Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Nanomechanical motion measured with an imprecision below the standard quantum limit

Tobias Donner

Published May 28, 2010• 0 citations
OpenAlex

Related papers

Nanomechanical motion measured with an imprecision below that at the standard quantum limit

John D. Teufel, Tobias Donner, Manuel A. Castellanos-Beltran +2 more

arXiv:0906.1212•Nature Nanotechnology•Nov 1, 2009•499 citations

Back-action-evading measurements of nanomechanical motion

Jared Hertzberg, Tristan O. Rocheleau, Tchefor Ndukum +3 more

arXiv:0906.0967•Nature Physics•Dec 6, 2009•240 citations

Back action evading quantum limited measurements of a nanomechanical resonator

Tchefor Ndukum, Tristan O. Rocheleau, Jared Hertzberg +1 more

Bulletin of the American Physical Society•Mar 20, 2009•0 citations

Measuring nanomechanical motion with an imprecision below that at the standard quantum limit

G. Anetsberger, P. Verlot, E. Gavartin +6 more

Using optical readout, we demonstrate for the first time sub-SQL imprecision for nanomechanical motion at room temperature.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2011•5 citations

Measuring nanomechanical motion with an imprecision below the standard quantum limit

G. Anetsberger, E. Gavartin, O. Arcizet +5 more

We report a room-temperature measurement of nanomechanical motion with an imprecision below the standard quantum limit (SQL), using cavity-enhanced optical near fields. Fundamental thermodynamical cavity frequency fluctuation limits the total imprecision to $3 \mathrm{dB}$ below the SQL at room temperature [corresponding to $(530 \mathrm{am}/\sqrt{\mathrm{Hz}}){}^{2}$ in absolute units] and is expected to reduce to negligible values at moderate cryogenic temperatures. Coupling strengths exceeding those required to reach the SQL by more than two orders of magnitude are achieved, allowing a shot-noise limited imprecision more than $10 \mathrm{dB}$ below the SQL. The transducer, thus, in principle, allows access to the quantum backaction dominated regime, a prerequisite for exploring quantum backaction, measurement-induced squeezing, and obtaining sub-SQL sensitivity using backaction evading techniques.

arXiv:1003.3752•Physical Review A•Dec 29, 2010•154 citations

Quantum-state Measurement in a Nanomechanical System

Seung‐Bo Shim

Physics and High Technology•Jun 30, 2016•0 citations
We report a room-temperature measurement of nanomechanical motion with an imprecision below the standard quantum limit (SQL), using cavity-enhanced optical near fields. Fundamental thermodynamical cavity frequency fluctuation limits the total imprecision to 3dB3 \mathrm{dB}3dB below the SQL at room temperature [corresponding to (530am/Hz)2(530 \mathrm{am}/\sqrt{\mathrm{Hz}}){}^{2}(530am/Hz​)2 in absolute units] and is expected to reduce to negligible values at moderate cryogenic temperatures. Coupling strengths exceeding those required to reach the SQL by more than two orders of magnitude are achieved, allowing a shot-noise limited imprecision more than 10dB10 \mathrm{dB}10dB below the SQL. The transducer, thus, in principle, allows access to the quantum backaction dominated regime, a prerequisite for exploring quantum backaction, measurement-induced squeezing, and obtaining sub-SQL sensitivity using backaction evading techniques.