Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

3D Microwave Cavity for Qubit Measurement

С. А. Новиков, V. Zaretskey, Baladitya Suri, Z. Kim, B. S. Palmer, F. C. Wellstood

Published Feb 28, 2012• 0 citations
OpenAlex

Related papers

Design of a Tunable 3D Microwave Cavity for Use in Coupling to Quantum Superconducting Circuits

C.J. Ballard, Rangga P. Budoyo, Kristen Voigt +4 more

Bulletin of the American Physical Society•Mar 5, 2015•0 citations

Fluxonium Qubit in a 3D Cavity: Measurement and Analysis

K. Geerlings, Ioan M. Pop, Nicholas A. Masluk +4 more

Bulletin of the American Physical Society•Mar 18, 2013•1 citation

Coupling of three-spin qubits to microwave cavities

Maximilian Russ

Bulletin of the American Physical Society•Mar 16, 2017•0 citations

Reducing surface loss in 3D microwave copper cavities for superconducting transmon qubits

Daniela F. Bogorin, Matthew Ware, Douglas McClure +2 more

The recent implementation of three-dimensional microwave cavities coupled to superconducting transmon qubits has led to dramatic improvements in qubit coherence times [1]. Besides the superconducting aluminum cavities that have been used in many such measurements, other recent experiments have utilized copper cavities [2] with coherence times now approaching 0.1 ms. We are investigating the effects on the quality factor for three-dimensional copper cavities that have the cavity-wall surfaces electropolished and coated with a superconducting tin layer. The copper base provides a good path for thermalizing the cavity walls and qubit chip, while the surface treatment reduces the microwave loss. We have measured a superconducting transmon qubit in such a cavity and we report our low-temperature coherence results on the same qubit and cavity measured in two different labs.

IEEE International Superconductive Electronics Conference (ISEC)•Jul 1, 2013•3 citations

Simulation and Measurement of the Vacuum Rabi Coupling g in a 3D Transmon System

Jinsu Son, Gahyun Choi, Taewan Noh +9 more

A transmon qubit in the 3-dimensional microwave cavity is a versatile system for various circuit QED experiments. We have performed numerical calculations of the vacuum Rabi coupling g in 3D transmon circuit QED system, and compared the values with the experimental measurements. We used COMSOL Multiphysics RF package with an appropriate model to efficiently calculate the coupling strength. The calculation agrees with the measurement within a few percents in simple cases. Depending on the position of the qubit in the cavity, we calculated the coupling strengths to different eigenmodes. We compared our result for the fundamental mode (TE101) and a higher mode (TE201) with the experiment by changing the qubit position, as shown in Fig. 2. This simulation and characterization enable efficient design methods for future 3D circuit QED experiments. We confirm that we can design and predict the qubit coupling to the cavity modes with enough accuracy in 3D circuit QED system.

IEEE International Superconductive Electronics Conference (ISEC)•Jul 1, 2019•0 citations

Fast tuning of a high Q microwave cavity for qubit coupling.

Martin Sandberg, Christopher M. Wilson, Fredrik Persson +4 more

Bulletin of the American Physical Society•Mar 12, 2008•0 citations
The recent implementation of three-dimensional microwave cavities coupled to superconducting transmon qubits has led to dramatic improvements in qubit coherence times [1]. Besides the superconducting aluminum cavities that have been used in many such measurements, other recent experiments have utilized copper cavities [2] with coherence times now approaching 0.1 ms. We are investigating the effects on the quality factor for three-dimensional copper cavities that have the cavity-wall surfaces electropolished and coated with a superconducting tin layer. The copper base provides a good path for thermalizing the cavity walls and qubit chip, while the surface treatment reduces the microwave loss. We have measured a superconducting transmon qubit in such a cavity and we report our low-temperature coherence results on the same qubit and cavity measured in two different labs.
A transmon qubit in the 3-dimensional microwave cavity is a versatile system for various circuit QED experiments. We have performed numerical calculations of the vacuum Rabi coupling g in 3D transmon circuit QED system, and compared the values with the experimental measurements. We used COMSOL Multiphysics RF package with an appropriate model to efficiently calculate the coupling strength. The calculation agrees with the measurement within a few percents in simple cases. Depending on the position of the qubit in the cavity, we calculated the coupling strengths to different eigenmodes. We compared our result for the fundamental mode (TE101) and a higher mode (TE201) with the experiment by changing the qubit position, as shown in Fig. 2. This simulation and characterization enable efficient design methods for future 3D circuit QED experiments. We confirm that we can design and predict the qubit coupling to the cavity modes with enough accuracy in 3D circuit QED system.