibration is presented. The method relies on the use of waveguide-coupled single photon detectors and a series of photon-counting measurements using a single-photon source. It is shown that the method can yield relative uncertainties of less than 1% including counting statistics and fiber splice loss uncertainties with a total measurement time of about 1 h under the assumptions that the fractional losses of the waveguide-coupled detectors are known or zero and the loss along the waveguide is constant. It is also shown that the fractional losses of the waveguide-coupled detectors can be determined if they are equal. However, in this case an input photon flux calibration is required.
A method for calibration of single-photon detectors without the need of input photon flux calibration is presented. The method relies on the use of waveguide-coupled single photon detectors and a series of photon-counting measurements using a single-photon source. It is shown that the method can yield relative uncertainties of less than 1% including counting statistics and fiber splice loss uncertainties with a total measurement time of about 1 h under the assumptions that the fractional losses of the waveguide-coupled detectors are known or zero and the loss along the waveguide is constant. It is also shown that the fractional losses of the waveguide-coupled detectors can be determined if they are equal. However, in this case an input photon flux calibration is required.