Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Minimizing Time Dilation in Penning Trap Ion Clocks, | NIST

Joseph N. Tan, J. J. Bollinger, David J. Wineland

Published Jan 1, 1995• 0 citations
OpenAlex

Related papers

Laser-cooled ion plasmas in Penning Traps | NIST

J. J. Bollinger, Jason M. Kriesel, T. B. Mitchell +4 more

Journal of Physics B Atomic Molecular and Optical Physics•Jan 23, 2003•0 citations

Reducing time-dilation uncertainty in the NIST Al+ quantum-logic clock

Samuel M. Brewer, Jwo-Sy Chen, Aaron M. Hankin +5 more

Bulletin of the American Physical Society•Jun 7, 2017•0 citations

High-Fidelity Quantum Control Using 9Be+ Ion Crystals in a Penning Trap | NIST

Michael J. Biercuk, Hermann Uys, Aaron P. VanDevender +3 more

Quantum Information and Computation•Aug 19, 2009•0 citations

Minimizing time dilation shift in Penning trap atomic clocks

J.N. Tan, J.J. Bollinger, D.J. Wineland

The time dilation shift is expected to give the largest systematic uncertainty in an ion clock. We show that, in a Penning trap, it can be minimized if the ions are prepared in a special spheroid. The results apply directly for one ion species and approximately for sympathetically cooled systems.>

Conference on Precision Electromagnetic Measurements•Dec 17, 2002•1 citation

Atomic Physics in Ion Traps | NIST

Christopher R. Monroe, J. J. Bollinger

Physics World•Mar 1, 1997•1 citation

Minimizing the time-dilation shift in Penning trap atomic clocks

Jun Tan, J. J. Bollinger, David J. Wineland

If environmental perturbations are made negligible, the time-dilation shift is expected to give one of the largest systematic uncertainties in a stored ion clock. In general, this shift increases with the number of trapped ions. Fluctuations in the time dilation shift therefore could limit the frequency stability of an ion clock. We show that in a Penning trap, relativistic time dilation can be minimized if the laser-cooled ions are prepared in a special spheroidal state. In addition, a modest stabilization of the spheroid near the minimum-shift configuration fan significantly reduce fluctuations in the time dilation. The results obtained for a single-species ion clock also provide a good approximation for a sympathetically cooled system.>

IEEE Transactions on Instrumentation and Measurement•Apr 1, 1995•19 citations
If environmental perturbations are made negligible, the time-dilation shift is expected to give one of the largest systematic uncertainties in a stored ion clock. In general, this shift increases with the number of trapped ions. Fluctuations in the time dilation shift therefore could limit the frequency stability of an ion clock. We show that in a Penning trap, relativistic time dilation can be minimized if the laser-cooled ions are prepared in a special spheroidal state. In addition, a modest stabilization of the spheroid near the minimum-shift configuration fan significantly reduce fluctuations in the time dilation. The results obtained for a single-species ion clock also provide a good approximation for a sympathetically cooled system.>