Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEICE Technical Report; IEICE Tech. Rep.

On the density ratio of alkali metal atoms in an optically pumped K-Rb hybrid atomic magnetometer

Daichi Sato, Keigo Kamada, Yosuke Ito, Tetsuo Kobayashi

Published Dec 6, 2014• 0 citations
OpenAlex

Related papers

On an optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms

Hiroyuki Ohnishi, Yosuke Ito, Tetsuo Kobayashi

電気学会研究会資料. MAG, マグネティックス研究会•Sep 24, 2012•0 citations

Density-ratio dependence of spin polarization and spatial homogeneity in hybrid Rb–Cs vapor cells

Ge Jin, Tao shi, Yuxin Chen +2 more

Abstract Hybrid spin-exchange optical pumping (hybrid SEOP) using multiple alkali-metal species is commonly employed to improve the spatial homogeneity of alkali spin polarization in atomic magnetometers and comagnetometers. We investigate the dependence of spin polarization and its spatial homogeneity on the alkali density ratio D r = [ Rb ] / [ Cs ] in Rb–Cs hybrid vapor cells. A series of cells with controlled D r were fabricated and characterized using absolute electron paramagnetic resonance polarimetry at multiple positions along the cell axis. The results show that the density ratio strongly influences both the magnitude and spatial uniformity of alkali polarization through the competition among optical pumping, spin exchange, and spin-destruction processes. An optimal density ratio is observed near D r ≈ 6.59 ± 0.47 , where the polarization reaches its maximum while maintaining high spatial homogeneity (end-to-end ratio ∼89% and RMS homogeneity > 95 % ). Under typical operating conditions, the optimal density ratio lies in the range D r ≈ 4 –10. These results clarify the role of the alkali density ratio in Rb–Cs hybrid SEOP and provide practical guidance for optimizing hybrid vapor cells used in precision atomic magnetometers and comagnetometers.

Journal of Physics D Applied Physics•Apr 21, 2026•1 citation

Optimization of the alkali-metal density ratio in a hybrid optical pumping atomic magnetometer

Yang Li, Xue-Jing Liu, Hongwei Cai +2 more

Abstract The alkali-metal density ratio is one of the primary design parameters in hybrid optical pumping magnetometers. Here, experiments were conducted with a hybrid optically-pumped atomic magnetometer using a cell containing potassium and rubidium. Potassium atoms are pumped by a laser and become polarized. Rubidium atoms are polarized via collisions with potassium atoms and can be probed. The light shift was eliminated by adjusting the density ratio of potassium to rubidium atoms and by optimizing the pump laser parameters. The effect of fluctuations in the laser power and frequency were minimized as a result. The optimal density ratio and magnetic field sensitivity were 1:277 and 0.68 fT Hz −1/2 , respectively.

Measurement Science and Technology•Nov 9, 2018•19 citations

Developments in alkali -metal atomic magnetometry

Scott J. Seltzer

•Jan 1, 2008•307 citations

A compact Faraday rotation monitor for density and polarization of optically pumped alkali atoms

J. Stenger, M. Beckmann, W. Nagengast +1 more

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Jan 1, 1997•5 citations

Research on the influence of alkali polarization on an all-optical atomic spin magnetometer based on hybrid pumping potassium and rubidium

Hong Zhang, Sheng Zou, Xiyuan Chen +1 more

An all-optical atomic spin magnetometer using a hybrid cell of K and Rb atoms is demonstrated in this paper. Via deriving and solving the Bloch equations, we established the models for the polarization rate of Rb and the magnetometer’s output signal, respectively. In order to achieve the maximum sensitivity, we carried out research on the influence of the pump power on the polarization rate and magnetometer’s output signal. The magnetometer’s sensitivity was found to be proportional to the polarization rate of Rb, which was confined by the pump power. In a certain context, theoretical predictions indicated that the larger the pump power was, the higher magnetometer’s sensitivity that could be realized. However, the theoretical estimate deviated from the experimental results. An analysis of the errors between the actual value and the theoretical value showed that the different molar ratio between the two species of alkali-metal atoms was the primary reason causing the deviation. By comparing the experimental measurement result with simulation result, we found the difference in the molar ratio to be approximate 4 times. After various parameters had been optimized, a sensitivity of 18 fT/Hz 1/2 was achieved by analyzing the signal-to-noise ratio.

Journal of the Korean Physical Society•Apr 1, 2015•9 citations
Abstract Hybrid spin-exchange optical pumping (hybrid SEOP) using multiple alkali-metal species is commonly employed to improve the spatial homogeneity of alkali spin polarization in atomic magnetometers and comagnetometers. We investigate the dependence of spin polarization and its spatial homogeneity on the alkali density ratio D r = [ Rb ] / [ Cs ] in Rb–Cs hybrid vapor cells. A series of cells with controlled D r were fabricated and characterized using absolute electron paramagnetic resonance polarimetry at multiple positions along the cell axis. The results show that the density ratio strongly influences both the magnitude and spatial uniformity of alkali polarization through the competition among optical pumping, spin exchange, and spin-destruction processes. An optimal density ratio is observed near D r ≈ 6.59 ± 0.47 , where the polarization reaches its maximum while maintaining high spatial homogeneity (end-to-end ratio ∼89% and RMS homogeneity > 95 % ). Under typical operating conditions, the optimal density ratio lies in the range D r ≈ 4 –10. These results clarify the role of the alkali density ratio in Rb–Cs hybrid SEOP and provide practical guidance for optimizing hybrid vapor cells used in precision atomic magnetometers and comagnetometers.
Abstract The alkali-metal density ratio is one of the primary design parameters in hybrid optical pumping magnetometers. Here, experiments were conducted with a hybrid optically-pumped atomic magnetometer using a cell containing potassium and rubidium. Potassium atoms are pumped by a laser and become polarized. Rubidium atoms are polarized via collisions with potassium atoms and can be probed. The light shift was eliminated by adjusting the density ratio of potassium to rubidium atoms and by optimizing the pump laser parameters. The effect of fluctuations in the laser power and frequency were minimized as a result. The optimal density ratio and magnetic field sensitivity were 1:277 and 0.68 fT Hz −1/2 , respectively.
An all-optical atomic spin magnetometer using a hybrid cell of K and Rb atoms is demonstrated in this paper. Via deriving and solving the Bloch equations, we established the models for the polarization rate of Rb and the magnetometer’s output signal, respectively. In order to achieve the maximum sensitivity, we carried out research on the influence of the pump power on the polarization rate and magnetometer’s output signal. The magnetometer’s sensitivity was found to be proportional to the polarization rate of Rb, which was confined by the pump power. In a certain context, theoretical predictions indicated that the larger the pump power was, the higher magnetometer’s sensitivity that could be realized. However, the theoretical estimate deviated from the experimental results. An analysis of the errors between the actual value and the theoretical value showed that the different molar ratio between the two species of alkali-metal atoms was the primary reason causing the deviation. By comparing the experimental measurement result with simulation result, we found the difference in the molar ratio to be approximate 4 times. After various parameters had been optimized, a sensitivity of 18 fT/Hz 1/2 was achieved by analyzing the signal-to-noise ratio.