Experimental study of a hybrid SFQ digital SQUID magnetometer

Torsten Reich, Pascal Febvre, Thomas Ortlepp, Friedrich Uhlmann, J. Kunert, Ronny Stolz, H.‐G. Meyer

Published Jul 1, 2008• 3 citations
OpenAlex

Related papers

Design and Applications of Digital SQUID Magnetometer with Sub-Flux Quantum Feedback

Myoren Hiroaki, Kosuke Okabe, Kamiya Ryotaro +2 more

IEICE Technical Report; IEICE Tech. Rep.•Apr 14, 2017•0 citations

Performance of Digital SQUID magnetometer using Multi-Flux Quantum Feedback

Itta Oshima, Uchida Sohei, Masato Naruse +2 more

IEICE Technical Report; IEICE Tech. Rep.•Aug 26, 2020•0 citations

Design of Digital SQUID using sub-SFQ Feedback with High Sampling Rate

Kosuke Okabe, Masato Naruse, Tohru Taino +1 more

IEICE Technical Report; IEICE Tech. Rep.•Aug 2, 2017•0 citations

Design of sub-Flux Quantum Feedback Digital SQUID Magnetometer with First-order Sinc Filter

Ryo Matsunawa, Kosuke Okabe, Masato Naruse +2 more

IEICE Technical Report; IEICE Tech. Rep.•Aug 2, 2018•0 citations

High-Resolution Digital SQUID Magnetometer using Sub-Flux Quantum Feedback

Hiroaki Myoren, Kosuke Okabe, Ryo Matsunawa +3 more

Abstract Digital SQUIDs with the single flux quantum (SFQ) feedback have attracted much attention because of the feasibility of realizing a wide dynamic range and high slew rate for digital magnetometers. In order to realize higher resolution, we have studied a digital SQUID with sub-flux quantum feedback. Combining the sub-flux quantum feedback to a feedback loop and the direct SFQ feedback to a main loop triggered by carry SFQ pulses from an up/down counter. In this study, we discuss the method of multi-flux quantum generation and compact design of the SFQ up/down counter for high-speed operation of the digital SQUID magnetometer.

Journal of Physics Conference Series•Jun 1, 2020•0 citations

Design and Magnetic Field Noise of Magnetometer Using Digital SQUID With Subflux Quantum Feedback

Hiroaki Myoren, Kouhei Takatoku, Masato Naruse +1 more

Digital superconducting quantum interference devices (SQUIDs) based on single-flux quantum (SFQ) logic have attractive characteristics such as wide dynamic ranges and high slew rates. However, the resolution of a typical digital SQUID is limited by SFQ feedback. To realize lower magnetic field noise by magnetometers using digital SQUIDs, we have adopted two feedback combinations: one, utilizing the SFQ input/output for a main loop and the other, using a mutually coupled loop. The main loop receives direct Φ0feedback and subflux quantum feedback Φ0/n, where n is an integer from the mutually coupled loop. The flux resolution for the digital SQUID shows improvement with increasing n and reaches below 40 mΦ0at n = 210; however, the slew rate decreases with increasing n and reaches 1.22 × 106Φ0/s at fc= 1.25 GHz and n = 210. For a magnetometer using a digital SQUID with a pickup loop, we confirmed a magnetic field noise of less than 100 fT/√Hz with a signal bandwidth of 1 MHz for operation frequency fcof 20 GHz.

IEEE Transactions on Applied Superconductivity•May 20, 2016•7 citations
Abstract Digital SQUIDs with the single flux quantum (SFQ) feedback have attracted much attention because of the feasibility of realizing a wide dynamic range and high slew rate for digital magnetometers. In order to realize higher resolution, we have studied a digital SQUID with sub-flux quantum feedback. Combining the sub-flux quantum feedback to a feedback loop and the direct SFQ feedback to a main loop triggered by carry SFQ pulses from an up/down counter. In this study, we discuss the method of multi-flux quantum generation and compact design of the SFQ up/down counter for high-speed operation of the digital SQUID magnetometer.
Digital superconducting quantum interference devices (SQUIDs) based on single-flux quantum (SFQ) logic have attractive characteristics such as wide dynamic ranges and high slew rates. However, the resolution of a typical digital SQUID is limited by SFQ feedback. To realize lower magnetic field noise by magnetometers using digital SQUIDs, we have adopted two feedback combinations: one, utilizing the SFQ input/output for a main loop and the other, using a mutually coupled loop. The main loop receives direct Φ0feedback and subflux quantum feedback Φ0/n, where n is an integer from the mutually coupled loop. The flux resolution for the digital SQUID shows improvement with increasing n and reaches below 40 mΦ0at n = 210; however, the slew rate decreases with increasing n and reaches 1.22 × 106Φ0/s at fc= 1.25 GHz and n = 210. For a magnetometer using a digital SQUID with a pickup loop, we confirmed a magnetic field noise of less than 100 fT/√Hz with a signal bandwidth of 1 MHz for operation frequency fcof 20 GHz.